An L-lactate Biosensor Based on Printed Organic Inverter Circuitry and with a Tunable Detection Limit

被引:13
|
作者
Nagamine, Kuniaki [1 ]
Mano, Taisei [1 ]
Shiwaku, Rei [1 ]
Furusawa, Hiroyuki [2 ]
Matsui, Hiroyuki [1 ]
Kumaki, Daisuke [1 ]
Tokito, Shizuo [1 ]
机构
[1] Yamagata Univ, Res Ctr Organ Elect ROEL, 4-3-16 Jonan, Yonezawa, Yamagata 9928510, Japan
[2] Yamagata Univ, Grad Sch Sci & Engn, 4-3-16 Jonan, Yonezawa, Yamagata 9928510, Japan
基金
日本科学技术振兴机构;
关键词
printed electronics; organic inverter circuit; biosensor; limit detection; wearable; SKIN; FABRICATION; SENSOR;
D O I
10.18494/SAM.2019.2174
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this study, we showed proof-of-principle experiments to demonstrate a printed organic inverter-circuit-based enzyme sensor with an extended-gate electrode with a lactate oxidase (LOx) and Prussian Blue carbon-graphite ink active area for the first time to inform users of an L-lactate overlimit concentration via a simple integrated electrophoretic display. The two-stage organic inverter circuit exhibited an abrupt shift in output voltage depending on the potentiometric sensor signal imposed on the constant input voltage of the inverter circuit, resulting in a distinct color change of the display connected to the output line of the inverter circuit. The L-lactate concentration limit was tuned by changing the input voltage of the inverter circuit. This new type of wearable biosensor, notifying the user of an overlimit condition, can arbitrarily be tuned by professionals such as medical doctors or sports trainers and would be helpful for users who do not have sufficient knowledge about the detected biomarkers.
引用
收藏
页码:1205 / 1213
页数:9
相关论文
共 50 条
  • [21] An Oxygen-Insensitive biosensor and a biofuel cell device based on FMN L-lactate dehydrogenase
    Cohen, Roy
    Herzallh, Nidaa S.
    Meirovich, Matan M.
    Bachar, Oren
    Frech, Liora
    Cohen, Yifat
    Yehezkeli, Omer
    BIOELECTROCHEMISTRY, 2023, 149
  • [22] Development of L-lactate dehydrogenase biosensor based on porous silicon resonant microcavities as fluorescence enhancers
    Jenie, S. N. Aisyiyah
    Prieto-Simon, Beatriz
    Voelcker, Nicolas H.
    BIOSENSORS & BIOELECTRONICS, 2015, 74 : 637 - 643
  • [23] Dataset on fabrication of an improved L-lactate biosensor based on lactate oxidase/cMWCNT/CuNPs/PANI modified PG electrode
    Dagar, Kusum
    Pundir, C. S.
    DATA IN BRIEF, 2018, 17 : 1163 - 1167
  • [24] ELECTROPOLYMERIZED O-PHENYLENEDIAMINE FILM AS MEANS OF IMMOBILISING LACTATE OXIDASE FOR A L-LACTATE BIOSENSOR
    DEMPSEY, E
    WANG, J
    SMYTH, MR
    TALANTA, 1993, 40 (03) : 445 - 451
  • [25] A novel amperometric biosensor based on gold nanoparticles anchored on reduced graphene oxide for sensitive detection of L-lactate tumor biomarker
    Azzouzi, Sawsen
    Rotariu, Lucian
    Benito, Ana M.
    Maser, Wolfgang K.
    Ben Ali, Mounir
    Bala, Camelia
    BIOSENSORS & BIOELECTRONICS, 2015, 69 : 280 - 286
  • [26] Application of lactate amperometric sol-gel biosensor to sequential injection determination of L-lactate
    Gomes, Sofia Piedade
    Odlozilikova, Martina
    Almeida, M. Gabriela
    Araujo, Alberto N.
    Couto, Cristina M. C. M.
    Montenegro, M. Conceicao B. S. M.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (04) : 1376 - 1381
  • [27] Smartphone-Based and Miniaturized Electrochemical Biosensing System for L-Lactate Detection
    Yu, Qiwen
    Chen, Jing
    Xu, Jingpin
    Chen, Long
    Song, Yanhua
    Xie, Xiaoya
    Jin, Jinjiang
    Liu, Hong
    Liu, Jun
    Zhang, Fengjiang
    Chen, Xing
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (04)
  • [28] Amperometric L-Lactate Biosensor Based upon a Gold Nanoparticles/Reduced Graphene Oxide/Polyallylamine Hydrochloride Modified Screen-Printed Graphite Electrode
    Istrate, Oana-Maria
    Rotariu, Lucian
    Bala, Camelia
    CHEMOSENSORS, 2021, 9 (04)
  • [29] Flow injection analysis of L-lactate in milk and yoghurt by on-line microdialysis and amperometric detection at a disposable biosensor
    Palmisano, F
    Quinto, M
    Rizzi, R
    Zambonin, PG
    ANALYST, 2001, 126 (06) : 866 - 870
  • [30] Smartphone-based enzymatic biosensor for oral fluid L-lactate detection in one minute using confined multilayer paper reflectometry
    Calabria, Donato
    Caliceti, Cristiana
    Zangheri, Martina
    Mirasoli, Mara
    Simoni, Patrizia
    Roda, Aldo