Haptic Edge Sharpness Perception with a Contact Location Display

被引:0
|
作者
Park, Jaeyoung [1 ]
Doxon, Andrew J. [2 ]
Provancher, William R. [2 ]
Johnson, David E. [3 ]
Tan, Hong Z. [1 ]
机构
[1] Purdue Univ, Hapt Interface Res Lab, W Lafayette, IN 47907 USA
[2] Univ Utah, Dept Mech Engn, Salt Lake City, UT 84112 USA
[3] Univ Utah, Sch Comp, Salt Lake City, UT 84112 USA
基金
美国国家科学基金会;
关键词
Contact location display; edge sharpness perception; curvature discrimination; effect of contact element size; CURVATURE; MECHANISMS; DISCRIMINATION; INFORMATION; ROUGHNESS; FEEDBACK; TEXTURE;
D O I
10.1109/ToH.2012.14
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The effect of contact location information on virtual edge perception was investigated in two experiments. In Experiment 1, participants discriminated edge sharpness under force-alone and force-plus-contact-location conditions using a 4.8 mm radius contact roller. Virtual objects were 2D profiles of edges with two adjoining surfaces. For both conditions, the Just Noticeable Difference (JND) in change of edge radius increased from 2.3 to 7.4 mm as edge radii increased from 2.5 to 20.0 mm; there was no significant difference between the two conditions. A follow-up experiment with contact location alone resulted in higher edge sharpness JNDs. In Experiment 2, the same edge sharpness discrimination task was performed using a smaller contact roller (R = 1.5 mm) to investigate the effect of roller size. The JNDs for the smaller roller were not statistically significant from those of the larger roller. Our results suggest that 1) contact location cues alone are capable of conveying edge sharpness information, but that force cues are dominant when both types of cues are available; and 2) the radius of the contact roller does not significantly affect the user's ability to discriminate edge sharpness, indicating that the participants could use the changes in contact location to judge curvature.
引用
收藏
页码:323 / 331
页数:9
相关论文
共 50 条
  • [21] A Method of mobile display(OLED/LCD) sharpness assessment through the perceptual brightness and edge characteristic of display and image
    Lee, Min Woo
    Yeom, Jee Young
    Kim, Jong Ho
    Park, Hyun Hee
    Jang, Seul Ki
    DIGITAL PHOTOGRAPHY X, 2014, 9023
  • [22] Perception of a Haptic Jamming Display: Just Noticeable Differences in Stiffness and Geometry
    Genecov, Adam M.
    Stanley, Andrew A.
    Okamura, Allison M.
    2014 IEEE HAPTICS SYMPOSIUM (HAPTICS), 2014, : 333 - 338
  • [23] Justification Of Edge Sharpness
    Lebedev, Anatoly Timofeevich
    Lebedev, Pavel Anatolyevich
    Maryin, Nikolay Aleksandrovich
    Maryin, Alexander Nikolaevich
    Chernovolov, Vasiliy Aleksandrovich
    RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES, 2018, 9 (06): : 720 - 725
  • [24] Haptic Display of Rigid Body Contact Using Generalized Penetration Depth
    Wu, Jun
    Wang, Dangxiao
    Zhang, Yuru
    INTELLIGENT ROBOTICS AND APPLICATIONS, PT I: ICIRA 2011, 2011, 7101 : 532 - 541
  • [25] OLED display sharpness with diffuser
    Cok, Ronald S.
    2008 SID INTERNATIONAL SYMPOSIUM, DIGEST OF TECHNICAL PAPERS, VOL XXXIX, BOOKS I-III, 2008, 39 : 1978 - 1980
  • [26] Haptic interaction to realize collision and contact of dental tools in double-channel haptic display system
    Liu, Guan-Yang
    Zhang, Yu-Ru
    Wang, Yu
    Wang, Dang-Xiao
    Xitong Fangzhen Xuebao / Journal of System Simulation, 2007, 19 (20): : 4711 - 4715
  • [27] A review of technologies for sensing contact location on the surface of a display
    Walker, Geoff
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2012, 20 (08) : 413 - 440
  • [28] Effects of the Alignment Between a Haptic Device and Visual Display on the Perception of Object Softness
    Widmer, Antoine
    Hu, Yaoping
    IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS PART A-SYSTEMS AND HUMANS, 2010, 40 (06): : 1146 - 1155
  • [29] A Fuzzy Rule-Based Haptic Perception Model for Automotive Vibrotactile Display
    Dutu, Liviu-Cristian
    Mauris, Gilles
    Bolon, Philippe
    Dabic, Stephanie
    Tissot, Jean-Marc
    INFORMATION PROCESSING AND MANAGEMENT OF UNCERTAINTY IN KNOWLEDGE-BASED SYSTEMS, PT II, 2014, 443 : 576 - 585
  • [30] Six-degree-of-freedom haptic display using localized contact computations
    Kim, YJ
    Otaduy, MA
    Lin, MC
    Manocha, D
    10TH SYMPOSIUM ON HAPTIC INTERFACES FOR VIRTUAL ENVIRONMENT AND TELEOPERATOR SYSTEMS, PROCEEDINGS, 2002, : 209 - 216