Electromagnetic compatibility analysis of a control strategy for a hybrid active filter

被引:10
|
作者
Litran, Salvador P. [1 ]
Salmeron, Patricio [1 ]
机构
[1] Huelva Univ, Dept Elect Engn, Huelva, Spain
关键词
Harmonics; Electric power quality; Active filter; Hybrid filter; EMC test; POWER FILTER; COMPENSATION; SYSTEMS; HARMONICS; QUALITY; DESIGN;
D O I
10.1016/j.epsr.2016.11.014
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper a control strategy for a hybrid filter has been proposed. The hybrid filter consists of an active power filter connected in series with the source and a passive filter connected in parallel with the load. The proposed strategy is based on minimizing the effective value of the voltage at the point of common coupling to ensure the transfer of the power demanded by the load. By applying the Lagrange multipliers, the value of the equivalent resistance of the set load-compensator was determined in order to achieve unity power factor. An experimental prototype was designed to verify its behavior. The compensation equipment operation was analyzed from the point of view of the system stability and from their behavior regarding disturbances of the grid voltage. For this, the hybrid filter was subjected to six electromagnetic compatibility test as it is defined in IEC 61000 standard. In all tests, the equipment maintained its functionality before, during and after the perturbation in the supply voltage. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 50 条
  • [21] A novel passive control strategy for transformerless shunt hybrid active power filter
    Meng, Chao
    Li, Po
    Hong, Yongqiang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2013, 37 (07): : 108 - 112
  • [22] Intelligent control strategy of high-capacity hybrid active power filter
    Wu, Jingbing
    Luo, An
    Xu, Xianyong
    Zhao, Wei
    Yang, Xiaofeng
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2010, 30 (04): : 36 - 41
  • [23] A control strategy for shunt active filter
    Aredes, M
    Monteiro, LFC
    10TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, VOLS I AND II, PROCEEDINGS, 2002, : 472 - 477
  • [24] Analysis and control of a reduced switch hybrid active power filter
    Luo, Zhaoxu
    Su, Mei
    Sun, Yao
    Zhang, Wei
    Lin, Zhili
    IET POWER ELECTRONICS, 2016, 9 (07) : 1416 - 1425
  • [25] Analysis of modeling and control characteristic of hybrid active power filter
    Hunan University, Changsha 410082, China
    Dianli Xitong Zidonghue, 2007, 1 (65-69):
  • [26] Electromagnetic Compatibility and Radiation Analysis in Control Room
    Kucera, Matej
    Gutten, Miroslav
    Simko, Milan
    Sebok, Milan
    Korenciak, Daniel
    Jarina, Roman
    Pitonak, Martin
    MEASUREMENT SCIENCE REVIEW, 2019, 19 (03): : 126 - 131
  • [27] A novel parallel inductor type hybrid active power filter and its control strategy
    Zheng, Jian-Yong
    Zhang, Yu
    Ding, Zu-Jun
    Dianwang Jishu/Power System Technology, 2010, 34 (01): : 90 - 97
  • [28] Dual-loop control strategy of hybrid active power filter with injection circuit
    Hunan University, Changsha 410082, China
    Diangong Jishu Xuebao, 2009, 9 (127-133+139):
  • [29] PLL-Less Control Strategy Applied to Hybrid Active Series Power Filter
    Gonzatti, R. B.
    Ferreira, S. C.
    da Silva, Carlos H.
    Borges da Silva, L. E.
    Lambert-Torres, G.
    Fernandez Silva, L. G.
    2012 10TH IEEE/IAS INTERNATIONAL CONFERENCE ON INDUSTRY APPLICATIONS (INDUSCON), 2012,
  • [30] Study of Fast Repetitive Control Strategy Based on Transformerless Hybrid Active Power Filter
    Song J.
    Wang X.
    Lin L.
    Gao Y.
    Lü S.
    Sun T.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (07): : 2037 - 2045