Optimal successive start-up strategy of two hydraulic coupling pumped storage units based on multi-objective control

被引:30
|
作者
Hou, Jinjiao [1 ]
Li, Chaoshun [1 ]
Guo, Wencheng [1 ]
Fu, Wenlong [2 ,3 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Hydropower & Informat Engn, Wuhan 430074, Hubei, Peoples R China
[2] China Three Gorges Univ, Coll Elect Engn & New Energy, Yichang 443002, Peoples R China
[3] China Three Gorges Univ, Hubei Prov Key Lab Operat & Control Cascaded Hydr, Yichang 443002, Peoples R China
基金
中国国家自然科学基金;
关键词
Pumped storage power station; Hydraulic coupling units; Successive start-up; Multi-objective optimization; TURBINE GOVERNING SYSTEM; FREQUENCY CONTROL; POWER-SYSTEM; PREDICTIVE CONTROL; WIND POWER; SURGE TANK; STABILITY; PV; PERFORMANCE; STATION;
D O I
10.1016/j.ijepes.2019.04.033
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper aims to study the optimal successive start-up strategy of two hydraulic coupling pumped storage units (PSUs) based on multi-objective control. Firstly, a successive start-up model of a pumped storage power station (PSPS) with two PSUs is established. Secondly, the analysis of the impact of successive time interval Delta T is carried out. Thirdly, a novel optimization scheme multi-objective with two PSUs owning different parameters (MODP) is proposed for start-up optimization. For comparison, three optimization schemes named single objective with two PSUs sharing the same parameters (SOSP), single objective with two PSUs owning different parameters (SODP) and multi-objective with two PSUs sharing the same parameters (MOSP) are also tested. Finally, according to the four optimization schemes, i.e. SOSP, SODP, MOSP and MODP, the optimization model is established and performed separately in MATLAB 9.1 based on a real case. The results indicate that the change of AT has a great effect on the transient process of 1# PSU, but less effect on the transient process of 2# PSU. Delta T should be chosen as a decision variable in the successive start-up optimization. For the successive start-up of a PSPS with two PSUs, the multi-objective scheme is superior to the single-objective scheme. The scheme of different parameters is superior to the scheme of sharing parameters. Among four schemes, MODP scheme is the best. The MODP scheme can obtain the Pareto Set that provides more choices for decision makers, which is flexible in engineering applications. MODP is a general method for successive start-up strategy optimization.
引用
收藏
页码:398 / 410
页数:13
相关论文
共 50 条
  • [21] Adaptive condition predictive-fuzzy PID optimal control of start-up process for pumped storage unit at low head area
    Xu, Yanhe
    Zheng, Yang
    Du, Yi
    Yang, Wen
    Peng, Xuyi
    Li, Chaoshun
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2018, 177 : 592 - 604
  • [22] Studies on closed-loop start-up control strategy and simulation for hydroelectric generating units
    Kang, Ling
    Ye, Luqing
    [J]. Shuili Fadian Xuebao/Journal of Hydroelectric Engineering, 2000, (01): : 55 - 61
  • [23] Multi-objective optimal control strategy design for substations in HAVC system
    Xie, Bang-Peng
    Zhang, Xue-Min
    Mei, Sheng-Wei
    [J]. Kongzhi Lilun Yu Yingyong/Control Theory and Applications, 2009, 26 (11): : 1251 - 1255
  • [24] Optimal control of excitation system of pumped storage unit based on hydraulic-mechanical-electrical coupling model
    Xu, Yanhe
    Zhao, Kunjie
    Lyu, Cong
    Zhou, Jianzhong
    [J]. Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2021, 49 (12): : 28 - 33
  • [25] Optimal Control Strategy of AGC With Participation of Energy Storage System Based on Multi-objective Mesh Adaptive Direct Search Algorithm
    Lu, Xiaojun
    Yi, Jianwei
    Li, Yan
    [J]. Dianwang Jishu/Power System Technology, 2019, 43 (06): : 2116 - 2124
  • [26] Multi-objective Cooperative Combustion Optimization Control Strategy for Thermal Power Units Based on IGPC Decoupling Control
    Feng, Xugang
    Bao, Lichang
    Zhang, Jiayan
    Wang, Sheng
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (09): : 3223 - 3231
  • [27] Model-based design of a control strategy for optimal start-up of a high-strength nitrification system
    Jubany, I.
    Baeza, J. A.
    Carrera, J.
    Lafuente, J.
    [J]. ENVIRONMENTAL TECHNOLOGY, 2007, 28 (02) : 185 - 194
  • [28] A multi-objective operation strategy optimization for ice storage systems based on decentralized control structure
    Ren, Yanhuan
    Yu, Junqi
    Zhao, Anjun
    Jing, Wenqiang
    Ran, Tong
    Yang, Xiong
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2021, 42 (01): : 62 - 81
  • [29] A Stable Start-up Control Strategy for VSC-based DC Microgrid
    Wan, Qingzhu
    Guo, Jia
    Li, Juntao
    [J]. 2018 21ST INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2018, : 2076 - 2079
  • [30] Design of bean pumping units based on Multi-objective Optimal Evolutionary Algorithm
    Li, Keqing
    Ouyang, Shan
    Yu, Fahong
    [J]. ICNC 2007: Third International Conference on Natural Computation, Vol 5, Proceedings, 2007, : 605 - 608