Spectroscopic Performance of DEPFET active Pixel Sensor Prototypes suitable for the high count rate Athena WFI Detector

被引:9
|
作者
Mueller-Seidlitz, Johannes [1 ]
Andritschke, Robert [1 ]
Baehr, Alexander [1 ]
Meidinger, Norbert [1 ]
Ott, Sabine [1 ]
Richter, Rainer H. [2 ]
Treberspurg, Wolfgang [1 ]
Treis, Johannes [2 ]
机构
[1] Max Planck Inst Extraterr Phys, Giessenbachstr 1, D-85748 Garching, Germany
[2] Max Planck Gesell, Semicond Lab, Otto Hahn Ring 6, D-81739 Munich, Germany
关键词
Athena WFI; DEPFET; Active pixel sensor; Infinipix; High count rate; X-ray astronomy;
D O I
10.1117/12.2235408
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The focal plane of the WFI of Athena consists of two sensors. One features a large field of view of 40' x 40' and one is forseen to be used for bright point like sources. Both parts base on DEPFET active pixel sensors. To fulfil the count rate requirement for the smaller sensor of less than 1% pile-up for a one Crab source it has to have a sufficient high frame rate. Since therefore the readout becomes a large fraction of the total photon integration time, the probability of measurements with incomplete signals increases. A shutter would solve the problem of these so called misfits but is not in agreement with the required high throughput of more than 80%. The Infinipix design has implemented a storage in addition to separate the collection and the readout of the charges without discarding them. Its working principle was successfully shown by Bahr et al.(1) on single pixel level. For the further development three layout variants were tested on a 32 x 32 pixel array scale. The measurements of the spectroscopic performance show very promising results even for the intended readout speed for the Athena WFI of 2.5 mu s per sensor row. Although, there are still layout and technology improvements necessary to ensure the reliability needed for space missions. In this paper we present the measurement results on the comparison of the three prototype layout variants.
引用
收藏
页数:7
相关论文
共 33 条
  • [1] Characterization of a 256 x 256 pixel DEPFET detector for the WFI of Athena
    Treberspurg, W.
    Andritschke, R.
    Behrens, A.
    Bonholzer, M.
    Emberger, V.
    Hauser, G.
    Lechner, P.
    Meidinger, N.
    Mueller-Seidlitz, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 958
  • [2] Spectroscopic performance of flight-like DEPFET sensors for Athena's WFI
    Mueller-Seidlitz, J.
    Andritschke, R.
    Bonholzer, M.
    Emberger, V
    Hauser, G.
    Herrmann, M.
    Lechner, P.
    Mayr, A.
    Oser, J.
    SPACE TELESCOPES AND INSTRUMENTATION 2022: ULTRAVIOLET TO GAMMA RAY, 2022, 12181
  • [3] The DEPFET Active Pixel Sensor as Vertex Detector for the ILC
    Fischer, P.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 956 - 962
  • [4] First results of DEPFET based active pixel sensor prototypes for the XEUS wide field imager
    Treis, J
    Fischer, P
    Hälker, O
    Harter, M
    Herrmann, S
    Kohrs, R
    Krüger, H
    Lechner, P
    Lutz, G
    Peric, I
    Porro, M
    Richter, RH
    Strüder, L
    Trimpl, M
    Wermes, N
    HIGH-ENERGY DETECTORS IN ASTRONOMY, 2004, 5501 : 89 - 100
  • [5] Prospects and limitations of DEPFET active pixel sensors as high speed spectroscopic X-ray imager for the ATHENA Wide Field Imager
    Aschauer, S.
    Baehr, A.
    Lutz, G.
    Majewski, P.
    Strueder, L.
    Treis, J.
    SPACE TELESCOPES AND INSTRUMENTATION 2014: ULTRAVIOLET TO GAMMA RAY, 2014, 9144
  • [6] Characterization results of the first small pixel high rate (SPHIRD) pixel detector prototypes
    Magalhaes, Debora
    Fajardo, Pablo
    Grybos, Pawel
    Kleczek, Rafal
    Kmon, Piotr
    Otfinowsk, Piotr
    Ruat, Marie
    JOURNAL OF INSTRUMENTATION, 2023, 18 (12):
  • [7] Performance of ALICE silicon pixel detector prototypes in high energy beams
    Elia, D.
    Anelli, G.
    Antinori, F.
    Badala, A.
    Bruno, G. E.
    Burns, M.
    Cali, I. A.
    Campbell, M.
    Caselle, M.
    Ceresa, S.
    Chochula, P.
    Cinausero, M.
    Conrad, J.
    Dima, R.
    Fabris, D.
    Fini, R. A.
    Fioretto, E.
    Kapusta, S.
    Kluge, A.
    Krivda, M.
    Lenti, V.
    Librizzi, F.
    Lunardon, M.
    Manzari, V.
    Morel, M.
    Moretto, S.
    Nilsson, P.
    Osmic, F.
    Pappalardo, G. S.
    Paticchio, V.
    Pepato, A.
    Prete, G.
    Pulvirenti, A.
    Riedler, P.
    Riggi, F.
    Sandor, L.
    Santoro, R.
    Scarlassara, F.
    Segato, G.
    Soramel, F.
    Stefanini, G.
    de Matos, C. Torcato
    Turrisi, R.
    Vannucci, L.
    Viesti, G.
    Virgili, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 565 (01): : 30 - 35
  • [8] Development of DEPFET active pixel sensors to improve the spectroscopic response for high time resolution applications
    Baehr, Alexander
    Aschauer, Stefan
    Bergbauer, Bettina
    Lechner, Peter H.
    Majewski, Petra
    Meidinger, Norbert
    Ott, Sabine M.
    Porro, Matteo
    Richter, Rainer H.
    Strueder, Lothar
    Treis, Johannes
    SPACE TELESCOPES AND INSTRUMENTATION 2014: ULTRAVIOLET TO GAMMA RAY, 2014, 9144
  • [9] Performance and applications of a high rate imaging pixel detector
    Pavel, NA
    Besch, HJ
    Menk, R
    Sarvestani, A
    Sauer, N
    Stiehler, R
    Walenta, AH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3): : 313 - 316
  • [10] Performance of a Medipix3RX Spectroscopic Pixel Detector With a High Resistivity Gallium Arsenide Sensor
    Hamann, Elias
    Koenig, Thomas
    Zuber, Marcus
    Cecilia, Angelica
    Tyazhev, Anton
    Tolbanov, Oleg
    Procz, Simon
    Fauler, Alex
    Baumbach, Tilo
    Fiederle, Michael
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (03) : 707 - 715