Spectroscopic Performance of DEPFET active Pixel Sensor Prototypes suitable for the high count rate Athena WFI Detector

被引:9
|
作者
Mueller-Seidlitz, Johannes [1 ]
Andritschke, Robert [1 ]
Baehr, Alexander [1 ]
Meidinger, Norbert [1 ]
Ott, Sabine [1 ]
Richter, Rainer H. [2 ]
Treberspurg, Wolfgang [1 ]
Treis, Johannes [2 ]
机构
[1] Max Planck Inst Extraterr Phys, Giessenbachstr 1, D-85748 Garching, Germany
[2] Max Planck Gesell, Semicond Lab, Otto Hahn Ring 6, D-81739 Munich, Germany
关键词
Athena WFI; DEPFET; Active pixel sensor; Infinipix; High count rate; X-ray astronomy;
D O I
10.1117/12.2235408
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The focal plane of the WFI of Athena consists of two sensors. One features a large field of view of 40' x 40' and one is forseen to be used for bright point like sources. Both parts base on DEPFET active pixel sensors. To fulfil the count rate requirement for the smaller sensor of less than 1% pile-up for a one Crab source it has to have a sufficient high frame rate. Since therefore the readout becomes a large fraction of the total photon integration time, the probability of measurements with incomplete signals increases. A shutter would solve the problem of these so called misfits but is not in agreement with the required high throughput of more than 80%. The Infinipix design has implemented a storage in addition to separate the collection and the readout of the charges without discarding them. Its working principle was successfully shown by Bahr et al.(1) on single pixel level. For the further development three layout variants were tested on a 32 x 32 pixel array scale. The measurements of the spectroscopic performance show very promising results even for the intended readout speed for the Athena WFI of 2.5 mu s per sensor row. Although, there are still layout and technology improvements necessary to ensure the reliability needed for space missions. In this paper we present the measurement results on the comparison of the three prototype layout variants.
引用
收藏
页数:7
相关论文
共 33 条
  • [31] A monolithic active pixel sensor with node-based, data-driven, parallel readout for the high energy physics experiment vertex detector
    Xiao, Le
    Dai, Wenjie
    Zhang, Guoxiang
    Zhou, Zijie
    You, Bihui
    Sun, Xiangming
    Huang, Guangming
    Gao, Chaosong
    Zhao, Cong
    Yang, Ping
    Liu, Jiajia
    Guo, Di
    Lu, Yunpeng
    Zhou, Yang
    Zhang, Ying
    Xie, Lirong
    Yang, Ming
    Yi, Liwen
    Tong, Qiaomu
    Feng, Wanhan
    Tian, Ziyang
    JOURNAL OF INSTRUMENTATION, 2024, 19 (02)
  • [32] Comparison of pulse shape discrimination performance of stilbene and liquid scintillator under high count-rate active interrogation conditions
    Langeveld, Willem G. J.
    Glenn, Andrew M.
    Sheets, Steven A.
    Strellis, Dan A.
    Zaitseva, Natalia P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954
  • [33] Performance of a four-element Si drift detector for X-ray absorption fine-structure spectroscopy: resolution, maximum count rate, and dead-time correction with incorporation into the ATHENA data analysis software
    Woicik, J. C.
    Ravel, B.
    Fischer, D. A.
    Newburgh, W. J.
    JOURNAL OF SYNCHROTRON RADIATION, 2010, 17 : 409 - 413