A front-end electronic system for large arrays of bolometers

被引:44
|
作者
Arnaboldi, C. [1 ,2 ]
Carniti, P. [1 ,2 ]
Cassina, L. [1 ,2 ]
Gotti, C. [1 ,2 ]
Liu, X. [3 ]
Maino, M. [1 ,2 ]
Pessina, G. [1 ,2 ]
Rosenfeld, C. [3 ]
Zhu, B. X. [4 ]
机构
[1] Ist Nazl Fis Nucl, Sez Milano Bicocca, Piazza Sci 3, I-20126 Milan, Italy
[2] Univ Milano Bicocca, Dipartimento Fis G Occhialini, Piazza Sci 3, I-20126 Milan, Italy
[3] Univ South Carolina, Dept Phys & Astron, Columbia, SC 29208 USA
[4] Univ Calif Los Angeles, Dept Phys & Astron, 475 Portola Plaza, Los Angeles, CA 90095 USA
来源
基金
欧洲研究理事会;
关键词
Analogue electronic circuits; Front-end electronics for detector readout; Modular electronics; Detector control systems (detector and experiment monitoring and slow-control systems; architecture; hardware; algorithms databases); DOUBLE-BETA-DECAY; LARGE-MASS BOLOMETERS; LOW-FREQUENCY; THERMAL DETECTORS; RARE DECAYS; CUORE; NOISE; SPECTROSCOPY; STABILITY; DESIGN;
D O I
10.1088/1748-0221/13/02/P02026
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
CUORE is an array of thermal calorimeters composed of 988 crystals held at about 10 mK, whose absorbed energy is read out with semiconductor thermistors. The composition of the crystal is TeO2, and the aim is the study of the double beta decay of Te-130 on very long and stable runs. CUPID-0 is an array of 26 (ZnSe)-Se-82 crystals with double thermistor readout to study the double beta decay of Se-82. In the present paper, we present an overview of the entire front-end electronic readout chain, from the preamplifier to the anti-aliasing filter. This overview includes motivations, design strategies, circuit implementation and performance results of the electronic system, including other auxiliary yet important elements like power supplies and the slow control communication system. The stringent requirements of stability on the very long experimental runs that are foreseen during CUORE and CUPID-0 operation, are achieved thanks to novel solutions of the front-end preamplifier and of the detector bias circuit setup.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] A programmable front-end system for arrays of bolometers
    Alessandrello, A
    Brofferio, C
    Bucci, C
    Cremonesi, O
    Giuliani, A
    Nucciotti, A
    Pavan, M
    Perego, M
    Pessina, G
    Pirro, S
    Previtali, E
    Vanzini, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2): : 111 - 114
  • [2] The programmable front-end readout system for Cuoricino, an array of large mass bolometers
    Arnboldi, C
    Bucci, C
    Campbell, JW
    Nucciotti, A
    Pavan, M
    Pessina, G
    Pirro, S
    Previtali, E
    Rosenfeld, C
    Sisti, M
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 773 - 777
  • [3] The programmable front-end system for CUORICINO, an array of large-mass bolometers
    Arnaboldi, C
    Bucci, C
    Campbell, JW
    Capelli, S
    Nucciotti, A
    Pavan, M
    Pessina, G
    Pirro, S
    Previtali, E
    Rosenfeld, C
    Sisti, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2440 - 2447
  • [4] Front-end electronic system for large area photomultipliers readout
    Bottino, B.
    Caminata, A.
    Cariello, M.
    Cresta, M.
    Davini, S.
    Musico, P.
    Pallavicini, M.
    Testera, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 325 - 326
  • [5] A front-end for an array of μ-bolometers for the study of the neutrino mass
    Alessandrello, A
    Brofferio, C
    Cremonesi, O
    Giuliani, A
    Pedretti, M
    Nucciotti, A
    Pavan, M
    Pessina, G
    Previtali, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (06) : 1851 - 1856
  • [6] A front-end for an array of μ-bolometers for the study of the neutrino mass
    Alessandrello, A
    Brofferio, C
    Cremonesi, O
    Giuliani, A
    Monfardini, A
    Nucciotti, A
    Pavan, M
    Pessina, G
    Previtali, E
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 390 - 395
  • [7] The front-end readout for CUORICINO, an array of macro-bolometers and MIBETA, an array of μ-bolometers
    Arnaboldi, C
    Bucci, C
    Capelli, S
    Fascilla, A
    Gorla, P
    Nucciotti, A
    Pedretti, M
    Pessina, G
    Pirro, S
    Previtali, E
    Sisti, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 578 - 580
  • [8] THE FRONT-END SYSTEM
    CHAPPELL, SG
    HENIG, FH
    WATSON, DS
    BELL SYSTEM TECHNICAL JOURNAL, 1982, 61 (06): : 1165 - 1176
  • [9] Electronic stability of silicon front-end hybrids
    Peek, HZ
    Peeters, UM
    PROCEEDINGS OF THE EIGHTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 2002, 2002 (03): : 400 - 403
  • [10] Front-end Control Mechanism of Electronic Records
    Xu, Jiang
    Wang, Ling
    Liu, Xinyu
    Feng, Xiujuan
    Ren, Yongjun
    Xia, Jinyue
    COMPUTER SYSTEMS SCIENCE AND ENGINEERING, 2021, 39 (03): : 337 - 349