Validation protocol for whole-body dosimetry in an agricultural exposure study

被引:5
|
作者
Lee, Jiho [1 ]
Kim, Eunhye [1 ]
Shin, Yongho [1 ]
Lee, Jonghwa [1 ]
Lee, Junghak [1 ]
Maasfeld, Wolfgang [2 ]
Kim, Jeong-Han [1 ]
机构
[1] Seoul Natl Univ, Res Inst Agr & Life Sci, Dept Agr Biotechnol, Seoul 08826, South Korea
[2] Bayer CropSci, D-40789 Monheim, Germany
关键词
Exposure; IOM sampler; Kresoxim-methyl; Method validation; Pesticide; Whole-body dosimetry; POTENTIAL DERMAL EXPOSURE; RISK-ASSESSMENT; APPLE ORCHARD; MANDARIN FIELDS; MANUAL SPRAYERS; OPERATORS; APPLICATORS; GREENHOUSES; RESIDUE; WORKERS;
D O I
10.1007/s13765-017-0330-8
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Agricultural workers exposed to pesticides can experience adverse health impacts depending on toxicity and exposure amount. Whole-body dosimetry (WBD) is the most reliable, practical, and realistic method for measuring exposure. Since validation of analytical and experimental methodologies is critical for quantitative determination of exposure, we conducted a validation procedure to design an essential protocol for WBD exposure studies. Using the fungicide kresoxim-methyl, matrix-matched standards were prepared with various matrices including outer cloth, inner cloth, washing solution for gloves and hands, gauze, and glass fiber filter (IOM sampler) to determine the instrumental limit of quantitation for high-performance liquid chromatography (HPLC) (2 ng) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) (10 pg). Method limits of quantitation (MLOQ) were also set for HPLC (0.1 mg/L) and LC-MS/MS (0.005 mg/L). We observed good analysis repeatability (coefficient of variation < 6%), and the linearity of the calibration curves was reasonable (r(2) > 0.998) in the range of 0.001-10 mg/L in various matrices. Recovery tests were carried out at three levels of concentration (MLOQ, 10 MLOQ, and 100 MLOQ) and resulted in good recoveries (72.7-105.6%). We did not observe breakthrough of the compound in tests of holding capacity for glass fiber pesticide filters. The procedures established in the present study are applicable as an essential, comprehensive protocol for exposure assessment studies using WBD.
引用
收藏
页码:125 / 130
页数:6
相关论文
共 50 条
  • [21] DOSIMETRY OF A WHOLE-BODY IRRADIATION FOR BONE-MARROW TRANSPLANTATION
    CHRIST, G
    SAILER, U
    SEEGER, W
    [J]. STRAHLENTHERAPIE, 1982, 158 (09) : 541 - 545
  • [22] Assessment of potential dermal and inhalation exposure of workers to the insecticide imidacloprid using whole-body dosimetry in China
    Cao, Lidong
    Chen, Bo
    Zheng, Li
    Wang, Dongwei
    Liu, Feng
    Huang, Qiliang
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCES, 2015, 27 : 139 - 146
  • [23] WHOLE-BODY VIBRATION EXPOSURE AND THE HUMAN SPINE
    WASSERMAN, DE
    [J]. SOUND AND VIBRATION, 1995, 29 (04): : 5 - 5
  • [24] Assessment of potential dermal and inhalation exposure of workers to the insecticide imidacloprid using whole-body dosimetry in China
    Lidong Cao
    Bo Chen
    Li Zheng
    Dongwei Wang
    Feng Liu
    Qiliang Huang
    [J]. Journal of Environmental Sciences, 2015, 27 (01) : 139 - 146
  • [25] Exposure of agricultural pilots to occupational whole-body vibration: The effects of runway maintenance and the stages of flight
    Zanatta, Mateus
    Amaral, Fernando Gonsalves
    Giacomello, Cintia Paese
    [J]. INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2021, 81
  • [26] Experimental analysis of occupational whole-body vibration exposure of agricultural tractor with large square baler
    Langer, Thomas H.
    Ebbesen, Morten K.
    Kordestani, Ario
    [J]. INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2015, 47 : 79 - 83
  • [27] Feasibility and acceptability of a Whole-Body hyperthermia (WBH) protocol
    Mason, Ashley E.
    Fisher, Sarah M.
    Chowdhary, Anoushka
    Guvva, Ekaterina
    Veasna, Danou
    Floyd, Erin
    Fender, Sean B.
    Raison, Charles
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (01) : 1529 - 1535
  • [28] On the Optimal Whole-Body Vibration Protocol for Muscle Strength
    Al Masud, Abdullah
    Shen, Chwan-Li
    Chyu, Ming-Chien
    [J]. BIOMECHANICS, 2022, 2 (04): : 547 - 561
  • [29] Comparison of a new whole-body continuous-table-movement protocol versus a standard whole-body MR protocol for the assessment of multiple myeloma
    S. Weckbach
    H. J. Michaely
    A. Stemmer
    S. O. Schoenberg
    D. J. Dinter
    [J]. European Radiology, 2010, 20 : 2907 - 2916
  • [30] Development and dosimetry analysis of a 2-GHz whole-body exposure setup for unrestrained pregnant and newborn rats
    Wang, Jianqing
    Fujiwara, Osamu
    Kawai, Hiroki
    Wake, Kanako
    Watanabe, Soichi
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2008, 56 (08) : 2008 - 2013