Usefulness of a Virtual Reality Percutaneous Trigeminal Rhizotomy Simulator in Neurosurgical Training

被引:30
|
作者
Shakur, Sophia F. [1 ]
Luciano, Cristian J. [2 ,3 ]
Kania, Patrick [3 ]
Roitberg, Ben Z. [4 ]
Banerjee, P. Pat [2 ,3 ]
Slavin, Konstantin V. [1 ]
Sorenson, Jeffrey [5 ]
Charbel, Fady T. [1 ,3 ]
Alaraj, Ali [1 ]
机构
[1] Univ Illinois, Dept Neurosurg, Chicago, IL 60612 USA
[2] Univ Illinois, Dept Mech & Ind Engn, Chicago, IL 60612 USA
[3] Immers Touch Inc, Westmont, IL USA
[4] Univ Chicago, Dept Surg, Neurosurg Sect, Chicago, IL 60637 USA
[5] Semmes Murphey Neurol & Spine Inst, Memphis, TN USA
关键词
Haptic; Resident; Rhizotomy; Simulator; Trigeminal; Virtual reality; FORAMEN OVALE; EDUCATION; COMPLICATIONS; PLACEMENT;
D O I
10.1227/NEU.0000000000000853
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Simulation-based training may be incorporated into neurosurgery in the future. OBJECTIVE: To assess the usefulness of a novel haptics-based virtual reality percutaneous trigeminal rhizotomy simulator. METHODS: A real-time augmented reality simulator for percutaneous trigeminal rhizotomy was developed using the ImmersiveTouch platform. Ninety-two neurosurgery residents tested the simulator at American Association of Neurological Surgeons Top Gun 2014. Postgraduate year (PGY), number of fluoroscopy shots, the distance from the ideal entry point, and the distance from the ideal target were recorded by the system during each simulation session. Final performance score was calculated considering the number of fluoroscopy shots and distances from entry and target points (a lower score is better). The impact of PGY level on residents' performance was analyzed. RESULTS: Seventy-one residents provided their PGY-level and simulator performance data; 38% were senior residents and 62% were junior residents. The mean distance from the entry point (9.4 mm vs 12.6 mm, P = .01), the distance from the target (12.0 mm vs 15.2 mm, P = .16), and final score (31.1 vs 37.7, P = .02) were lower in senior than in junior residents. The mean number of fluoroscopy shots (9.8 vs 10.0, P = .88) was similar in these 2 groups. Linear regression analysis showed that increasing PGY level is significantly associated with a decreased distance from the ideal entry point (P = .001), a shorter distance from target (P = .05), a better final score (P = .007), but not number of fluoroscopy shots (P = .52). CONCLUSION: Because technical performance of percutaneous rhizotomy increases with training, we proposed that the skills in performing the procedure in our virtual reality model would also increase with PGY level, if our simulator models the actual procedure. Our results confirm this hypothesis and demonstrate construct validity.
引用
收藏
页码:420 / 425
页数:6
相关论文
共 50 条
  • [41] Evaluation of a Haptic Virtual Reality Simulator for Endodontics Training
    Bogoni, Tales
    Pinho, Marcio
    Scarparo, Roberta
    [J]. 30TH ANNUAL ACM SYMPOSIUM ON APPLIED COMPUTING, VOLS I AND II, 2015, : 267 - 269
  • [42] A virtual reality based simulator for gynecologic exam training
    Moraes, Ronei M.
    Souza, Daniel F. L.
    Valdek, Milane C. O.
    Machado, Liliane S.
    [J]. 2006 7TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY BASED HIGHER EDUCATION AND TRAINING, VOLS 1 AND 2, 2006, : 816 - 821
  • [43] Use of a virtual reality simulator for ureteroscopy training - Comment
    Teichman, JMH
    [J]. JOURNAL OF UROLOGY, 2004, 171 (01): : 323 - 323
  • [44] Virtual Reality Simulator for Training in Myringotomy with Tube Placement
    Huang, Caiwen
    Agrawal, Sumit K.
    Ladak, Hanif M.
    [J]. JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2016, 36 (02) : 214 - 225
  • [45] A VIRTUAL REALITY SIMULATOR FOR TRAINING WRIST ARTHROSCOPIC SURGERY
    Yaacoub, Fadi
    Hamam, Yskandar
    Abche, Antoine
    [J]. HEALTHINF 2009: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON HEALTH INFORMATICS, 2009, : 74 - +
  • [46] Virtual reality simulator for training urologists on transurethral prostatectomy
    Zhu He
    Zhang Yi
    Liu Jin-shun
    Wang Gang
    Yu Cheng-fan
    Na Yan-qun
    [J]. CHINESE MEDICAL JOURNAL, 2013, 126 (07) : 1220 - 1223
  • [47] Development of plant training simulator based on virtual reality
    Sonoda, Yoshiaki
    Yoshimoto, Nobuya
    Morimura, Kouichi
    Nakatani, Takafumi
    Matsuzaki, Suemi
    [J]. Technical Review - Mitsubishi Heavy Industries, 2000, 37 (01): : 19 - 23
  • [48] Virtual reality simulator for training urologists on transurethral prostatectomy
    ZHU He
    ZHANG Yi
    LIU Jin-shun
    WANG Gang
    YU Cheng-fan
    NA Yan-qun
    [J]. 中华医学杂志(英文版), 2013, 126 (07) : 1220 - 1223
  • [49] The benefits of virtual reality simulator training for laparoscopic surgery
    Hart, Roger
    Karthigasu, Krishnan
    [J]. CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2007, 19 (04) : 297 - 302
  • [50] Virtual reality simulator for training and assessment of vitreoretinal surgeons
    Rossi, JV
    Verma, D
    Fujii, GY
    Lakhanpal, RR
    Panzan, CQ
    Yanai, D
    Wu, SL
    Humayun, MS
    de Juan, E
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U679 - U679