Preparation and Electrochemical Behavior of L-Glutamate Electrochemical Biosensor

被引:253
|
作者
Deng, Yan [1 ,2 ]
Wang, Wei [1 ]
Zhang, Liming [1 ,2 ]
Lu, Zhuoxuan [1 ,2 ]
Li, Song [1 ]
Xu, Lijian [1 ]
机构
[1] Hunan Univ Technol, Hunan Key Lab Green Packaging & Applicat Biol Nan, Zhuzhou 412007, Peoples R China
[2] Southeast Univ, State Key Lab Bioelect, Nanjing 210096, Jiangsu, Peoples R China
关键词
L-Glutamate; Biosensor; Electrochemical; Nano-Porous Pseudo Carbon Paste Electrode; CARBON NANOTUBES; MAGNETIC NANOPARTICLES; MASS-SPECTROMETRY; ACID; OXIDASE; SYSTEM; CANCER; ZNO;
D O I
10.1166/jbn.2013.1487
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Using the nano-porous pseudo carbon paste electrode (Nano-PPCPE) as the working electrode, mixing L-glutamate oxidase (L-GLOD), catalase (Cat) and bovine serum albumin (BSA) with phosphate buffer (PB, pH = 7.4), followed by cross-linking with glutaraldehyde, a novel L-glutamate electrochemical biosensor was successfully formed. It was demonstrated that the modified nano-PPCPE exhibits a high selectivity and sensitivity in comparison with the modified CPE. The L-glutamate biosensor showed a linear range from 5 x 10(-7) M to 1 x 10(-5) M with the detection limit of 2.5 x 10(-7) M.
引用
收藏
页码:318 / 321
页数:4
相关论文
共 50 条
  • [41] AUTOMATED MEASUREMENT OF L-GLUTAMATE IN SOY SAUCE USING L-GLUTAMATE DEHYDROGENASE
    KIKUCHI, M
    OZAWA, Y
    SUZUKI, K
    AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1973, 37 (07): : 1673 - 1677
  • [42] Rapid and simple preparation of a reagentless glucose electrochemical biosensor
    Zheng, Dan
    Vashist, Sandeep Kumar
    Al-Rubeaan, Khalid
    Luong, John H. T.
    Sheu, Fwu-Shan
    ANALYST, 2012, 137 (16) : 3800 - 3805
  • [43] Electrochemical properties of violuric acid and oxidase biosensor preparation
    Krikstopaitis, K
    Kulys, J
    ELECTROCHEMISTRY COMMUNICATIONS, 2000, 2 (02) : 119 - 123
  • [44] Electrochemical preparation and electrical characterization of polyaniline as a sensitive biosensor
    Hamida H. Hamid
    Mohamed E. Harb
    A. M. Elshaer
    Sh. Erahim
    Moataz M. Soliman
    Microsystem Technologies, 2018, 24 : 1775 - 1781
  • [45] Electrochemical preparation and electrical characterization of polyaniline as a sensitive biosensor
    Hamid, Hamida H.
    Harb, Mohamed E.
    Elshaer, A. M.
    Erahim, Sh.
    Soliman, Moataz M.
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2018, 24 (04): : 1775 - 1781
  • [46] In Vivo Detection of Glutamate in Tomatoes by an Enzyme-Based Electrochemical Biosensor
    Tang, Shunkun
    Wang, Cheng
    Liu, Ke
    Luo, Bin
    Dong, Hongtu
    Wang, Xiaodong
    Hou, Peichen
    Li, Aixue
    ACS OMEGA, 2022, 7 (34): : 30535 - 30542
  • [47] Graphene and tricobalt tetraoxide nanoparticles based biosensor for electrochemical glutamate sensing
    Dalkiran, Berna
    Erden, Pinar Esra
    Kilic, Esma
    ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2017, 45 (02) : 340 - 348
  • [48] STUDIES ON L-GLUTAMATE IN INSECT HEMOLYMPH .1. EFFECT OF INJECTED L-GLUTAMATE
    IRVING, SN
    OSBORNE, MP
    WILSON, RG
    PHYSIOLOGICAL ENTOMOLOGY, 1979, 4 (02) : 139 - 146
  • [49] Optical biosensor test strip for the screening and direct determination of L-glutamate in food samples
    Muslim, Noor Zuhartini Md
    Ahmad, Musa
    Heng, Lee Yook
    Saad, Bahruddin
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 493 - 497
  • [50] Enzyme-based choline and L-glutamate biosensor electrodes on silicon microprobe arrays
    Frey, O.
    Holtzman, T.
    McNamara, R. M.
    Theobald, D. E. H.
    van der Wal, P. D.
    de Rooij, N. F.
    Dalley, J. W.
    Koudelka-Hep, M.
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (02): : 477 - 484