Rapid Fabrication of Poly(methyl methacrylate) Devices for Lab-on-a-Chip Applications Using Acetic Acid and UV Treatment

被引:42
|
作者
Trinh, Kieu The Loan [2 ]
Thai, Duc Anh [1 ]
Chae, Woo Ri [3 ]
Lee, Nae Yoon [1 ]
机构
[1] Gachon Univ, Dept BioNano Technol, Seongnam Si 13120, Gyeonggi Do, South Korea
[2] Gachon Univ, Dept Ind Environm Engn, Seongnam Si 13120, Gyeonggi Do, South Korea
[3] Gachon Univ, BioNano Res Inst, Seongnam Si 13120, Gyeonggi Do, South Korea
来源
ACS OMEGA | 2020年 / 5卷 / 28期
基金
新加坡国家研究基金会;
关键词
POLYMERASE-CHAIN-REACTION; BONDING METHOD; SOLVENT; MICROELECTRODES; TEMPERATURE; MICRODEVICE; BIOSENSOR; RESPONSES;
D O I
10.1021/acsomega.0c01770
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the present study, we introduce a new approach for rapid bonding of poly(methyl methacrylate) (PMMA)-based microdevices using an acetic acid solvent with the assistance of UV irradiation. For the anticipated mechanism, acetic acid and UV irradiation induced free radicals on the PMMA surfaces, and acrylate monomers subsequently formed cross-links to create a permanent bonding between the PMMA substrates. PMMA devices effectively bonded within 30 s at a low pressure using clamps, and a clogging-free microchannel was achieved with the optimized 50% acetic acid. For surface characterizations, contact angle measurements and bonding performance analyses were conducted using predetermined acetic acid concentrations to optimize bonding conditions. In addition, the highest bond strength of bonded PMMA was approximately 11.75 MPa, which has not been reported before in the bonding of PMMA. A leak test was performed over 180 h to assess the robustness of the proposed method. Moreover, to promote the applicability of this bonding method, we tested two kinds of microfluidic device applications, including a cell culture-based device and a metal microelectrode-integrated device. The results showed that the cell culture-based application was highly biocompatible with the PMIVIA microdevices fabricated using an acetic acid solvent. Moreover, the low pressure required during the bonding process supported the integration of metal microelectrodes with the PMMA microdevice without any damage to the metal films. This novel bonding method holds great potential in the ecofriendly and rapid fabrication of microfluidic devices using PMMA.
引用
收藏
页码:17396 / 17404
页数:9
相关论文
共 12 条
  • [1] The Design and Fabrication of Poly(dimethylsiloxane) Single Mode Rib Waveguides for Lab-on-a-chip Applications
    Poenar, Daniel Puiu
    Kee, Jack Sheng
    Neuzil, Pavel
    Yobas, Levent
    NEMS/MEMS TECHNOLOGY AND DEVICES, 2009, 74 : 51 - +
  • [2] Rapid Detection of Mobilized Colistin Resistance using a Nucleic Acid Based Lab-on-a-Chip Diagnostic System
    Rodriguez-Manzano, Jesus
    Moser, Nicolas
    Malpartida-Cardenas, Kenny
    Moniri, Ahmad
    Fisarova, Lenka
    Pennisi, Ivana
    Boonyasiri, Adhiratha
    Jauneikaite, Elita
    Abdolrasouli, Alireza
    Otter, Jonathan A.
    Bolt, Frances
    Davies, Frances
    Didelot, Xavier
    Holmes, Alison
    Georgiou, Pantelis
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [3] Rapid Detection of Mobilized Colistin Resistance using a Nucleic Acid Based Lab-on-a-Chip Diagnostic System
    Jesus Rodriguez-Manzano
    Nicolas Moser
    Kenny Malpartida-Cardenas
    Ahmad Moniri
    Lenka Fisarova
    Ivana Pennisi
    Adhiratha Boonyasiri
    Elita Jauneikaite
    Alireza Abdolrasouli
    Jonathan A. Otter
    Frances Bolt
    Frances Davies
    Xavier Didelot
    Alison Holmes
    Pantelis Georgiou
    Scientific Reports, 10
  • [4] Fabrication of stable metallic patterns embedded in poly(dimethylsiloxane) and model applications in non-planar electronic and lab-on-a-chip device patterning
    Lee, KJ
    Tosser, KA
    Nuzzo, RG
    ADVANCED FUNCTIONAL MATERIALS, 2005, 15 (04) : 557 - 566
  • [5] Sucrose-based fabrication of 3D-networked, cylindrical microfluidic channels for rapid prototyping of lab-on-a-chip and vaso-mimetic devices
    Lee, Jiwon
    Paek, Jungwook
    Kim, Jaeyoun
    LAB ON A CHIP, 2012, 12 (15) : 2638 - 2642
  • [6] Non-photolithographic plastic-mold-based fabrication of cylindrical and multi-tiered poly(dimethylsiloxane) microchannels for biomimetic lab-on-a-chip applications
    Jang, Minjeong
    Kwon, Young Jik
    Lee, Nae Yoon
    RSC ADVANCES, 2015, 5 (122) : 100905 - 100911
  • [7] Fabrication of Poly(methyl methacrylate) (PMMA) Microfluidic Chip with Cantor Fractal Structure Using a CO2 Laser System
    Wu, Z.
    Chen, X.
    Zheng, Y.
    Wang, T.
    LASERS IN ENGINEERING, 2019, 43 (1-3) : 121 - 129
  • [8] Fabrication of low-cost MEMS microfluidic devices using metal embossing technique on glass for lab-on-chip applications
    Madhankumar, P.
    Sujatha, L.
    Sundar, R.
    Viswanadam, Gautham
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2023, 33 (08)
  • [9] Fabrication of compact poly(methyl methacrylate-co-butyl methacrylate-co-acrylic acid) microcapsules for electrophoretic displays by using emulsion droplets as templates
    Yu, Fengyang
    Fang, Yi
    Wang, Jingjing
    Xu, Yanling
    Shi, Jun
    COLLOID AND POLYMER SCIENCE, 2016, 294 (08) : 1359 - 1367
  • [10] Fabrication of compact poly(methyl methacrylate-co-butyl methacrylate-co-acrylic acid) microcapsules for electrophoretic displays by using emulsion droplets as templates
    Fengyang Yu
    Yi Fang
    Jingjing Wang
    Yanling Xu
    Jun Shi
    Colloid and Polymer Science, 2016, 294 : 1359 - 1367