Benefit of scatter limitation correction for cold artifacts caused by arm motion in whole-body PET/CT: physical phantom study

被引:0
|
作者
Onishi, H. [1 ]
Furuta, A. [2 ]
Kangai, Y. [1 ]
Yada, N. [1 ]
Saho, T. [1 ]
Amijima, H. [3 ]
机构
[1] Prefectural Univ Hiroshima, Grad Sch Comprehens Sci Res, Program Biol Syst Sci, Mihara, Hiroshima, Japan
[2] Prefectural Univ Hiroshima, Grad Sch Comprehens Sci Res, Program Hlth & Welf Sci, Mihara, Hiroshima, Japan
[3] Hyogo Univ Hlth Sci, Grad Sch Nursing, Kobe, Hyogo, Japan
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
EP744
引用
收藏
页码:S503 / S504
页数:2
相关论文
共 50 条
  • [1] Evaluation of scatter limitation correction: a new method of correcting photopenic artifacts caused by patient motion during whole-body PET/CT imaging
    Miwa, Kenta
    Umeda, Takuro
    Murata, Taisuke
    Wagatsuma, Kei
    Miyaji, Noriaki
    Terauchi, Takashi
    Koizumi, Mitsuru
    Sasaki, Masayuki
    NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (02) : 147 - 154
  • [2] Correction of Patient Arm Motion Artifacts in PET/CT: Scatter-Limit Correction
    Bahn, Y.
    Lee, S.
    Kim, J.
    Oh, S.
    Nam-Koong, H.
    Park, H.
    Kang, C.
    Lim, H.
    Lee, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S632 - S632
  • [3] Effect of patient arm motion in whole-body PET/CT
    Lodge, Martin
    Mhlanga, Joyce
    Wahl, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [4] Effect of Patient Arm Motion in Whole-Body PET/CT
    Lodge, Martin A.
    Mhlanga, Joyce C.
    Cho, Steve Y.
    Wahl, Richard L.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (12) : 1891 - 1897
  • [5] Whole-body motion correction in cardiac PET/CT using Positron Emission Tracking: A phantom validation study
    Manwell, Spencer
    Klein, Ran
    deKemp, Robert
    Xu, Tong
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [6] Elastic Motion Correction For Continuous Bed Motion Whole-body PET/CT
    Hong, Inki
    Jones, Judson
    Hamill, James
    Michel, Christian
    Casey, Michael
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [7] Impact of elastic motion correction on quantitation and image quality of whole-body PET/CT
    Meier, Joseph
    Hamill, James
    Jones, Judson
    Hong, Inki
    Mawlawi, Osama
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [8] Simulating respiratory motion in whole-body PET imaging with the MCAT phantom
    Isoardi, RA
    Comtat, C
    Frouin, V
    Delzescaux, T
    Trébossen, R
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1113 - 1115
  • [9] Improvement of motion artifacts using dynamic whole-body 18F-FDG PET/CT imaging
    Tomohito Kaji
    Kouji Osanai
    Atsushi Takahashi
    Atsushi Kinoshita
    Daiki Satoh
    Tomoaki Nakata
    Nagara Tamaki
    Japanese Journal of Radiology, 2024, 42 : 374 - 381
  • [10] Improvement of motion artifacts using dynamic whole-body 18F-FDG PET/CT imaging
    Kaji, Tomohito
    Osanai, Kouji
    Takahashi, Atsushi
    Kinoshita, Atsushi
    Satoh, Daiki
    Nakata, Tomoaki
    Tamaki, Nagara
    JAPANESE JOURNAL OF RADIOLOGY, 2023, 42 (4) : 374 - 381