Optimal successive start-up strategy of two hydraulic coupling pumped storage units based on multi-objective control

被引:30
|
作者
Hou, Jinjiao [1 ]
Li, Chaoshun [1 ]
Guo, Wencheng [1 ]
Fu, Wenlong [2 ,3 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Hydropower & Informat Engn, Wuhan 430074, Hubei, Peoples R China
[2] China Three Gorges Univ, Coll Elect Engn & New Energy, Yichang 443002, Peoples R China
[3] China Three Gorges Univ, Hubei Prov Key Lab Operat & Control Cascaded Hydr, Yichang 443002, Peoples R China
基金
中国国家自然科学基金;
关键词
Pumped storage power station; Hydraulic coupling units; Successive start-up; Multi-objective optimization; TURBINE GOVERNING SYSTEM; FREQUENCY CONTROL; POWER-SYSTEM; PREDICTIVE CONTROL; WIND POWER; SURGE TANK; STABILITY; PV; PERFORMANCE; STATION;
D O I
10.1016/j.ijepes.2019.04.033
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper aims to study the optimal successive start-up strategy of two hydraulic coupling pumped storage units (PSUs) based on multi-objective control. Firstly, a successive start-up model of a pumped storage power station (PSPS) with two PSUs is established. Secondly, the analysis of the impact of successive time interval Delta T is carried out. Thirdly, a novel optimization scheme multi-objective with two PSUs owning different parameters (MODP) is proposed for start-up optimization. For comparison, three optimization schemes named single objective with two PSUs sharing the same parameters (SOSP), single objective with two PSUs owning different parameters (SODP) and multi-objective with two PSUs sharing the same parameters (MOSP) are also tested. Finally, according to the four optimization schemes, i.e. SOSP, SODP, MOSP and MODP, the optimization model is established and performed separately in MATLAB 9.1 based on a real case. The results indicate that the change of AT has a great effect on the transient process of 1# PSU, but less effect on the transient process of 2# PSU. Delta T should be chosen as a decision variable in the successive start-up optimization. For the successive start-up of a PSPS with two PSUs, the multi-objective scheme is superior to the single-objective scheme. The scheme of different parameters is superior to the scheme of sharing parameters. Among four schemes, MODP scheme is the best. The MODP scheme can obtain the Pareto Set that provides more choices for decision makers, which is flexible in engineering applications. MODP is a general method for successive start-up strategy optimization.
引用
收藏
页码:398 / 410
页数:13
相关论文
共 50 条
  • [1] Optimal successive start-up strategy of two hydraulic coupling pumped storage units based on multi-objective control (vol 111, pg 398, 2019)
    Hou, Jinjiao
    Li, Chaoshun
    Guo, Wencheng
    Fu, Wenlong
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 123
  • [2] Multi-Objective Optimization of Start-up Strategy for Pumped Storage Units
    Hou, Jinjiao
    Li, Chaoshun
    Tian, Ziqin
    Xu, Yanhe
    Lai, Xinjie
    Zhang, Nan
    Zheng, Taoping
    Wu, Wei
    [J]. ENERGIES, 2018, 11 (05)
  • [3] Optimal Multi-objective Units Start-up Strategy Based on Greedy Algorithm
    Zhang, Bowen
    Shi, Libao
    Ni, Yixin
    Yao, Liangzhong
    Bazargan, Masoud
    [J]. 2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [4] A Generator Start-Up Optimization Strategy Based on the Preference Multi-objective Optimization
    Zhang, De
    Xie, Yuzheng
    Zou, Wenqiu
    Li, Gengfeng
    Yang, Qiming
    Xu, Mingqian
    Li, Minghao
    [J]. 2022 INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING AND POWER ENGINEERING, MEPE, 2022, : 79 - 84
  • [5] Dynamic Characteristics and Successive Start-Up Control Strategy Optimization of Pumped Storage Units under Low-Head Extreme Conditions
    Li, Yonggang
    Hou, Jinjiao
    Gu, Juan
    Li, Chaoshun
    Xu, Yanhe
    [J]. ENERGIES, 2022, 15 (15)
  • [6] A multi-objective optimization strategy for the optimal control scheme of pumped hydropower systems under successive load rejections
    Lai, Xinjie
    Li, Chaoshun
    Zhou, Jianzhong
    Zhang, Yongchuan
    Li, Yonggang
    [J]. APPLIED ENERGY, 2020, 261
  • [7] Analysis of a Static Start-up Control Strategy for Pumped Storage Power Plant Unit
    Wang, Deshun
    Yang, Bo
    Li, Guanjun
    Tao, Yibin
    Sang, Bingyu
    [J]. INTERNATIONAL CONFERENCE ON APPLIED PHYSICS AND INDUSTRIAL ENGINEERING 2012, PT A, 2012, 24 : 155 - 162
  • [8] Model-free adaptive optimal control for fast and safe start-up of pumped units
    Liu, Dong
    Zhang, Jingjing
    Lu, Xueding
    Li, Chaoshun
    Malik, O. P.
    [J]. JOURNAL OF ENERGY STORAGE, 2024, 87
  • [9] Analysis of hydraulic characteristics during low head start-up transition of pumped storage units based on entropy production theory
    Chen, Huixiang
    Liu, Hanzhong
    Kan, Kan
    Xu, Hui
    Feng, Jiangang
    Aboule, Leonce Mossandre
    [J]. JOURNAL OF ENERGY STORAGE, 2024, 102
  • [10] An Integrated Start-Up Method for Pumped Storage Units Based on a Novel Artificial Sheep Algorithm
    Wang, Zanbin
    Li, Chaoshun
    Lai, Xinjie
    Zhang, Nan
    Xu, Yanhe
    Hou, Jinjiao
    [J]. ENERGIES, 2018, 11 (01)