Study of the Fire Resistance Performance of a Kind of Steel Fire Door

被引:3
|
作者
Wu Xin [1 ,2 ]
Liu Jian-yong [1 ,2 ]
Zhao Xia [1 ,2 ]
Yang Zhan [1 ,2 ]
Xu Ran [3 ]
机构
[1] Guangdong Prov Entetprise Key Lab Mat & Elements, Guangzhou 510663, Guangdong, Peoples R China
[2] Guangzhou Bldg Mat Inst Ltd Co, Guangzhou 510663, Guangdong, Peoples R China
[3] UL CCIC Co Ltd, Guangzhou 510663, Guangdong, Peoples R China
关键词
uninsulated; steel fire door; fire resistance; hose stream test;
D O I
10.1016/j.proeng.2013.02.166
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A fire resistance test was carried out for a no infill steel fire door, base on the test data analysis and the observation, combined with relative standard to evaluate the fire resistant performance, this fire door has good integrity performance, but with poor insulation performance. (C) 2013 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:440 / 445
页数:6
相关论文
共 50 条
  • [21] FIRE RESISTANCE OF PROTECTED STEEL COLUMNS
    LIE, TT
    STANZAK, WW
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1973, 10 (03): : 82 - 94
  • [22] FIRE RESISTANCE OF COLUMNS IN STEEL FRAMES
    FRANSSEN, JM
    DOTREPPE, JC
    FIRE SAFETY JOURNAL, 1992, 19 (2-3) : 159 - 175
  • [23] FIRE RESISTANCE OF SOLID STEEL COLUMNS
    KLINGSCH, W
    FIRE SAFETY JOURNAL, 1982, 4 (04) : 237 - 241
  • [24] FIRE RESISTANCE OF PROTECTED STEEL COLUMNS
    STETINA, HJ
    LIE, TT
    STANZAK, WW
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1973, 10 (04): : 134 - 136
  • [25] FIRE RESISTANCE OF STRUCTURAL-STEEL
    LIE, TT
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1978, 15 (04): : 116 - 125
  • [26] Resistance to fire of silicone-based coatings: Fire protection of steel against cellulosic fire
    Gardelle, Bastien
    Duquesne, Sophie
    Vandereecken, Patrick
    Bourbigot, Serge
    JOURNAL OF FIRE SCIENCES, 2014, 32 (04) : 374 - 387
  • [27] Fire resistance of composite slabs with steel deck under natural fire
    Piloto, Paulo A. G.
    Balsa, Carlos
    Macedo Gomes, Felipe Macedo
    Matias, Bergson
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2021, 12 (04) : 522 - 540
  • [28] On the Simulation of Real Fire for Post Fire Resistance Evaluation of Steel Structures
    Tom Molkens
    Barbara Rossi
    Fire Technology, 2021, 57 : 839 - 871
  • [29] On the Simulation of Real Fire for Post Fire Resistance Evaluation of Steel Structures
    Molkens, Tom
    Rossi, Barbara
    FIRE TECHNOLOGY, 2021, 57 (02) : 839 - 871
  • [30] Fire resistance of steel shear connections
    Selamet, Serdar
    Garlock, Maria E.
    FIRE SAFETY JOURNAL, 2014, 68 : 52 - 60