Development and characterization of a green fluorescent protein-based bacterial biosensor for bioavailable toluene and related compounds

被引:96
|
作者
Stiner, L
Halverson, LJ
机构
[1] Iowa State Univ Sci & Technol, Dept Agron, Ames, IA 50011 USA
[2] Iowa State Univ Sci & Technol, Dept Microbiol, Ames, IA 50011 USA
关键词
D O I
10.1128/AEM.68.4.1962-1971.2002
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A green fluorescent protein-based Pseudomonas fluorescens strain A506 biosensor was constructed and characterized for its potential to measure benzene, toluene, ethylbenzene, and related compounds in aqueous solutions. The biosensor is based on a plasmid carrying the toluene-benzene utilization (tbu) pathway transcriptional activator TbuT from Ralstonia pickettii PKO1 and a transcriptional fusion of its promoter PtbuA1 with a promoterless gfp gene on a broad-host-range promoter probe vector. TbuT was not limiting, since it was constitutively expressed by being fused to the neomycin phosphotransferase (nptII) promoter. The biosensor cells were readily induced, and fluorescence emission after induction periods of 3 h correlated well with toluene, benzene, ethylbenzene, and trichloroethylene concentrations. Our experiments using flow cytometry show that intermediate levels of gfp expression in response to toluene reflect uniform induction of cells. As the toluene concentration increases, the level of gfp expression per cell increases until saturation kinetics of the TbuT-PtbuA1 system are observed. Each inducer had a unique minimum concentration that was necessary for induction, with K-app values that ranged from 3.3 +/- 1.8 muM for toluene to 35.6 +/- 16.6 muM for trichloroethylene (means standard errors of the means), and maximal fluorescence response. The fluorescence response was specific for alkyl-substituted benzene derivatives and branched alkenes (di- and trichloroethylene, 2-methyl-2-butene). The biosensor responded in an additive fashion to the presence of multiple inducers and was unaffected by the presence of compounds that were not inducers, such as those present in gasoline. Flow cytometry revealed that, in response to toxic concentrations of gasoline, there was a small uninduced population and another larger fully induced population whose levels of fluorescence corresponded to the amount of effectors present in the sample. These results demonstrate the potential for green fluorescent protein-based bacterial biosensors to measure environmental contaminants.
引用
收藏
页码:1962 / 1971
页数:10
相关论文
共 50 条
  • [21] Green Fluorescent Protein-Based Biosensor To Detect and Quantify Stress Responses Induced by DNA-Degrading Colicins
    Abraham, Sam
    Chin, James
    Brouwers, Huub J. M.
    Turner, Bernadette
    Zhang, Ren
    Chapman, Toni A.
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2011, 77 (18) : 6691 - 6693
  • [22] Development of a green fluorescent protein reporter for a yeast genotoxicity biosensor
    Billinton, N
    Barker, MG
    Michel, CE
    Knight, AW
    Heyer, WD
    Goddard, NJ
    Fielden, PR
    Walmsley, RM
    [J]. BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8): : 831 - 838
  • [23] Green Fluorescent Protein-Based Viability Assay in a Multiparametric Configuration
    Csepregi, Rita
    Temesfoi, Viktoria
    Poor, Miklos
    Faust, Zsuzsanna
    Koszegi, Tamas
    [J]. MOLECULES, 2018, 23 (07):
  • [24] Highly efficient green fluorescent protein-based kinase substrates
    Yang, F
    Liu, Y
    Bixby, SD
    Friedman, JD
    Shokat, KM
    [J]. ANALYTICAL BIOCHEMISTRY, 1999, 266 (02) : 167 - 173
  • [25] Development of green fluorescent protein-based cAMP indicators for covering a wide range of cAMP concentrations
    Hiasa, Sohei
    Fujimori, Takeru
    Aiki, Saki
    Ueda, Hiroshi
    Tsuboi, Takashi
    Kitaguchi, Tetsuya
    [J]. RSC ADVANCES, 2023, 13 (23) : 15514 - 15520
  • [26] GREEN FLUORESCENT PROTEIN BASED MICROBIAL BIOSENSOR FOR BIPHENYL DEGRADATION
    Bholay, A. D.
    Hiren, Prajapati, V
    Shrikant, Dharaskar P.
    Vishal, Wagh A.
    [J]. INTERNATIONAL JOURNAL OF ADVANCED BIOTECHNOLOGY AND RESEARCH, 2013, 4 (04): : 437 - 443
  • [27] Development and testing of a bacterial biosensor for toluene-based environmental contaminants
    Dept. of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, United States
    不详
    不详
    不详
    [J]. Appl. Environ. Microbiol., 3 (1006-1012):
  • [28] Development and testing of a bacterial biosensor for toluene-based environmental contaminants
    Willardson, BM
    Wilkins, JF
    Rand, TA
    Schupp, JM
    Hill, KK
    Keim, P
    Jackson, PJ
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1998, 64 (03) : 1006 - 1012
  • [29] Development of a protein-based system for the detection of organophosphates using the pH-dependence of enhanced green fluorescent protein
    Harris, Jared D.
    Conway, Monique
    Adams, Clare M.
    Hounshell, Brandon
    Puckett, Libby G.
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [30] TracingLactobacillus plantarumwithin the intestinal tract of mice: green fluorescent protein-based fluorescent tagging
    Cui, Shumao
    Chen, Cailing
    Gu, Jiayu
    Mao, Bingyong
    Zhang, Hao
    Zhao, Jianxin
    Chen, Wei
    [J]. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2021, 101 (05) : 1758 - 1766