Fire Extinguishers: A Case Study of CFC Replacements (Part I)

被引:1
|
作者
Johnson, E. P. [1 ]
Clarke, E. K. [1 ]
Banks, R. E. [2 ]
Sharratt, P. N. [2 ]
机构
[1] Atlantic Consulting, Gb London N19 4NF, England
[2] UMIST, Manchester, Lancs, England
来源
关键词
Automobile air-conditioning; CFC alternatives; chlorofluorocarbons; eco-impact; fire extinguishers; fluorocarbons; global warming; HFC-227ea; fire extinguishing agent; LCA; Montreal Protocols; tetrafluoroethylene; TEWI; total equivalent warming impact (TEWI);
D O I
10.1007/BF02978805
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In some well-known TEWI (total equivalent warming impact) analyses of CFC alternatives, global warmer emissions in production have not been considered. The authors show that TEWI can be affected significantly by these production emissions, which suggests they should be considered in some TEWI analyses. The paper describes a TEWI analysis for one production sequence, that which leads from chloroform to tetrafluoroethylene and thence to HFC-227ea, a fire extinguishing agent. Numerous other commercial products stem from this sequence as well, including refrigerants, polymers and surfactants - these are summarised in the paper. Particular emphasis is placed on describing the production sequence and its global warming parameters to show that these can indeed be estimated from published information. The TEWI profile is presented at the close.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 50 条
  • [31] Modeling the collapse of the Plasco Building. Part I: Reconstruction of fire
    Khan, Aatif Ali
    Domada, Ramakanth Veera Venkata
    Huang, Xinyan
    Khan, Mustesin Ali
    Usmani, Asif
    BUILDING SIMULATION, 2022, 15 (04) : 583 - 596
  • [32] Modeling the collapse of the Plasco Building. Part I: Reconstruction of fire
    Aatif Ali Khan
    Ramakanth Veera Venkata Domada
    Xinyan Huang
    Mustesin Ali Khan
    Asif Usmani
    Building Simulation, 2022, 15 : 583 - 596
  • [33] Numerical modeling of sodium fire-Part I: Spray combustion
    Sathiah, Pratap
    Roelofs, Ferry
    NUCLEAR ENGINEERING AND DESIGN, 2014, 278 : 723 - 738
  • [34] Wind and Fire Coupled Modelling-Part I: Literature Review
    Wegrzynski, Wojciech
    Lipecki, Tomasz
    FIRE TECHNOLOGY, 2018, 54 (05) : 1405 - 1442
  • [35] Downslope Windstorms of San Diego County. Part I: A Case Study
    Cao, Yang
    Fovell, Robert G.
    MONTHLY WEATHER REVIEW, 2016, 144 (02) : 529 - 552
  • [36] Isopycnal averaging at constant height. Part I: The formulation and a case study
    Nurser, AJG
    Lee, MM
    JOURNAL OF PHYSICAL OCEANOGRAPHY, 2004, 34 (12) : 2721 - 2739
  • [37] Case study of performance evaluation of watertight of mortars and water repellents - Part I
    Herrmann, Thiana Dias
    Mohamad, Gihad
    Antocheves de Lima, Rogerio Cattelan
    da Silva Santos Neto, Almir Barros
    Lubeck, Andre
    MATERIA-RIO DE JANEIRO, 2019, 24 (04):
  • [38] Chronic Obstructive Pulmonary Disease in Older Adults Part I: Case Study
    Brandt, Nicole J.
    Cook, Heather
    JOURNAL OF GERONTOLOGICAL NURSING, 2018, 44 (07): : 10 - 14
  • [39] Influence of faulting on a mine shaft - a case study: part I - Background and instrumentation
    Bruneau, G
    Tyler, DB
    Hadjigeorgiou, J
    Potvin, Y
    INTERNATIONAL JOURNAL OF ROCK MECHANICS AND MINING SCIENCES, 2003, 40 (01) : 95 - 111
  • [40] Contaminant dispersion with personal displacement ventilation, Part I: Base case study
    Xu, Yue
    Yang, Xudong
    Yang, Caiqing
    Srebric, Jelena
    BUILDING AND ENVIRONMENT, 2009, 44 (10) : 2121 - 2128