Research on Measurement Accuracy of Electronic Current Transformer under Vibration

被引:0
|
作者
Cheng, Ying-Ying [1 ]
Du, Jie [1 ]
Guo, Li-Huang [2 ]
Xiao, Ji [1 ]
Zhang, Jia-Ming [1 ]
Yang, Hua-Xiao [1 ]
机构
[1] State Grid Chongqing Elect Power Co, Elect Power Res Inst, Chongqing 401123, Peoples R China
[2] Guodian Nanjing Automat Co Ltd, Nanjing 211100, Jiangsu, Peoples R China
关键词
Electronic transformer; Vibration test; Measurement accuracy; Circuit breaker;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The electronic current transformer (ECT) (especially optical current transformers) contains electronic and optical devices, so it is sensitive to vibration, and the abnormal output of the ECT affected by vibration interference may cause measurement deviations. Base on the National Standard for Electronic Transformer, this paper designs the test system and method of the ECT under the vibration disturbance during the operation of the circuit breaker. The randomly selected optical current transformers were tested, it showed that, under the mechanical coupling vibration of the circuit breaker, the maximum percent of root-mean-square value of each cycle of the secondary output signal is 0.48% of the rated output and the peak value is 0.72%, which can meet the requirement of measurement accuracy. The design of the test system and method is beneficial to improve the inspection level and promote the application of ECTs.
引用
收藏
页码:33 / 38
页数:6
相关论文
共 50 条
  • [41] Transformer eddy current dampers for the vibration control
    Tonoli, Andrea
    Amati, Nicola
    Silvagni, Mario
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 2008, 130 (03):
  • [42] MEASUREMENT OF MAGNETOSTRICTION AND VIBRATION WITH REGARD TO TRANSFORMER NOISE
    MOSES, AJ
    IEEE TRANSACTIONS ON MAGNETICS, 1974, MA10 (02) : 154 - 156
  • [43] Vibration Performance of a Power Electronic Transformer Under Different Phase-shift Modulation Methods
    Peng, Xiaokang
    Liu, Zicheng
    Jiang, Dong
    2021 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2021, : 4454 - 4459
  • [44] Vibration Performance of a Power Electronic Transformer Under Different Phase-Shift Modulation Methods
    Jiang, Dong
    Peng, Xiaokang
    Liu, Zicheng
    Wang, Pengye
    Yan, She
    Qu, Ronghai
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (06) : 7529 - 7538
  • [45] Improvement of Current Transformer Accuracy by Digital CompensationTechnique
    Ballal, Makarand S.
    Wath, Manish G.
    Suryawanshi, H. M.
    Venkatesh, B.
    2018 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2018,
  • [46] ON THE ACCURACY OF MEASUREMENT BY SEISMIC VIBRATION TRANSDUCERS
    PAVIC, G
    STROJARSTVO, 1986, 28 (01): : 35 - 43
  • [47] Research on Dynamic Vibration of Transformer Cores under Wireless Power Transfer System Load
    Zhu, L.
    Yang, Q.
    Zhang, X.
    Yan, R.
    2015 IEEE MAGNETICS CONFERENCE (INTERMAG), 2015,
  • [48] Experimental Research on Power Transformer Vibration Distribution under Different Winding Defect Conditions
    Hu, Yiwei
    Zheng, Jing
    Huang, Hai
    ELECTRONICS, 2019, 8 (08)
  • [49] Research on the performance of a fiber optical current transformer for high voltage filtering capacitor unbalanced current measurement
    Zhao, Jun
    Xu, Shengguo
    Wu, Baofeng
    Sun, Xiaohan
    JOURNAL OF OPTICAL TECHNOLOGY, 2022, 89 (06) : 353 - 358
  • [50] Impact of Coreless Current Transformer Position on Current Measurement
    Xiang, Yukai
    Lin, Xu
    Chen, Xianan
    Chen, Kun-Long
    2018 IEEE 9TH INTERNATIONAL WORKSHOP ON APPLIED MEASUREMENTS FOR POWER SYSTEMS (AMPS), 2018, : 178 - 182