Validation of a liquid chromatography-tandem mass spectrometry method to enable quantification of 3-iodothyronamine from serum

被引:19
|
作者
DeBarber, Andrea E. [1 ]
Geraci, Travis [1 ]
Colasurdo, Vincent P. [1 ]
Hackenmueller, Sarah A. [1 ]
Scanlan, Thomas S. [1 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Physiol & Pharmacol, Portland, OR 97239 USA
关键词
3-Iodothyronamine; LC-MS/MS; Serum;
D O I
10.1016/j.chroma.2008.09.022
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
There is great interest lately in the availability of analytical methods for quantification of 3-iodothyronamine from blood and tissues. To date, no validated method for determination of 3-iodothyronamine from biological matrices has been described. Detailed in this report is an LC-MS/MS method that permits accurate and reproducible quantification of pharmacological concentrations of 3-iodothyronamine from rat serum, with a 0.0008 M lower limit of quantification. Endogenous 3-iodothyronamine was observed from rodent and human serum (0.2 mL) at the method limit of detection. In summary, the LC-MS/MS method enables quantification of circulating 3-iodothyronamine to allow examination of a relationship with biological activity. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 59
页数:5
相关论文
共 50 条
  • [1] Identification and quantification of 3-iodothyronamine metabolites in mouse serum using liquid chromatography-tandem mass spectrometry
    Hackenmueller, Sarah A.
    Scanlan, Thomas S.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1256 : 89 - 97
  • [2] Quantification and Validation of Ertapenem Using a Liquid Chromatography-Tandem Mass Spectrometry Method
    van Rijn, S. P.
    Wessels, A. M. A.
    Greijdanus, B.
    Touw, D. J.
    Alffenaar, J. W. C.
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2014, 58 (06) : 3481 - 3484
  • [3] Determination of 3-iodothyronamine (3-T 1 AM) in mouse liver using liquid chromatography-tandem mass spectrometry
    Li, Zhong-Min
    Miller, Manuel
    Gachkar, Sogol
    Mittag, Jens
    Schriever, Sonja C.
    Pfluger, Paul T.
    Schramm, Karl-Werner
    De Angelis, Meri
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1165
  • [4] Quantification and validation of a liquid chromatography-tandem mass spectrometry assay for serum busulfan levels
    Ekremoglu, M.
    Kurdoglu, E. E.
    Oktem, M.
    [J]. FEBS JOURNAL, 2013, 280 : 279 - 279
  • [5] 3-Iodothyronamine cardiac metabolism: new insights resulting from liquid chromatography tandem mass spectrometry analysis
    Chiellini, G.
    Ghelardoni, S.
    Saba, A.
    Marchini, M.
    Frascarelli, S.
    Raffaelli, A.
    Scanlan, T. S.
    Zucchi, R.
    [J]. CARDIOVASCULAR RESEARCH, 2010, 87 : S118 - S118
  • [6] Validation of a method for quantification of ketobemidone in human plasma with liquid chromatography-tandem mass spectrometry
    Lampinen, M
    Bondesson, U
    Fredriksson, E
    Hedeland, M
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 789 (02): : 347 - 354
  • [7] Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for Quantification of Glycopyrrolate in Horse Plasma
    Rumpler, M. J.
    Sams, R. A.
    Colahan, P.
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2011, 35 (09) : 656 - 664
  • [8] Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of serum perfluorooctanoic acid and perfluorooctane sulfonate
    Kim, S.
    Nam, H.
    Han, J.
    Lee, E.
    [J]. CLINICA CHIMICA ACTA, 2022, 530 : S120 - S120
  • [9] Liquid chromatography-tandem mass spectrometry for the quantification of total testosterone in serum
    Shi, H.
    Carlow, D.
    [J]. CLINICAL CHEMISTRY, 2008, 54 (06) : A15 - A16
  • [10] Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of opiorphin in human saliva
    Brkljacic, Lidija
    Sabalic, Maja
    Salaric, Ivan
    Jeric, Ivanka
    Alajbeg, Ivan
    Nemet, Ina
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (32): : 3920 - 3926