PD Positioning Method and Experimental Study Based on Circular-shaped Ultrasonic Array Sensors

被引:0
|
作者
Li Yanqing [1 ]
Wang Fei [1 ]
Wang Chuan [1 ]
Hu Weitao [1 ]
Xie Qing [1 ]
Tao Junhan [1 ]
机构
[1] North China Elect Power Univ Baoding, Baoding City, Hebei Province, Peoples R China
关键词
partial discharge; circular-shaped ultrasound array sensor; positioning algorithm; experimental system;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
PD ultrasound array positioning method is one of the latest achievements in the field of array sensor technology and array signal processing technology. This method can achieve spatial orientation and on-line monitoring of partial discharge source effectively. Ultrasonic array sensor was developed rapidly in the past forty years, its application involves many areas of military and national such as radar, exploration, sonar, communications, seismology, radio astronomy, biomedical engineering, etc. Previous studies showed that the positioning performance of circular-shaped array sensor is superior to the square, linear array sensor and other forms. Therefore, we undertook in-depth study in allusion to circular-shaped ultrasonic array sensor. Contents of this paper are summed up in the following three aspects. Firstly, this paper developed a circular-shaped ultrasonic array sensor. We carried out a detailed and comprehensive investigation on structures, materials and size parameters of array sensor elements and assemblies, and we combined with the specific characteristics of PD ultrasound signals, then we determine the structure of array sensor elements and its main parameters: the dimensions of probe and tail are Phi 7.8x13mm Phi 5.2x13mm, the frequency range is 70kHz-280kHz, etc. The assembly is made of aviation aluminum materials, its sizes are as follows: length is 50mm, width is 40mm, the cylindrical bores in circular-shaped ultrasonic array sensor assemblies are arranged in a circular ring shape, the diameter of the cylindrical bore is 5.2mm, and the depth of the cylindrical bore is 5mm. We get circular-shaped ultrasonic array sensor by assembling ultrasonic array sensor elements and array sensor assembly. Secondly, since the actual PD ultrasonic signals from electrical equipments are wideband signals, we adopt rotational signal subspace (RSS) algorithm to focus processing, which can reserve the information maximally to realize the direction information accumulation of wideband signals. Use multiple signal classification (MUSIC) to realize DOA estimation of PD broadband ultrasonic array signals, its principle is to use the orthogonal characteristics of signal subspace and noise subspace. Then we adopt a kind of three-platform algorithm to locate the PD source. Lastly, we built a set up of PD ultrasonic array positioning system, which can realize reception, acquisition and processing of PD ultrasonic signals. This PD positioning system consists of partial discharge simulation system, signal reception and transmission system, multi-channel data synchronous acquisition and processing system, and computers. With this set of PD ultrasonic array positioning system we carried out experimental studies, we collected experimental data by changing the positions of partial discharge source and the circular-shaped ultrasonic array sensors, the results show that the positioning error is less than 8cm. The experimental studies showed that the PD positioning experimental system based on circular-shaped ultrasonic array sensor and the positioning algorithm are effective to locate PD source and can meet project needs, and lay the foundation for the practical application of engineering.
引用
收藏
页码:1565 / 1570
页数:6
相关论文
共 50 条
  • [41] Networked Ultrasonic Sensors for Target Tracking: An Experimental Study
    Li, Hongbin
    Miao, Di
    Chen, Jiming
    Sun, Youxian
    Shen, Xuemin
    GLOBECOM 2009 - 2009 IEEE GLOBAL TELECOMMUNICATIONS CONFERENCE, VOLS 1-8, 2009, : 3581 - +
  • [42] Method for measuring the membrane penetration of triaxial specimens based on an external circular array of laser displacement sensors
    Zhang, Jiachen
    Ji, Xiaomeng
    Kong, Xianjing
    Liu, Jingmao
    Zou, Degao
    Zhou, Chenguang
    Fu, Yongkui
    MEASUREMENT, 2023, 217
  • [43] Ultrasonic phased array inspection method for the corner of L-shaped components
    Xu, Na
    Zhou, Zhenggan
    Liu, Weiping
    Zhou, Hui
    Yu, Guang
    Hangkong Xuebao/Acta Aeronautica et Astronautica Sinica, 2013, 34 (02): : 419 - 425
  • [44] Concentric circular-shaped electronically steerable parasitic array radiator antennas for full-azimuth directions of arrival estimation with reduced computational load
    Akkar, S.
    Harabi, F.
    Gharsallah, A.
    IET MICROWAVES ANTENNAS & PROPAGATION, 2012, 6 (11) : 1236 - 1243
  • [45] Comparison of the acoustic performance and positioning accuracy of three kinds of planar partial discharge ultrasonic array sensors
    Xie, Qing
    Li, Tong
    Tao, Junhan
    Liu, Xuying
    Liu, Dan
    Xu, Yuqin
    IET RADAR SONAR AND NAVIGATION, 2016, 10 (01): : 166 - 173
  • [46] Effects of core geometry, silica nanoparticles, and polyurethane foam on the mechanical properties of a novel circular-shaped core sandwich panels under compression test: Experimental study
    Shaki, Mohammad Hassan
    Rostamiyan, Yasser
    Seyedi, Seyed Masuod
    JOURNAL OF COMPOSITE MATERIALS, 2024, 58 (17) : 1919 - 1933
  • [47] Study on Gas Leakage Localization Method Based on Ultrasonic Sensor Area Array
    Xu Mengjie
    Wang Tao
    2017 IEEE INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2017, : 136 - 141
  • [48] Simulation and performance study of circular ultrasonic array for tubes' internal inspection
    Xi, Ze
    Luo, Xiaowei
    Peng, Yahui
    Wang, Xiangang
    ULTRASONICS, 2021, 116
  • [49] Proof of principle study of ultrasonic particle manipulation by a circular array device
    Grinenko, Alon
    Wilcox, Paul D.
    Courtney, Charles R. P.
    Drinkwater, Bruce W.
    PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2012, 468 (2147): : 3571 - 3586
  • [50] Study of Current Measurement Method Based on Circular Magnetic Field Sensing Array
    Li, Zhenhua
    Zhang, Siqiu
    Wu, Zhengtian
    Abu-Siada, Ahmed
    Tao, Yuan
    SENSORS, 2018, 18 (05)