A multicentre, prospective, randomised comparison of the sliding hip screw with the Medoff sliding screw and side plate for unstable intertrochanteric hip fractures

被引:11
|
作者
McCormack, R. [1 ]
Panagiotopolous, K. [1 ]
Buckley, R. [2 ]
Penner, M. [1 ]
Perey, B. [1 ]
Pate, G. [1 ]
Goetz, T. [1 ]
Piper, M. [1 ]
机构
[1] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[2] Univ Calgary, Calgary, AB, Canada
关键词
Intertrochanteric fracture; Hip screw; Sliding plate; MEDIAL DISPLACEMENT OSTEOTOMY; GAMMA-NAIL; SUBTROCHANTERIC FRACTURES; ANATOMICAL REDUCTION; FEMORAL FRACTURES; FIXATION; FEMUR; COMPRESSION; TRIAL; COMPLICATIONS;
D O I
10.1016/j.injury.2013.06.017
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: This study aimed to compare the dynamic hip screw (DHS) and Medoff sliding plate (MSP) for unstable intertrochanteric hip fractures. Design: A randomised, prospective trial design was used. Setting: The study was undertaken in two level-1 trauma centres and one community hospital. Patients/participants: A total of 163 patients with unstable intertrochanteric hip fractures (Orthopaedic Trauma Association (OTA) 31-A2) were randomised to DHS or MSP. Inclusion and exclusion criteria were designed to focus on isolated unstable intertrochanteric hip fractures in ambulatory patients. Intervention: Randomisation was performed intra-operatively, after placement of a 1358 guide wire. Follow-up assessments were performed at regular intervals for a minimum of 6 months. Main outcome measurements: The primary outcome measure was re-operation rate. The secondary outcome was patient function, evaluated using a validated outcome measure, the Hip Fracture Functional Recovery Score. Tertiary outcomes included: mortality, hospital stay, quality of reduction and malunion rate. Results: A total of 86 patients were randomised to DHS and 77 to MSP. The groups had similar patient demographics, pre-fracture status and in-hospital course. The quality of reduction was the same for each group, but the operative time was longer in the MSP group (61.6 vs. 50.1 min, P = 0.01). The rate of reoperation was low (3/86 in DHS and 2/77 in MSP) with no statistically significant difference. The functional outcomes were the same for both groups, with functional recovery scores at 6 months of 51.0% in the DHS arm and 49.7% in the MSP arm. Conclusions: The two techniques produced similar results for the clinically important outcomes of the need for further surgery and functional status of the patients at 6 months' follow-up. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1904 / 1909
页数:6
相关论文
共 50 条
  • [31] Sliding screw implants for extracapsular hip fractures
    [J]. Mavrogenis, A. F. (afm@otenet.gr), 1600, Begell House Inc. (22):
  • [32] TREATMENT OF INTERTROCHANTERIC HIP FRACTURES WITH A COMPRESSION HIP SCREW AND A NAIL PLATE
    JACOBS, RR
    ARMSTRONG, HJ
    WHITAKER, JH
    PAZELL, J
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1976, 16 (08): : 599 - 603
  • [33] EXPERIENCE WITH A SLIDING SCREW IN INTERTROCHANTERIC FRACTURES
    DAUM, WJ
    BURDGE, RE
    OREILLY, DE
    RAO, AN
    [J]. ORTHOPEDICS, 1979, 2 (06) : 608 - 613
  • [34] THE SLIDING COMPRESSION SCREW - TODAYS BEST ANSWER FOR STABILIZATION OF INTERTROCHANTERIC HIP-FRACTURES
    DOPPELT, SH
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 1980, 11 (03) : 507 - 523
  • [35] Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients
    Kuang-Kai Hsueh
    Chi-Kuang Fang
    Chuan-Mu Chen
    Yu-Ping Su
    Heng-Fei Wu
    Fang-Yao Chiu
    [J]. International Orthopaedics, 2010, 34 : 1273 - 1276
  • [36] Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients
    Hsueh, Kuang-Kai
    Fang, Chi-Kuang
    Chen, Chuan-Mu
    Su, Yu-Ping
    Wu, Heng-Fei
    Chiu, Fang-Yao
    [J]. INTERNATIONAL ORTHOPAEDICS, 2010, 34 (08) : 1273 - 1276
  • [37] THE STABILITY OF INTERTROCHANTERIC FRACTURES TREATED WITH A SLIDING SCREW-PLATE
    FLORES, LA
    HARRINGTON, IJ
    HELLER, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01): : 37 - 40
  • [38] Dual lag screw cephalomedullary nail versus the classic sliding hip screw for the stabilization of intertrochanteric fractures. A prospective randomized study
    Kouvidis, G.
    Sakellariou, V. I.
    Mavrogenis, A. F.
    Stavrakakis, J.
    Kampas, D.
    Galanakis, J.
    Papagelopoulos, P. J.
    Katonis, P.
    [J]. STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2012, 7 (03): : 155 - 162
  • [39] Extramedullary fixation of 569 unstable intertrochanteric fractures -: A randomized multicenter trial of the Medoff sliding plate versus three other screw-plate systems
    Lunsjö, K
    Ceder, L
    Thorngren, KG
    Skytting, B
    Tidermark, J
    Berntson, PO
    Allvin, I
    Norberg, S
    Hjalmars, K
    Larsson, S
    Knebel, R
    Hauggaard, A
    Stigsson, L
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 2001, 72 (02): : 133 - 140
  • [40] The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: A review of 93 cases - Editorial comment
    Bone, LB
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (02): : 328 - 329