Hemodynamic and morphological vasculature response to a burn monitored using a combined dual-wavelength laser speckle and optical microangiography imaging system

被引:39
|
作者
Qin, Jia [1 ]
Reif, Roberto [1 ]
Zhi, Zhongwei [1 ]
Dziennis, Suzan [1 ]
Wang, Ruikang [1 ]
机构
[1] Univ Washington, Ctr Bioengn, Seattle, WA 98195 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2012年 / 3卷 / 03期
基金
美国国家卫生研究院;
关键词
CEREBRAL BLOOD-FLOW; IN-VIVO; CAPILLARY RECRUITMENT; COHERENCE TOMOGRAPHY; REACTIVE HYPEREMIA; PHOTOACOUSTIC MICROSCOPY; TISSUE BEDS; HUMAN SKIN; OXYGENATION; HYPOXIA;
D O I
10.1364/BOE.3.000455
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A multi-functional imaging system capable of determining relative changes in blood flow, hemoglobin concentration, and morphological features of the blood vasculature is demonstrated. The system combines two non-invasive imaging techniques, a dual-wavelength laser speckle contrast imaging (2-LSI) and an optical microangiography (OMAG) system. 2-LSI is used to monitor the changes in the dynamic blood flow and the changes in the concentration of oxygenated (HbO), deoxygenated (Hb) and total hemoglobin (HbT). The OMAG system is used to acquire high resolution images of the functional blood vessel network. The vessel area density (VAD) is used to quantify the blood vessel network morphology, specifically the capillary recruitment. The proposed multi-functional system is employed to assess the blood perfusion status from a mouse pinna before and immediately after a burn injury. To our knowledge, this is the first non-invasive, non-contact and multifunctional imaging modality that can simultaneously measure variations of several blood perfusion parameters. (c) 2012 Optical Society of America
引用
收藏
页码:455 / 466
页数:12
相关论文
共 50 条
  • [41] ZEMAX Simulation Methodof Laser Tracing System Using a Dual-Wavelength Method to Compensate for the Refractive Index of Air
    Chen Hongfang
    Tang Liang
    Shi Zhaoyao
    Song Huixu
    Sun Yanqiang
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2019, 46 (01):
  • [42] DUAL-WAVELENGTH PICOSECOND OPTICAL PULSE GENERATION USING AN ACTIVELY MODE-LOCKED MULTICHANNEL GRATING CAVITY LASER
    ZHU, B
    NYAIRO, KO
    WHITE, IH
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1994, 6 (03) : 348 - 351
  • [43] Frequency multiplication of microwave signals by sideband optical injection locking using a monolithic dual-wavelength DFB laser device
    Laperle, C
    Svilans, M
    Poirier, M
    Têtu, M
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1999, 47 (07) : 1219 - 1224
  • [44] Closely spaced dual-wavelength fiber laser using an ultranarrow bandwidth optical filter for low radio frequency generation
    Ahmad, H.
    Razak, N. F.
    Zulkifli, M. Z.
    Muhammad, F. D.
    Munajat, Y.
    Harun, S. W.
    APPLIED OPTICS, 2014, 53 (19) : 4123 - 4127
  • [45] Dual-wavelength band spectroscopic optical frequency domain imaging using plasmon-resonant scattering in metallic nanoparticles
    Kim, Tae Shik
    Jang, Sun-Joo
    Oh, Nuri
    Kim, Yongjoo
    Park, Taejin
    Park, Jiho
    Oh, Wang-Yuhl
    OPTICS LETTERS, 2014, 39 (10) : 3082 - 3085
  • [46] Using a fast dual-wavelength imaging ellipsometric system to measure the flow thickness profile of an oil thin film
    Kuo, Chih-Wei
    Han, Chien-Yuan
    Jhou, Jhe-Yi
    Peng, Zeng-Yi
    APPLIED SURFACE SCIENCE, 2017, 421 : 465 - 470
  • [47] Achieving High Stability of Dual-Wavelength U-Shaped Laser in the C-Band Using Optical Feedback
    Far Brusatori, Monica
    Klein, Holger N.
    Volet, Nicolas
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2023, 35 (10) : 573 - 576
  • [48] A highly stable and switchable dual-wavelength laser using coupled microfiber Mach-Zehnder interferometer as an optical filter
    Jasim, A. A.
    Ahmad, H.
    OPTICS AND LASER TECHNOLOGY, 2017, 97 : 12 - 19
  • [49] Tunable optical microwave generation using self-injection locked monolithic dual-wavelength amplified feedback laser
    Pan, Biwei
    Lu, Dan
    Sun, Yu
    Yu, Liqiang
    Zhang, Limeng
    Zhao, Lingjuan
    OPTICS LETTERS, 2014, 39 (22) : 6395 - 6398
  • [50] Quantitative assessment of graded burn wounds using a commercial and research grade laser speckle imaging (LSI) system
    Ponticorvo, A.
    Rowland, R.
    Yang, B.
    Lertsakdadet, B.
    Crouzet, C.
    Bernal, N.
    Choi, B.
    Durkin, A. J.
    PHOTONICS IN DERMATOLOGY AND PLASTIC SURGERY, 2017, 10037