Long-Term Follow-Up of a Novel Implantable Programmable Infusion Pump

被引:13
|
作者
Rauck, Richard [1 ]
Deer, Timothy [2 ]
Rosen, Steven [3 ]
Padda, Gurpreet [4 ]
Barsa, John [5 ]
Dunbar, Elmer [6 ]
Dwarakanath, Gopala [7 ]
机构
[1] Wake Forest Univ Hlth Sci, Winston Salem, NC USA
[2] Ctr Pain Relief, Charleston, WV USA
[3] Fox Chase Pain Management Associates, Jenkintown, PA USA
[4] Ctr Intervent Pain Management, St Louis, MO USA
[5] Pain Inst Tampa, Tampa, FL USA
[6] Pain Control Network, Louisville, KY USA
[7] Lowell Gen Hosp, Lowell, MA USA
来源
NEUROMODULATION | 2013年 / 16卷 / 02期
关键词
Back pain; chronic pain; implantable infusion pump; intractable pain; morphine; INTRATHECAL DRUG INFUSION; CHRONIC PAIN; DELIVERY; MORPHINE; MANAGEMENT; THERAPY; SYSTEMS; MASSES;
D O I
10.1111/j.1525-1403.2012.00515.x
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives The Prometra (R) Programmable Pump System (Flowonix Medical, Inc., Mt. Olive, NJ, USA) is designed for continuous intrathecal administration of morphine sulfate to treat chronic intractable pain. As a follow-up to a previous report on acute six-month data, this study evaluated the efficacy of treatment at one year and the accuracy of drug delivery throughout the study (average of 2.5 years, range 03.6 years). Methods Accuracy of drug delivery was determined as the ratio of delivered-to-programmed drug volume at scheduled refill visits (monthly for the first six months and every three months thereafter). Efficacy was assessed at 12 months using the visual analog and numeric rating scales and the Oswestry Disability Index. Safety was assessed by documenting adverse events and device complications throughout the study. Results The mean accuracy of the Prometra pump was 97.9% and was comparable to the reported accuracy at one to six months (97.1%). After 12 months, 68% of the remaining subjects reported improvement in disability scores from baseline and more than 75% of the remaining subjects reported decreases in pain from baseline. The incidence rates of adverse events and device complications were similar to previous reports for this therapy. Conclusions The Prometra pump demonstrated accurate drug delivery throughout the study and provides an effective and safe means for intrathecal administration of morphine sulfate for treatment of chronic intractable pain.
引用
收藏
页码:163 / 167
页数:5
相关论文
共 50 条
  • [1] Long-Term Follow-Up of a Novel Implantable Programmable Infusion Pump COMMENTS
    Burton, Allen W.
    Turner, Michael
    NEUROMODULATION, 2013, 16 (02): : 167 - 167
  • [2] Long-term follow-up of fluctuating Parkinsonians on apomorphine continuous subcutaneous infusion by PUMP
    Vanderheyden, JEGM
    MOVEMENT DISORDERS, 2005, 20 : S119 - S119
  • [3] AN IMPLANTABLE PUMP FOR LONG-TERM INTRAVASCULAR DRUG INFUSION
    BLACKSHEAR, PJ
    ROHDE, TD
    DORMAN, FD
    BUCHWALD, H
    MEDICAL INSTRUMENTATION, 1981, 15 (04): : 226 - 228
  • [4] DIET AND PUMP-TREATED DIABETES - A LONG-TERM FOLLOW-UP
    CHANTELAU, EA
    BOCKHOLT, M
    LIE, KT
    BROERMANN, C
    SONNENBERG, GE
    BERGER, M
    DIABETES & METABOLISM, 1983, 9 (04): : 277 - 282
  • [5] Long-term follow-up of patients with tetralogy of Fallot and implantable cardioverter defibrillator
    Waldmann, V.
    Bouzeman, A.
    Marquie, C.
    Labombarda, F.
    Koutbi, R.
    Sellal, J. M.
    Fauchier, L.
    Mondoly, P.
    Pasquie, J. L.
    Anselme, F.
    Eschalier, R.
    Iserin, L.
    Thambo, J. B.
    Combes, N.
    Marijon, E.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1368 - 1368
  • [6] Long-term follow-up of patients with tetralogy of Fallot and implantable cardioverter defibrillator
    Waldmann, V
    Bouzeman, A.
    Duthoit, G.
    Koutbi, R.
    Bessiere, F.
    Labombarda, F.
    Marquie, C.
    Gourraud, J. B.
    Ladouceur, M.
    Mondoly, P.
    Sacher, F.
    Iserin, L.
    Thambo, J. B.
    Combes, N.
    Marijon, E.
    EUROPEAN HEART JOURNAL, 2020, 41 : 792 - 792
  • [7] Inappropriate interventions during the long-term follow-up of patients with an implantable defibrillator
    Stuber, Thomas
    Eigenmann, Christa
    Delacretaz, Etienne
    SWISS MEDICAL WEEKLY, 2007, 137 (15-16) : 228 - 233
  • [8] Long-term follow-up of implantable cardioverter, defibrillator therapy for hypertrophic cardiomyopathy
    Jayatilleke, I
    Doolan, A
    Ingles, J
    McGuire, M
    Booth, V
    Richmond, DR
    Semsarian, C
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (09): : 1192 - 1194
  • [9] Implantable cardioverter-defibrillator in Brugada syndrome: Long-term follow-up
    El-Battrawy, Ibrahim
    Roterberg, Gretje
    Liebe, Volker
    Ansari, Uzair
    Lang, Siegfried
    Zhou, Xiaobo
    Borggrefe, Martin
    Akin, Ibrahim
    CLINICAL CARDIOLOGY, 2019, 42 (10) : 958 - 965
  • [10] Gitelman syndrome: novel mutation and long-term follow-up
    Sinha, Aditi
    Lnenicka, Petr
    Basu, Biswanath
    Gulati, Ashima
    Hari, Pankaj
    Bagga, Arvind
    CLINICAL AND EXPERIMENTAL NEPHROLOGY, 2012, 16 (02) : 306 - 309