Objective: To evaluate the Ahmed Glaucoma Valve implant, an aqueous shunting device with a unidirectional valve mechanism, in patients younger than 18 years. Design: Prospective case series. Setting: Tertiary care hospital. Patients: Twenty-one consecutive patients younger than 18 years. The median age of patients was 4.8 years (range, 0.23-17.9 years). Intervention: Placement of an Ahmed Glaucoma Valve implant between April 1992 and April 1994. Main Outcome Measure: Time after surgery without failure. Success was defined as an average intraocular pressure less than 22 mm Hg for the last 2 follow-ups in eyes with preoperative intraocular pressure greater than 22 mm Hg, or an intraocular pressure that was lowered by at least 20% from preoperative values in eyes with preoperative intraocular pressure less than 22 mm Hg, and no additional glaucoma surgeries or visually devastating complications. Results: Cumulative probabilities of success at 12 and 24 months were 77.9%+/-8.8% and 60.6%+/-13.7%, respectively. One eye had a flat anterior chamber and suprachoroidal hemorrhage on the first postoperative day. No other eyes had flat or shallow anterior chambers that required reformation. In 3 eyes the implant extruded from underneath the conjunctiva and was removed. In 2 other eyes the average intraocular pressure for the last 2 follow-ups was greater than 22 mm Hg. In 1 eye with an intraocular pressure less than 22 mm Hg preoperatively, the intraocular pressure was not reduced by at least 20%, although the number of antiglaucoma medications was reduced. Conclusion: The 12- and 24-month success rates of the Ahmed Glaucoma Valve implant are similar to those of other implants when used in a pediatric population.
引用
收藏
页码:186 / 191
页数:6
相关论文
共 50 条
  • [1] INITIAL CLINICAL-EXPERIENCE WITH THE AHMED GLAUCOMA VALVE IMPLANT
    COLEMAN, AL
    HILL, R
    WILSON, MR
    CHOPLIN, N
    KOTASNEUMANN, R
    TAM, M
    BACHARACH, J
    PANEK, WC
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 120 (01) : 23 - 31
  • [2] Initial clinical experience with the Ahmed glaucoma valve implant in the management of neovascular glaucoma
    Patel, S
    Ge, N
    Varma, R
    Chen, P
    Heuer, D
    Lee, P
    Dacey, M
    Philips, A
    Minckler, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1173 - 1173
  • [3] Initial clinical experience with the Ahmed glaucoma valve implant in the management of complicated glaucoma.
    Ge, N
    Patel, S
    Heuer, D
    Minckler, D
    Varma, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1178 - 1178
  • [4] INITIAL CLINICAL EXPERIENCE WITH AHMED VALVE IMPLANTATION IN REFRACTORY PEDIATRIC GLAUCOMA
    Novak-Laus, Katia
    Herman, Jelena Skunca
    Prskalo, Marija Simic
    Jurisic, Darija
    Mondic, Zdravko
    ACTA CLINICA CROATICA, 2016, 55 (04) : 555 - 559
  • [5] INITIAL CLINICAL-EXPERIENCE WITH THE AHMED GLAUCOMA VALVE IMPLANT-CORRECTION
    COLEMAN, AL
    WILSON, MR
    TAM, M
    HILL, R
    CHOPLIN, N
    KOTASNEUMANN, R
    BACHARACH, J
    PANEK, WC
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 120 (05) : 684 - 684
  • [6] Intermediate-term clinical experience with the Ahmed Glaucoma Valve implant
    Huang, MC
    Netland, PA
    Coleman, AL
    Siegner, SW
    Moster, MR
    Hill, RA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 127 (01) : 27 - 33
  • [7] Clinical evaluation and risk factors of time to failure of ahmed glaucoma valve implant in pediatric patients
    Djodeyre, MR
    Calvo, JP
    Gomez, JA
    OPHTHALMOLOGY, 2001, 108 (03) : 614 - 620
  • [8] Ahmed glaucoma valve implant: Experience in East Africa
    Kiage, D. O.
    Gradin, D.
    Gichuhi, S.
    Damji, K. F.
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2009, 16 (03) : 151 - 155
  • [9] One year clinical experience with the Ahmed glaucoma-valve implant in patients with glaucoma, and the management of encapsulated cysts
    Eibschitz-Tsimhoni, M
    Schertzer, RM
    Lichter, PR
    Musch, DC
    Moroi, SE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S516 - S516
  • [10] A clinical study of the Ahmed glaucoma valve implant in advanced glaucoma
    Ayyala, RS
    Zurakowski, D
    Smith, JA
    Monshizadeh, R
    Netland, PA
    Richards, DW
    Layden, WE
    OPHTHALMOLOGY, 1998, 105 (10) : 1968 - 1976