Survival rates of resin-bonded, glass fiber-reinforced composite fixed partial dentures with a mean follow-up of 42 months: A pilot study

被引:116
|
作者
Vallittu, PK [1 ]
机构
[1] Univ Turku, Inst Dent, Dept Prosthet Dent & Biomat Res, SF-20500 Turku, Finland
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2004年 / 91卷 / 03期
关键词
D O I
10.1016/j.prosdent.2004.01.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Although short-term clinical data exist for resin-bonded, glass fiber-reinforced composite fixed partial dentures (FPDs), long-term data are needed. Purpose. The survival rates of 29 resin-bonded, glass fiber-reinforced composite fixed partial dentures were evaluated in this clinical study for periods Of LIP to 42 months. Material and methods. FPDs were fabricated to replace I to 3 missing maxillary or mandibular teeth of 29 patients not able to be treated with conventional FPDs. Originally, there were 37 patients (the drop-out rate was 22%). The FPDs were retained with wings, inlays, complete coverage crowns, or combinations of these that were bonded to tooth structure. The FPD frameworks were made of continuous unidirectional E-glass fibers with a multiphase polymer matrix and light-polymerized particulate composite veneer. The patients were recalled for examinations, where a general dental examination was performed, I to 3 times per year for up to 63 months (minimum 24 months, mean 42 months). Partial or complete total debonding of the FPD or the framework fracture was considered a treatment failure. The data were analyzed with the Kaplan-Meier survival test (alpha = .05). Results. Two resin frameworks fractured, and 3 frameworks were debonded. Kaplan-Meier survival probability at 63 months was 75%. Three of the failed FPDs were rebonded or repaired in situ, producing a functional survival rate of 93% after rebonding or repairing (mean survival time was 55 months). Conclusion. The results of this clinical study of 29 prostheses suggest that glass fiber-reinforced FPDs may be a possible alternative to cast metal resin-bonded FPDs. These restorations were successfully used as multiple-unit prostheses that employed a variety of abutment tooth preparation designs.
引用
收藏
页码:241 / 246
页数:6
相关论文
共 45 条
  • [31] 6-mm-long implants loaded with fiber-reinforced composite resin-bonded fixed prostheses (FRCRBFDPs). A 5-year prospective study
    Rossi, Fabio
    Lang, Niklaus P.
    Ricci, Emanuele
    Ferraioli, Lorenzo
    Marchetti, Claudio
    Botticelli, Daniele
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (12) : 1478 - 1483
  • [32] Retrospective Clinical Study of Single-Retainer Cantilever Anterior and Posterior Glass-Ceramic Resin-Bonded Fixed Dental Prostheses at a Mean Follow-up of 6 Years
    Sailer, Irena
    Bonani, Tom
    Brodbeck, Urs
    Haemmerle, Christoph Hans Franz
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2013, 26 (05) : 443 - 450
  • [33] Randomized clinical trial on single retainer all-ceramic resin-bonded fixed partial dentures: Influence of the bonding system after up to 55 months
    Sasse, Martin
    Eschbach, Stephanie
    Kern, Matthias
    JOURNAL OF DENTISTRY, 2012, 40 (09) : 783 - 786
  • [34] Fiber-reinforced composite or zirconia in cantilever fixed dental prosthesis? 36-month follow-up clinical study
    Kasem, Ammar T.
    Tribst, Joao Paulo M.
    Abo-Madina, Manal
    Al-Zordk, Walid
    JOURNAL OF DENTISTRY, 2025, 156
  • [35] FIBER-REINFORCED COMPOSITE FIXED DENTAL PROSTHESES IN THE ANTERIOR AREA: A 4.5-YEAR FOLLOW-UP
    Frese, Cornelia
    Schiller, Petra
    Staehle, Hans Joerg
    Wolff, Diana
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (02): : 143 - 149
  • [36] Effect of Different Design Preparations on the Flexural and Fracture Strength of Fiber-Reinforced Composite Fixed Partial Dentures: An In Vitro Study
    Kumar, Gulshan
    Jain, Veena
    Pandey, R. K.
    Gadwal, Manju
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (01): : 57 - 63
  • [38] Clinical Survival of Indirect, Anterior Surface-Retained Fiber-Reinforced Composite Fixed Dental Prosthesis: Up to 3-Year follow-up
    Aktas, Guliz
    Burduroglu, Defne
    Guncu, Mustafa Baris
    Keyf, Filiz
    Oezcan, Mutlu
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2019, 27 (02): : 90 - 94
  • [39] Influence of Retainer Design on Two-unit Cantilever Resin-bonded Glass Fiber Reinforced Composite Fixed Dental Prostheses: An In Vitro and Finite Element Analysis Study
    Keulemans, Filip
    De Jager, Nike
    Kleverlaan, Cornelis J.
    Feilzer, Albert J.
    JOURNAL OF ADHESIVE DENTISTRY, 2008, 10 (05): : 355 - 364
  • [40] Pilot study of unidirectional E-glass fibre-reinforced composite resin splints: Up to 4.5-year clinical follow-up
    Kumbuloglu, Ovul
    Saracoglu, Ahmet
    Ozcan, Mutlu
    JOURNAL OF DENTISTRY, 2011, 39 (12) : 871 - 877