DESIGN AND FABRICATION OF A MICROCANTILEVER-BASED SENSOR FOR NERVE GAS DETECTION

被引:0
|
作者
Li, Chengzhang [1 ]
Miller, Michele H. [1 ]
Nayyar, Jaspreet Singh
Velayudham, Singaravelu
Bergstrom, Paul L.
Liu, Haiying
机构
[1] Michigan Technol Univ, Dept Mech Engn, Houghton, MI 49931 USA
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Surface-micromachined MEMS processes were used to fabricate this gas sensor. We fabricated a variety of designs, including those with one end fixed, two ends fixed and four ends fixed. In addition to the first bending mode, the torsional mode is being used for sensing and actuation. The placement of air venting holes as well as the placement of the sensing and actuating electrodes have been varied in the designs. A custom polymer layer (PPE-1-LBS) that absorbs the nerve gas analog DMMP is applied to the surface of goldcoated microcantilevers. The polymer coating is applied just after the cantilever is released with hydrofluoric acid but before the drying process. This paper describes the important steps in the fabrication process and compares the manufacturability of the various cantilever designs. It also compares the expected performance of four types of designs.
引用
收藏
页码:627 / 634
页数:8
相关论文
共 50 条
  • [31] 3,4-Methylenedioxymethylamphetamine detection using a microcantilever-based biosensor
    Tseng, You-Chen
    Chang, Jeng-Shian
    Lin, Shiming
    Chao, Sheng D.
    Liu, Chih-Hao
    SENSORS AND ACTUATORS A-PHYSICAL, 2012, 182 : 163 - 167
  • [32] Microcantilever-based platforms as biosensing tools
    Alvarez, Mar
    Lechuga, Laura M.
    ANALYST, 2010, 135 (05) : 827 - 836
  • [33] The effect of flow velocity on microcantilever-based biosensors
    Wu, M. -C.
    Chang, J. -S.
    Wu, K. -C.
    Lin, C. -H.
    Wu, C. -Y.
    JOURNAL OF MECHANICS, 2007, 23 (04) : 353 - 358
  • [34] Highly sensitive microcantilever-based immunosensor for the detection of carbofuran in soil and vegetable samples
    Dai, Yingping
    Wang, Ting
    Hu, Xiaoya
    Liu, Shuzhao
    Zhang, Ming
    Wang, Chengyin
    FOOD CHEMISTRY, 2017, 229 : 432 - 438
  • [35] Simple and sensitive method of microcantilever-based DNA detection using nanoparticles conjugates
    Cha, Byung Hak
    Lee, Sang-Myung
    Hwang, Kyo Seon
    Kim, Sang Kyung
    Lee, Yoon-Sik
    Ju, Byeong-Kwon
    Kim, Tae Song
    2008 3RD IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1-3, 2008, : 160 - 160
  • [36] Rapid and Reliable Calibration of Laser Beam Deflection System for Microcantilever-Based Sensor Setups
    Mishra, Rohit
    Grange, Wilfried
    Hegner, Martin
    JOURNAL OF SENSORS, 2012, 2012
  • [37] Microcantilever-Based Hydrogen Sensors: Fabrication, Response Dynamics, and Squeeze Film Damping Study
    Verma, Hemant Kumar
    Shekhawat, Roopali
    Kandpal, Manoj
    Singh, Jaspreet
    Naik, Akshay
    2024 IEEE APPLIED SENSING CONFERENCE, APSCON, 2024,
  • [38] Image Processing System Design for Microcantilever-Based Optical Readout Infrared Arrays
    Tong, Qiang
    Dong, Liquan
    Zhao, Yuejin
    Gong, Cheng
    Liu, Xiaohua
    Yu, Xiaomei
    Yang, Lei
    Liu, Weiyu
    INFRARED, MILLIMETER-WAVE, AND TERAHERTZ TECHNOLOGIES II, 2012, 8562
  • [39] Piezoresistive microcantilever-based DNA sensor for sensitive detection of pathogenic Vibrio cholerae O1 in food sample
    Khemthongcharoen, Numfon
    Wonglumsom, Wijit
    Suppat, Assawapong
    Jaruwongrungsee, Kata
    Tuantranont, Adisorn
    Promptmas, Chamras
    BIOSENSORS & BIOELECTRONICS, 2015, 63 : 347 - 353
  • [40] Characterization and analytical validation of a microcantilever-based sensor for the determination of total carbonate in soil samples
    Plata, M. R.
    Hernando, J.
    Zougagh, M.
    Contento, A. M.
    Villasenor, M. J.
    Sanchez-Rojas, J. L.
    Rios, A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (01) : 245 - 251