Fire Extinguishers: A Case Study of CFC Replacements (Part I)

被引:1
|
作者
Johnson, E. P. [1 ]
Clarke, E. K. [1 ]
Banks, R. E. [2 ]
Sharratt, P. N. [2 ]
机构
[1] Atlantic Consulting, Gb London N19 4NF, England
[2] UMIST, Manchester, Lancs, England
来源
关键词
Automobile air-conditioning; CFC alternatives; chlorofluorocarbons; eco-impact; fire extinguishers; fluorocarbons; global warming; HFC-227ea; fire extinguishing agent; LCA; Montreal Protocols; tetrafluoroethylene; TEWI; total equivalent warming impact (TEWI);
D O I
10.1007/BF02978805
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In some well-known TEWI (total equivalent warming impact) analyses of CFC alternatives, global warmer emissions in production have not been considered. The authors show that TEWI can be affected significantly by these production emissions, which suggests they should be considered in some TEWI analyses. The paper describes a TEWI analysis for one production sequence, that which leads from chloroform to tetrafluoroethylene and thence to HFC-227ea, a fire extinguishing agent. Numerous other commercial products stem from this sequence as well, including refrigerants, polymers and surfactants - these are summarised in the paper. Particular emphasis is placed on describing the production sequence and its global warming parameters to show that these can indeed be estimated from published information. The TEWI profile is presented at the close.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 50 条
  • [1] Fire extinguishers: A case study of CFC replacements (part I)
    Atlantic Consulting, United Kingdom
    不详
    不详
    Int. J. Life Cycle Assess., 3 (135-140):
  • [2] Fire extinguishers: A case study of CFC replacements
    E. P. Johnson
    E. K. Clarke
    R. E. Banks
    P. N. Sharratt
    The International Journal of Life Cycle Assessment, 1997, 2 : 135 - 140
  • [3] Automobile air conditioning: A case study of CFC replacements. Part II
    Johnson E.P.
    Banks R.E.
    Sharratt P.N.
    The International Journal of Life Cycle Assessment, 1998, 3 (2) : 75 - 79
  • [4] A study of portable water mist fire extinguishers used for extinguishment of multiple fire types
    Liu, Zhigang
    Kim, Andrew K.
    Carpenter, Don
    FIRE SAFETY JOURNAL, 2007, 42 (01) : 25 - 42
  • [5] Optimal design of cause selecting control charts for monitoring the processes of coating fire extinguishers: A case study
    Duffuaa, Salih O.
    Attia, Ahmed M.
    Ghaithan, Ahmed M.
    QUALITY ENGINEERING, 2019, 31 (02) : 334 - 347
  • [6] EXPERIMENTAL STUDY ON ELECTRIFICATION PHENOMENA IN OPERATION OF FIRE EXTINGUISHERS FOR MARINE USE.
    Yamane
    Yoshida, Koujirou
    Senpaku Gijutsu Kenkyusho Hokoku/Papers of Ship Research Institute, 1988, 25 (01): : 11 - 33
  • [7] A SIMULATED STUDY ON THE EFFECT OF WATER TEMPERATURE ON COOLING EFFICIENCY OF WATER MIST FIRE EXTINGUISHERS
    Omidvar, Amir
    Mandavi, Amirhossein
    Mehryar, Reza
    JOURNAL OF THERMAL ENGINEERING, 2020, 6 (04): : 460 - 473
  • [8] Proteins and Peptides as Replacements for Traditional Organic Preservatives: Part I
    Hodges, Tyler W.
    Kemp, Lisa K.
    Mcinnis, Brittney M.
    Wilhelm, Kyle L.
    Hurt, Jonathan D.
    Mcdaniel, Steve
    Rawlins, James W.
    COATINGSTECH, 2018, 15 (04): : 44 - 50
  • [9] Road Planning in Europe - a Case Study (Part I)
    Rubel, Ruediger
    Silbermann, Eva L.
    JOURNAL FOR EUROPEAN ENVIRONMENTAL & PLANNING LAW, 2006, 3 (06) : 519 - 534
  • [10] Thermal conditions of an electronic device in case of fire First part: experimental study
    Chine, Bruno
    TECNOLOGIA EN MARCHA, 2007, 20 (04): : 51 - 58