Stent thrombosis after successful sirolimus-eluting stent implantation

被引:270
|
作者
Jeremias, A
Sylvia, B
Bridges, J
Kirtane, AJ
Bigelow, B
Pinto, DS
Ho, KKL
Cohen, DJ
Garcia, LA
Cutlip, DE
Carrozza, JP
机构
[1] Beth Israel Deaconess Med Ctr, Sect Intervent Cardiol, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
关键词
revascularization; thrombosis; stents;
D O I
10.1161/01.CIR.0000127105.99982.21
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Stent thrombosis (ST) is a rare but devastating complication of coronary stent implantation, occurring in 0.5% to 1.9% of patients with bare metal stents. The incidence of ST with drug-eluting stents is less well studied, particularly among patients outside of clinical trials. Methods and Results-The aim of this study was to evaluate the incidence and potential risk factors for ST in patients receiving sirolimus-eluting stents (SES) in the "real world" after commercial release in the United States in April 2003. All 652 patients who underwent SES implantation (776 lesions treated) at our institution between April and October 2003 were followed up prospectively after the procedure (median follow-up 100 days). During that period, 7 patients (1.1%, 95% CI 0.4% to 2.2%) developed ST within a range of 2 to 13 days, and 1 patient had an ST-elevation myocardial infarction on day 39 with evidence of thrombus within the SES at angiography. Patients with an ST had significantly smaller final nominal balloon diameters (2.75 versus 3.00 mm, P = 0.04), and in 4 (57%) of the 7 patients with ST versus 1.7% of patients without ST (P < 0.001), antiplatelet therapy had been discontinued after the procedure. Among the ST patients, 1 died and 5 had myocardial infarctions. Conclusions-In this single-center experience, the incidence of ST after SES implantation was approximate to 1%, which is within the expected range of bare metal stents. The discontinuation of antiplatelet therapy was strongly associated with the development of ST in this patient population.
引用
收藏
页码:1930 / 1932
页数:3
相关论文
共 50 条
  • [31] Frequency, predictors and outcome of stent fracture after sirolimus-eluting stent implantation
    Umeda, Hisashi
    Gochi, Tomoko
    Iwase, Mitsunori
    Izawa, Hideo
    Shimizu, Takeshi
    Ishiki, Ryoji
    Inagaki, Haruo
    Toyama, Junji
    Yokota, Mitsuhiro
    Murohara, Toyoaki
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 133 (03) : 321 - 326
  • [32] Is coronary stent fracture after sirolimus-eluting stent implantation an adverse event?
    Nishibori, Y.
    Fujita, H.
    Matsuo, K.
    Nakanishi, N.
    Shiono, Y.
    Yamaguchi, S.
    Matsuo, A.
    Inoue, K.
    Tanaka, T.
    Kitamura, M.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (8B): : 10C - 11C
  • [33] Is coronary stent fracture after sirolimus-eluting stent implantation an adverse event?
    Nishibori, Yoshiharu
    Fujita, Hiroshi
    Matsuo, Akiko
    Shiono, Yasutsugu
    Matsuo, Kiyonari
    Nakanishi, Naohiko
    Yamaguchi, Shin-ichiro
    Inoue, Keiji
    Tanaka, Tetsuya
    Kitamura, Makoto
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : B40 - B40
  • [34] Sirolimus-eluting stent implantation for unselected in-stent restenosis
    Cho, KH
    Jeong, YS
    Kim, SM
    Kim, DI
    Kim, DS
    Kim, KB
    Kim, KS
    Hur, SH
    Kim, YJ
    Park, JS
    Shim, BS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (8A): : 44A - 44A
  • [35] Very Late Stent Thrombosis 42 Months after Implantation of Sirolimus-Eluting Stent and Discontinuation of Antiplatelet Therapy
    Sibbing, Dirk
    Laugwitz, Karl-Ludwig
    Bott-Fluegel, Lorenz
    Pache, Juergen
    [J]. CASE REPORTS IN MEDICINE, 2009, 2009
  • [36] Predictors of Local Persistent Hypercoagulability After Sirolimus-eluting Stent Implantation: Implication for Correlates of Late Stent Thrombosis
    Yamaguchi, Koji
    Wakatsuki, Tetsuzo
    Niki, Toshiyuki
    Kusunose, Kenya
    Koshiba, Kunihiko
    Yagi, Syusuke
    Taketani, Yoshio
    Iwase, Takashi
    Tomita, Noriko
    Yamada, Hirotsugu
    Soeki, Takeshi
    Akaike, Masashi
    Sata, Masataka
    [J]. CIRCULATION, 2009, 120 (18) : S992 - S993
  • [37] Intravascular Ultrasound Comparison of with Early, Late, and Very Late Stent Thrombosis After Sirolimus-Eluting Stent Implantation
    Kume, Teruyoshi
    Waseda, Katsuhisa
    Kozuma, Ken
    Aizawa, Tadanori
    Mitsudo, Kazuaki
    Miyazaki, Shinichi
    Yamaguchi, Tetsu
    Isshiki, Takaaki
    Kimura, Takeshi
    Fitzgerald, Peter J.
    Honda, Yasuhiro
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (13) : B10 - B10
  • [38] In-stent restenosis after sirolimus-eluting stent implantation is related to coronary stent fracture
    Lee, S. Y.
    Kim, M. H.
    Ahn, C. M.
    Kim, J. S.
    Choi, D. H.
    Jang, Y. S.
    Chung, N. S.
    Min, P. K.
    Yoon, Y. W.
    Hong, B. K.
    [J]. CIRCULATION, 2007, 116 (16) : 467 - 468
  • [39] Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis
    Fujii, K
    Mintz, GS
    Kobayashi, Y
    Carlier, SG
    Takebayashi, H
    Yasuda, T
    Moussa, I
    Dangas, G
    Mehran, R
    Lansky, AJ
    Reyes, A
    Kreps, E
    Collins, M
    Colombo, A
    Stone, GW
    Teirstein, PS
    Leon, MB
    Moses, JW
    [J]. CIRCULATION, 2004, 109 (09) : 1085 - 1088
  • [40] Risk of stent thrombosis after sirolimus or paclitaxel eluting coronary stent implantation
    Moreno, Raul
    Fernandez, Cristina
    Sanchez-Recalde, Angel
    Calvo, Luis
    Galeote, Guillermo
    Sanchez-Aquino, Rosa
    Lopez-Sendon, Jose-Luis
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2007, 64 (01) : 110 - 112