Long-Term Follow-Up of a Novel Implantable Programmable Infusion Pump

被引:13
|
作者
Rauck, Richard [1 ]
Deer, Timothy [2 ]
Rosen, Steven [3 ]
Padda, Gurpreet [4 ]
Barsa, John [5 ]
Dunbar, Elmer [6 ]
Dwarakanath, Gopala [7 ]
机构
[1] Wake Forest Univ Hlth Sci, Winston Salem, NC USA
[2] Ctr Pain Relief, Charleston, WV USA
[3] Fox Chase Pain Management Associates, Jenkintown, PA USA
[4] Ctr Intervent Pain Management, St Louis, MO USA
[5] Pain Inst Tampa, Tampa, FL USA
[6] Pain Control Network, Louisville, KY USA
[7] Lowell Gen Hosp, Lowell, MA USA
来源
NEUROMODULATION | 2013年 / 16卷 / 02期
关键词
Back pain; chronic pain; implantable infusion pump; intractable pain; morphine; INTRATHECAL DRUG INFUSION; CHRONIC PAIN; DELIVERY; MORPHINE; MANAGEMENT; THERAPY; SYSTEMS; MASSES;
D O I
10.1111/j.1525-1403.2012.00515.x
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives The Prometra (R) Programmable Pump System (Flowonix Medical, Inc., Mt. Olive, NJ, USA) is designed for continuous intrathecal administration of morphine sulfate to treat chronic intractable pain. As a follow-up to a previous report on acute six-month data, this study evaluated the efficacy of treatment at one year and the accuracy of drug delivery throughout the study (average of 2.5 years, range 03.6 years). Methods Accuracy of drug delivery was determined as the ratio of delivered-to-programmed drug volume at scheduled refill visits (monthly for the first six months and every three months thereafter). Efficacy was assessed at 12 months using the visual analog and numeric rating scales and the Oswestry Disability Index. Safety was assessed by documenting adverse events and device complications throughout the study. Results The mean accuracy of the Prometra pump was 97.9% and was comparable to the reported accuracy at one to six months (97.1%). After 12 months, 68% of the remaining subjects reported improvement in disability scores from baseline and more than 75% of the remaining subjects reported decreases in pain from baseline. The incidence rates of adverse events and device complications were similar to previous reports for this therapy. Conclusions The Prometra pump demonstrated accurate drug delivery throughout the study and provides an effective and safe means for intrathecal administration of morphine sulfate for treatment of chronic intractable pain.
引用
收藏
页码:163 / 167
页数:5
相关论文
共 50 条
  • [41] Long-term follow-up of patients with cardiac sarcoidosis and implantable cardioverter-defibrillators
    Betensky, Brian P.
    Tschabrunn, Cory M.
    Zado, Erica S.
    Goldberg, Lee R.
    Marchlinski, Francis E.
    Garcia, Fermin C.
    Cooper, Joshua M.
    HEART RHYTHM, 2012, 9 (06) : 884 - 891
  • [42] Long-term follow-up of paediatric patients with a subcutaneous implantable cardioverter-defibrillator
    Van der Stuijt, W.
    De Wilde, K. C.
    Baalman, S. W. E.
    Quast, A. B. E.
    Blom, N. A.
    Wilde, A. A. M.
    Knops, R. E.
    EUROPEAN HEART JOURNAL, 2020, 41 : 3209 - 3209
  • [43] Long-term follow-up of implantable cardioverter-defibrillators in children: Indications and outcomes
    Kwiatkowska, Joanna
    Budrejko, Szymon
    Wasicionek, Marek
    Meyer-Szary, Jaroslaw
    Lubinski, Andrzej
    Kempa, Maciej
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2020, 29 (01): : 123 - 133
  • [44] Long-term follow-up of primary and secondary prevention implantable cardioverter defibrillator patients
    van Welsenes, Guido H.
    van Rees, Johannes B.
    Borleffs, C. Jan Willem
    Cannegieter, Suzanne C.
    Bax, Jeroen J.
    van Erven, Lieselot
    Schalij, Martin J.
    EUROPACE, 2011, 13 (03): : 389 - 394
  • [45] Long-term follow-up of patients with indication for a implantable defibrillator for primary prevention of death
    Hadid, Claudio
    Avellana, Patricia
    Di Toro, Dario
    Fernandez Gomez, Claudia
    Visser, Miguel
    Prieto, Noemi
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2008, 90 (05) : 339 - 344
  • [46] Long-term follow-up of implantable cardioverter-defibrillators in Short QT syndrome
    El-Battrawy, Ibrahim
    Besler, Johanna
    Ansari, Uzair
    Liebe, Volker
    Schimpf, Rainer
    Tueluemen, Erol
    Rudic, Boris
    Lang, Siegfried
    Odening, Katja
    Cyganek, Lukas
    Wolpert, Christian
    Zhou, Xiaobo
    Borggrefe, Martin
    Akin, Ibrahim
    CLINICAL RESEARCH IN CARDIOLOGY, 2019, 108 (10) : 1140 - 1146
  • [47] Telemetric homemonitoring for patients with implantable defibrillators: experiences during long-term follow-up
    Dorszewski, A
    Schirdewahn, P
    Piorkowski, C
    Gerds-Li, JH
    Weiss, E
    Wetzel, U
    Kottkamp, H
    Hindricks, G
    EUROPEAN HEART JOURNAL, 2004, 25 : 167 - 167
  • [48] Long-Term Follow-up of a Novel Anastomotic Device in a Canine Model
    Park, Adrian
    Lee, Tommy H.
    Kavic, Stephen M.
    SURGICAL INNOVATION, 2014, 21 (02) : 198 - 203
  • [49] LONG-TERM FOLLOW-UP AFTER SPONTANEOUS CONTRAST EXTRAVASATION DURING INFUSION UROGRAMS
    WALTER, E
    WOLF, KJ
    GREHN, S
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1979, 131 (01): : 17 - 23
  • [50] Long-Term Follow-up of Off-Pump and On-Pump Coronary Artery Bypass Grafting
    Raja, Shahzad G.
    Benedetto, Umberto
    Chudasama, Dimple
    Daley, Siobhan
    Husain, Mubassher
    Amrani, Mohamed
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2014, 9 (02) : 122 - 129