Performance evaluation of a point of load for the upgrade of the ATLAS - LAr calorimeter

被引:2
|
作者
Lazzaroni, M. [1 ,2 ]
Citterio, M. [2 ]
Latorre, S. [2 ]
机构
[1] Univ Milan, Dipartimento Fis, Via G Celoria 16, I-20133 Milan, Italy
[2] Ist Nazl Fis Nucl, Via G Celoria 16, I-20133 Milan, Italy
关键词
Points of load; Measurement; LHC; High-B tolerance; Reliability; Dependability; Hostile environment; LHC; BEHAVIOR;
D O I
10.1016/j.measurement.2016.11.036
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper deals with the magnetic field (often denoted also as B-field) behavior of Point of Load devices developed in order to meet the requirement in term of magnetic field and radiation hardness mandatory for experiments operating at LHC. Devices have been tested under magnetic field up to about 1.2 Tat the Laboratorio Acceleratori e Superconduttivita Applicata (LASA), a laboratory located in Milan (Italy). The obtained experimental results are here presented in detail and, finally, discussed. The device here used has been designed to meet the stringent specification given for experiments at LHC taking also into account the planned upgrade for the denoted High Luminosity LHC (HL-LHC). The ability to operate in the hostile environment of the device presented in this paper (a DC-DC converter) is very interesting especially when the device is used in measurement systems: such as the Liquid Argon Calorimeter (LAr) of the ATLAS experiment at CERN. In this case, in fact, the simultaneous presence of radiation and strong static magnetic fields impose particularly harsh working conditions to semiconductor devices, for the presence of radiation, and to the coils, for the presence of magnetic field. In this paper, the experimental results obtained during the tests planned to verify the capability to work in hostile environment of a particular device designed by a research group at CERN has been presented. Details on trend of the output voltage, ripple, efficiency of the device are given and discussed. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:205 / 220
页数:16
相关论文
共 50 条
  • [41] Electronic Calibration of the ATLAS LAr Calorimeter and commissioning with Cosmic Muon Signals
    Gabaldon, Carolina
    XIII INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2009, 160
  • [42] Phase-II readout electronics upgrades of the ATLAS LAr calorimeter
    Anelli, Christopher
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 274 - 277
  • [43] A readout driver for the ATLAS LAr-calorimeter at a High Luminosity LHC
    Kielburg-Jeka, A.
    Staerz, S.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [44] Performance of a remote High Voltage power supply for the Phase II upgrade of the ATLAS Tile Calorimeter
    Vazeille, F.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [45] Upgrade of the ATLAS hadronic Tile Calorimeter for the High luminosity LHC
    Solodkov, A.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [47] Upgrade of the ATLAS Hadronic Tile Calorimeter for the High Luminosity LHC
    Tortajada, Ignacio Asensi
    ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA 2017), 2018, 170
  • [48] Upgrade of ATLAS hadronic Tile Calorimeter for the High Luminosity LHC
    Leone, Sandra
    JOURNAL OF INSTRUMENTATION, 2024, 19 (01):
  • [49] Upgrade of ATLAS Hadronic Tile Calorimeter for the High Luminosity LHC
    Delegido, Antonio Jesus Gomez
    ATLAS Tile Calorimeter System
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1047
  • [50] Upgrade of ATLAS Hadronic Tile Calorimeter for the High Luminosity LHC
    Mckenzie, Ryan
    NINTH ANNUAL CONFERENCE ON LARGE HADRON COLLIDER PHYSICS, LHCP2021, 2021,