A front-end electronic system for large arrays of bolometers

被引:44
|
作者
Arnaboldi, C. [1 ,2 ]
Carniti, P. [1 ,2 ]
Cassina, L. [1 ,2 ]
Gotti, C. [1 ,2 ]
Liu, X. [3 ]
Maino, M. [1 ,2 ]
Pessina, G. [1 ,2 ]
Rosenfeld, C. [3 ]
Zhu, B. X. [4 ]
机构
[1] Ist Nazl Fis Nucl, Sez Milano Bicocca, Piazza Sci 3, I-20126 Milan, Italy
[2] Univ Milano Bicocca, Dipartimento Fis G Occhialini, Piazza Sci 3, I-20126 Milan, Italy
[3] Univ South Carolina, Dept Phys & Astron, Columbia, SC 29208 USA
[4] Univ Calif Los Angeles, Dept Phys & Astron, 475 Portola Plaza, Los Angeles, CA 90095 USA
来源
基金
欧洲研究理事会;
关键词
Analogue electronic circuits; Front-end electronics for detector readout; Modular electronics; Detector control systems (detector and experiment monitoring and slow-control systems; architecture; hardware; algorithms databases); DOUBLE-BETA-DECAY; LARGE-MASS BOLOMETERS; LOW-FREQUENCY; THERMAL DETECTORS; RARE DECAYS; CUORE; NOISE; SPECTROSCOPY; STABILITY; DESIGN;
D O I
10.1088/1748-0221/13/02/P02026
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
CUORE is an array of thermal calorimeters composed of 988 crystals held at about 10 mK, whose absorbed energy is read out with semiconductor thermistors. The composition of the crystal is TeO2, and the aim is the study of the double beta decay of Te-130 on very long and stable runs. CUPID-0 is an array of 26 (ZnSe)-Se-82 crystals with double thermistor readout to study the double beta decay of Se-82. In the present paper, we present an overview of the entire front-end electronic readout chain, from the preamplifier to the anti-aliasing filter. This overview includes motivations, design strategies, circuit implementation and performance results of the electronic system, including other auxiliary yet important elements like power supplies and the slow control communication system. The stringent requirements of stability on the very long experimental runs that are foreseen during CUORE and CUPID-0 operation, are achieved thanks to novel solutions of the front-end preamplifier and of the detector bias circuit setup.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] Multichannel monolithic front-end system design - 4. Front-end system stability and channel-to-channel coupling
    Belarussian State Univ, Minsk, Belarus
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 398 (2-3): : 308 - 314
  • [32] Design of front-end electronic circuits for dedicated PET detectors
    Zhang, N
    Thompson, CJ
    Togane, D
    Cayouette, F
    Nguyen, KQ
    Camborde, ML
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1984 - 1987
  • [33] FRONT-END PROCESSORS
    STIEFEL, ML
    MINI-MICRO SYSTEMS, 1977, 10 (10): : 58 - &
  • [34] Front-end thinkers
    Carreira Zafra, Cintia
    BORDON-REVISTA DE PEDAGOGIA, 2020, 72 (03): : 176 - 178
  • [35] FRONT-END ALIGNMENT
    FELDMAN, L
    AUDIO, 1969, 53 (05): : 30 - &
  • [36] Parallelism in the front-end
    Oberoi, PS
    Sohi, GS
    30TH ANNUAL INTERNATIONAL SYMPOSIUM ON COMPUTER ARCHITECTURE, PROCEEDINGS, 2003, : 230 - 240
  • [37] Miniaturized Rx front-end modules for digital beam forming arrays
    Goron, E
    Coupez, JP
    Person, C
    Toutain, Y
    Lattard, H
    Perrot, F
    2005 IEEE MTT-S International Microwave Symposium, Vols 1-4, 2005, : 2255 - 2258
  • [38] Front-end adaptive electronic modeling with neural networks for radioastronomy
    Censier, B.
    Bosse, S.
    2020 XXXIIIRD GENERAL ASSEMBLY AND SCIENTIFIC SYMPOSIUM OF THE INTERNATIONAL UNION OF RADIO SCIENCE, 2020,
  • [39] 'FRONT-END LOADER'
    SALOM, P
    WESTERLY, 1988, 33 (02): : 101 - 101
  • [40] Front-end Loder
    Lamb, Andrew
    OPERA, 2013, 64 (03): : 306 - 306