Preparation and Electrochemical Behavior of L-Glutamate Electrochemical Biosensor

被引:253
|
作者
Deng, Yan [1 ,2 ]
Wang, Wei [1 ]
Zhang, Liming [1 ,2 ]
Lu, Zhuoxuan [1 ,2 ]
Li, Song [1 ]
Xu, Lijian [1 ]
机构
[1] Hunan Univ Technol, Hunan Key Lab Green Packaging & Applicat Biol Nan, Zhuzhou 412007, Peoples R China
[2] Southeast Univ, State Key Lab Bioelect, Nanjing 210096, Jiangsu, Peoples R China
关键词
L-Glutamate; Biosensor; Electrochemical; Nano-Porous Pseudo Carbon Paste Electrode; CARBON NANOTUBES; MAGNETIC NANOPARTICLES; MASS-SPECTROMETRY; ACID; OXIDASE; SYSTEM; CANCER; ZNO;
D O I
10.1166/jbn.2013.1487
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Using the nano-porous pseudo carbon paste electrode (Nano-PPCPE) as the working electrode, mixing L-glutamate oxidase (L-GLOD), catalase (Cat) and bovine serum albumin (BSA) with phosphate buffer (PB, pH = 7.4), followed by cross-linking with glutaraldehyde, a novel L-glutamate electrochemical biosensor was successfully formed. It was demonstrated that the modified nano-PPCPE exhibits a high selectivity and sensitivity in comparison with the modified CPE. The L-glutamate biosensor showed a linear range from 5 x 10(-7) M to 1 x 10(-5) M with the detection limit of 2.5 x 10(-7) M.
引用
收藏
页码:318 / 321
页数:4
相关论文
共 50 条
  • [1] Fabrication of an Electrochemical Biosensor Array for Simultaneous Detection of L-Glutamate and Acetylcholine
    Deng, Yan
    Wang, Wei
    Ma, Chao
    Li, Zhiyang
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2013, 9 (08) : 1378 - 1382
  • [2] Detection of L-glutamate using a nano-porous pseudo carbon paste electrode electrochemical biosensor
    Deng, Yan
    Wang, Wei
    He, Nongyue
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [3] Electrochemical Study of Ion Channel Behavior in Incorporated Poly L-glutamate Bilayer Lipid Membranes
    Yuehong Tong
    Zhengyan Wu
    Xiaojun Han
    Erkang Wang
    Journal of Bioenergetics and Biomembranes, 2002, 34 : 185 - 191
  • [4] Electrochemical study of ion channel behavior in incorporated poly L-glutamate bilayer lipid membranes
    Tong, YH
    Wu, ZY
    Han, XJ
    Wang, EK
    JOURNAL OF BIOENERGETICS AND BIOMEMBRANES, 2002, 34 (03) : 185 - 191
  • [5] Characterization of a thermophilic L-glutamate dehydrogenase biosensor for amperometric determination of L-glutamate by flow injection analysis
    Pasco, N.
    Jeffries, C.
    Davies, Q.
    Downard, A.J.
    Roddick-Lanzilotta, A.D.
    Gorton, L.
    Biosensors and Bioelectronics, 1999, 14 (02): : 171 - 178
  • [6] Characterisation of a thermophilic L-glutamate dehydrogenase biosensor for amperometric determination of L-glutamate by flow injection analysis
    Pasco, N
    Jeffries, C
    Davies, Q
    Downard, AJ
    Roddick-Lanzilotta, AD
    Gorton, L
    BIOSENSORS & BIOELECTRONICS, 1999, 14 (02): : 171 - 178
  • [7] A biosensor based on co-immobilized L-glutamate oxidase and L-glutamate dehydrogenase for analysis of monosodium glutamate in food
    Basu, AK
    Chattopadhyay, P
    Roychudhuri, U
    Chakraborty, R
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (10): : 1968 - 1972
  • [8] EFFECT OF L-GLUTAMATE ON THE RELEASE OF STRIATAL DOPAMINE - INVIVO DIALYSIS AND ELECTROCHEMICAL STUDIES
    MOGHADDAM, B
    GRUEN, RJ
    ROTH, RH
    BUNNEY, BS
    ADAMS, RN
    BRAIN RESEARCH, 1990, 518 (1-2) : 55 - 60
  • [9] A peptide aptamer based electrochemical amperometric sensor for sensitive L-glutamate detection
    Wang, Wenjing
    He, Yumin
    Gao, Yunling
    Gao, Hongrui
    Deng, Lei
    Gui, Qingwen
    Cao, Zhong
    Yin, Yulong
    Feng, Zemeng
    BIOELECTROCHEMISTRY, 2022, 146
  • [10] l-Glutamate biosensor for estimation of the taste of tomato specimens
    Rasa Pauliukaite
    Gleb Zhylyak
    Daniel Citterio
    Ursula E. Spichiger-Keller
    Analytical and Bioanalytical Chemistry, 2006, 386 : 220 - 227