Characterization of novel intramedullary nailing method for treating femoral shaft fracture through finite element analysis

被引:16
|
作者
Cui, Yunwei [1 ]
Xing, Wenzhao [2 ]
Pan, Zhenhua [2 ]
Kong, Zhigang [2 ]
Sun, Liang [2 ]
Sun, Lei [2 ]
Cheng, Xiaodong [1 ]
Liu, Changcheng [2 ]
机构
[1] Hebei Med Univ, Hosp 3, Key Lab Biomech Hebei Prov, Shijiazhuang 050051, Hebei, Peoples R China
[2] Hebei Med Univ, Dept Orthopaed Surg, Hosp 3, 139 Ziqiang Rd, Shijiazhuang 050051, Hebei, Peoples R China
关键词
femoral shaft fracture; intramedullary nail; displacement; stress; finite element; STRESS; FEMUR;
D O I
10.3892/etm.2020.8763
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Femoral shaft fracture is one of the most common types of fracture encountered in the clinic. For certain complex femoral shaft fractures, the traditional intramedullary nail may not provide sufficient stability. Therefore, novel intramedullary nail systems are required. The femur 3D model and the internal fixation model were designed using Mimics 17.0 (Materialise), Geomagic Studio 2012 (Raindrop) and Solidwork 2016 (Dassault) software. The validity of the models was verified through comparison with previous datain silico. To further simulate the comminuted femoral shaft fracture, the novel and traditional type of intramedullary nail system were included in the finite element analysis with the software. The displacement and stress distribution of the two internal fixations were compared using Abaqus 6.14 (Dassault) software. The effectiveness of the model was verified. The stress at the fixed end of the novel intramedullary nail system was greater than that at the fixed end of the traditional intramedullary nail system. However, the displacement of the novel intramedullary nail method was smaller than that of the traditional intramedullary nail. The novel intramedullary nail system features good stability and stress stimulation at the broken end, which is beneficial for bone healing. The present study may provide a theoretical basis for the selection of a means of internal fixation in the clinic.
引用
收藏
页码:748 / 753
页数:6
相关论文
共 50 条
  • [41] INTRAMEDULLARY NAILING OF ACUTE FEMORAL-SHAFT FRACTURES USING MANUAL TRACTION WITHOUT A FRACTURE TABLE
    KARPOS, PAG
    MCFERRAN, MA
    JOHNSON, KD
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1995, 9 (01) : 57 - 62
  • [42] PROPHYLACTIC INTRAMEDULLARY NAILING OF BISPHOSPHONATE RELATED BILATERAL SEQUENTIAL ATYPICAL FEMORAL SHAFT FRACTURE: A TREATMENT STRATEGY
    Rudrappa, Girish H.
    Won, Ye Yeon
    Yaligod, Vishwanath
    Shivanna, Umesh M.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (51): : 12023 - 12031
  • [43] A comparison of intramedullary nailing and plate-screw fixation in the treatment for ipsilateral fracture of the hip and femoral shaft
    Kesemenli C.C.
    Tosun B.
    Kim N.S.Y.
    MUSCULOSKELETAL SURGERY, 2012, 96 (2) : 117 - 124
  • [44] Closed, locked intramedullary nailing of pediatric femoral shaft fractures through the tip of the greater trochanter
    Kanellopoulos, AD
    Yiannakopoulos, CK
    Soucacos, PN
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (01): : 217 - 222
  • [45] Effect of Intramedullary Nailing Patterns on Interfragmentary Strain in a Mouse Femur Fracture: A Parametric Finite Element Analysis
    Lowen, Gregory B.
    Garrett, Katherine A.
    Moore-Lotridge, Stephanie N.
    Uppuganti, Sasidhar
    Guelcher, Scott A.
    Schoenecker, Jonathan G.
    Nyman, Jeffry S.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2022, 144 (05):
  • [46] Acute respiratory distress syndrome after treating ipsilateral femoral shaft and neck fracture with reamed intramedullary nailing in an asymptomatic COVID-19 patient
    Jun, Chungmu
    Cho, Young-Jae
    Quinn, Patrick Michael
    Song, Suk-Kyoon
    SAGE OPEN MEDICAL CASE REPORTS, 2023, 11
  • [47] Augmentative compression plating versus exchanging reamed nailing for nonunion of femoral shaft fracture after intramedullary nailing : A retrospective cohort study
    Ru, Jiangying
    Xu, Haidong
    Kang, Wenbo
    Cang, Haibin
    Niu, Yunfei
    Zhao, Jianning
    ACTA ORTHOPAEDICA BELGICA, 2016, 82 (02): : 249 - 257
  • [48] Breakage of the radiopaque wire from the medullary tube during closed antegrade intramedullary nailing for femoral shaft fracture
    Chan, Ping Keung
    Chan, Kwok Bill
    Lui, Tun Hing
    Ngai, Wai Kit
    JOURNAL OF ORTHOPAEDIC SURGERY, 2012, 20 (01) : 118 - 120
  • [49] INTRAMEDULLARY NAILING OF FEMORAL-SHAFT FRACTURES .2. FRACTURE-HEALING WITH STATIC INTERLOCKING FIXATION
    BRUMBACK, RJ
    UWAGIEERO, S
    LAKATOS, RP
    POKA, A
    BATHON, GH
    BURGESS, AR
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (10): : 1453 - 1462
  • [50] Intercondylar Fibrotic Lesion After Retrograde Intramedullary Nailing of a Femoral Shaft Fracture: A Case Report and Review of the Literature
    Boscariol, Rya
    Brunet, Jacques A.
    Dervin, Geoffrey F.
    JOURNAL OF KNEE SURGERY, 2013, 26 : S6 - S10