Out-of-Step Protection Using Equal Area Criterion in Time Domain

被引:0
|
作者
Sauhats, Antans [1 ]
Utans, Andrejs [1 ]
Antonovs, Dmitrijs [1 ]
Biela-Dalidovicha, Edite [1 ]
机构
[1] Riga Tech Univ, Inst Power Engn, Riga, Latvia
关键词
angular instability; out-of-step protection; equal area criterion in time domain; wide-area measurements; SLOW COHERENCY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes the out-of-step (OOS) protection system, which operation principle is based on combination of two approaches: equal area criterion, implemented in time domain, is used for generators first swing stability assessment and generation sources electromotive forces (emf) vectors angle control is used for multi swing instability detection. The paper focuses on possibilities of practical implementation of the above mentioned approaches within real time operating OOS protection system. Protection system structure and principles of operation addressed in the paper.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Out-of-Step detection based on an improved line potential energy criterion
    Li, Xiao
    Liu, Chongru
    Ma, Jin
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 199
  • [42] Characteristic Analysis and Calculation of Frequencies of Voltages in Out-of-Step Oscillation Power System and a Frequency-Based Out-of-Step Protection
    Zhang, Shuai
    Zhang, Yanxia
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2019, 34 (01) : 205 - 214
  • [43] Improvement of the Fast Out-of-step Separation Criterion in Electric Power System
    Yang, Yuang
    Yang, Mingyu
    Xiang, Li
    Ding, Maosheng
    Song, Yunting
    MECHATRONICS, ROBOTICS AND AUTOMATION, PTS 1-3, 2013, 373-375 : 1357 - +
  • [44] Out-of-Step Splitting Framework Based on Adaptive Separation Detecting Criterion
    Li, Li
    Liu, Yutian
    T& D ASIA: 2009 TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: ASIA AND PACIFIC, 2009, : 739 - 743
  • [45] Out-of-Step and Single Phasing Protection of Synchronous Chipper Motors
    Das, J. C.
    Steinmetz, Jon D.
    McPhee, Aaron A.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2016, 52 (02) : 1931 - 1937
  • [46] Improvement of out-of-step separation criterion based on apparent impedance angle
    Qu Y.
    Shi B.
    Liu Z.
    Zhang Y.
    Chi Z.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (05): : 181 - 187
  • [47] Automatic Out-of-step Protection of Synchronous Motor Supplied by Converter
    Wang, Aiyuan
    Ling, Zhihao
    2009 THIRD INTERNATIONAL SYMPOSIUM ON INTELLIGENT INFORMATION TECHNOLOGY APPLICATION, VOL 2, PROCEEDINGS, 2009, : 590 - +
  • [48] Study on out-of-step oscillation criterion based on bus voltage frequency
    School of Electrical Engineering, Wuhan University, Wuhan
    Hubei Province
    430072, China
    不详
    Guangdong Province
    510080, China
    不详
    Jiangsu Province
    223001, China
    Zhongguo Dianji Gongcheng Xuebao, 12 (2998-3007):
  • [49] Out-of-step oscillation splitting criterion based on bus voltage frequency
    Tang, Fei
    Yang, Jian
    Liao, Qingfen
    Wang, Yifei
    Jia, Jun
    Journal of Modern Power Systems and Clean Energy, 2015, 3 (03) : 341 - 352
  • [50] Setting and Testing of the Out-of-Step Protection at Mongolian Transmission System
    Gonzalez-Longatt, Francisco
    Adiyabazar, Choidorj
    Martinez, Ernesto Vazquez
    ENERGIES, 2021, 14 (23)