Pulse oximetry screening for critical congenital heart defects in Ontario, Canada: a cost-effectiveness analysis

被引:9
|
作者
Mukerji, Amit [1 ]
Shafey, Amy [2 ]
Jain, Amish [3 ]
Cohen, Eyal [3 ,4 ]
Shah, Prakesh S. [3 ,4 ]
Sander, Beate [4 ,5 ]
Shah, Vibhuti [3 ,4 ]
机构
[1] McMaster Univ, Dept Pediat, Hamilton, ON, Canada
[2] Univ Calgary, Dept Pediat, Calgary, AB, Canada
[3] Univ Toronto, Dept Pediat, Toronto, ON, Canada
[4] Univ Toronto, Inst Hlth Policy Management & Evaluat, Toronto, ON, Canada
[5] Univ Hlth Network, Toronto Gen Hosp, Res Inst, Toronto, ON, Canada
关键词
Saturation screening; Cost-utility analysis; Health economics; Utility; Cost-effectiveness threshold; DISEASE; MORTALITY;
D O I
10.17269/s41997-019-00280-7
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objective Previously conducted cost-effectiveness analyses of pulse oximetry screening (POS) for critical congenital heart defects (CCHDs) have shown it to be a cost-effective endeavour, but the geographical setting of Ontario in relation to its vast yet sparsely populated regions presents unique challenges. The objective of this study was to estimate the cost-effectiveness of POS for CCHD in Ontario, Canada. Methods A cost-effectiveness analysis, comparing POS to no POS, was conducted from the Ontario healthcare payer perspective using a Markov model. The base case was defined as a well-appearing newborn at 24 h of age. Outcome measures, including quality-adjusted life months (QALMs), lifetime costs, and incremental cost-effectiveness ratios (ICER) [Delta Cost/Delta QALMs], were calculated over a lifetime horizon. All outcomes were discounted at 1.5% per year. Cost-effectiveness was assessed using an a priori ICER threshold of CAD$4166.67 per QALM (equivalent to CAD$50,000 per quality-adjusted life year). Deterministic and probabilistic sensitivity analyses were conducted to assess parameter uncertainty. Results Implementation of POS is expected to lead to timely diagnosis of 51 CCHD cases annually. The incremental cost of performing POS was estimated to be $27.27 per screened individual, with a gain of 0.02455 QALMs. This yielded an ICER of CAD$1110.79 per QALM, well below the pre-determined threshold. The probabilistic sensitivity analysis estimated a 92.3% chance of routine implementation of POS being cost-effective. Conclusion Routine implementation of POS for CCHD in Ontario is expected to be cost-effective.
引用
收藏
页码:804 / 811
页数:8
相关论文
共 50 条
  • [21] Screening for Critical Congenital Heart Defects with Pulse Oximetry: Medical Aspects
    Ewer, Andrew K.
    AMERICAN JOURNAL OF PERINATOLOGY, 2016, 33 (11) : 1062 - 1066
  • [22] Pulse Oximetry Screening for Critical Congenital Heart Defects in Newborn Babies
    Girdhar, Anurag
    Ewer, Andrew K.
    CRITICAL CARE NURSING CLINICS OF NORTH AMERICA, 2024, 36 (01) : 99 - 110
  • [23] Reply to Commentary on "Pulse Oximetry Screening for Critical Congenital Heart Defects"
    Ewer, Andrew K.
    Thangaratinam, Shakila
    Plana, Nieves
    Zamora, Javier
    NEONATOLOGY, 2019, 116 (04) : 390 - 391
  • [24] Pulse oximetry as a screening tool for critical congenital heart defects in newborns
    Shahzad, Muhammad
    Waqar, Talal
    Waheed, Khawaja Ahmad Irfan
    Gul, Rafia
    Fatima, Syeda Tahseen
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2017, 67 (08) : 1220 - 1223
  • [25] Feasibility of pulse oximetry screening for critical congenital heart defects in homebirths
    Cawsey, M. J.
    Noble, S.
    Cross-Sudworth, F.
    Ewer, A. K.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2016, 101 (04): : F349 - F351
  • [26] Pulse oximetry screening for congenital heart defects
    Ewer, Andrew K.
    Granelli, Anne De-Wahl
    Manzoni, Paolo
    Sanchez Luna, Manuel
    Martin, Gerard R.
    LANCET, 2013, 382 (9895): : 856 - 857
  • [27] Pulse oximetry as a screening test for congenital heart defects in newborn infants: a test accuracy study with evaluation of acceptability and cost-effectiveness
    Ewer, A. K.
    Furmston, A. T.
    Middleton, L. J.
    Deeks, J. J.
    Daniels, J. P.
    Pattison, H. M.
    Powell, R.
    Roberts, T. E.
    Barton, P.
    Auguste, P.
    Bhoyar, A.
    Thangaratinam, S.
    Tonks, A. M.
    Satodia, P.
    Deshpande, S.
    Kumararatne, B.
    Sivakumar, S.
    Mupanemunda, R.
    Khan, K. S.
    HEALTH TECHNOLOGY ASSESSMENT, 2012, 16 (02) : 1 - +
  • [28] Pulse oximetry screening for critical congenital heart defects: a UK national survey
    Singh, Anju
    Ewer, Andrew K.
    LANCET, 2013, 381 (9866): : 535 - 535
  • [29] Pulse oximetry screening as a complementary strategy to detect critical congenital heart defects
    Meberg, Alf
    Andreassen, Andreas
    Brunvand, Leif
    Markestad, Trond
    Moster, Dag
    Nietsch, Lutz
    Silberg, Inger Elisabeth
    Skalevik, Jan Einar
    ACTA PAEDIATRICA, 2009, 98 (04) : 682 - 686
  • [30] Pulse oximetry screening for critical congenital heart defects: a European consensus statement
    Manzoni, Paolo
    Martin, Gerard R.
    Sanchez Luna, Manuel
    Mestrovic, Julije
    Simeoni, Umberto
    Zimmermann, Luc
    Ewer, Andrew K.
    LANCET CHILD & ADOLESCENT HEALTH, 2017, 1 (02): : 88 - 90