Comparison of laterally condensed .06 and .02 tapered gutta-percha and sealer in vitro
被引:23
|
作者:
Bal, AS
论文数: 0引用数: 0
h-index: 0
机构:
Albert Einstein Med Ctr, IB Bender Div Endodont, Philadelphia, PA 19141 USAAlbert Einstein Med Ctr, IB Bender Div Endodont, Philadelphia, PA 19141 USA
Bal, AS
[1
]
Hicks, ML
论文数: 0引用数: 0
h-index: 0
机构:
Albert Einstein Med Ctr, IB Bender Div Endodont, Philadelphia, PA 19141 USAAlbert Einstein Med Ctr, IB Bender Div Endodont, Philadelphia, PA 19141 USA
Hicks, ML
[1
]
Barnett, F
论文数: 0引用数: 0
h-index: 0
机构:
Albert Einstein Med Ctr, IB Bender Div Endodont, Philadelphia, PA 19141 USAAlbert Einstein Med Ctr, IB Bender Div Endodont, Philadelphia, PA 19141 USA
Barnett, F
[1
]
机构:
[1] Albert Einstein Med Ctr, IB Bender Div Endodont, Philadelphia, PA 19141 USA
The purpose of this in vitro study was to compare the quality of the seal in canals prepared in a standardized manner and obturated with a .06 or a .02 tapered gutta-percha master cone using lateral condensation. Forty-four extracted human anterior teeth with single, straight canals were divided into two experimental groups of 20 teeth each and two control groups of 2 teeth each. The teeth were instrumented with Series 29 Profile .06 tapered rotary nickel-titanium files to a master apical file of 0.46 mm. Teeth in group 1 were obturated with a .02 tapered master gutta-percha cone and Roth 801 sealer using lateral condensation. Teeth in group 2 were obturated similarly, except a .06 tapered master gutta-percha cone was used. The depth of spreader penetration was recorded in millimeters. Positive control teeth were instrumented but not filled. Negative control teeth were instrumented, obturated, and externally sealed. The teeth were placed into a coronal leakage apparatus that contained an upper and lower reservoir of trypticase soy broth separated by the tooth. A 24-h growth of Proteus vulgaris in 0.25 ml of trypticase soy broth was placed in the coronal reservoir every 7 days for 70 days and incubated at 37 degreesC. Student's t test was used to determine whether there was a difference in spreader penetration between the groups, and a Fisher's exact test was used to determine whether there was a difference in bacterial leakage. The positive and negative controls validated the testing model. When a .02 tapered master cone was used, the spreader penetrated significantly closer to working length than when a .06 tapered master cone was used (p < 0.05). The difference between the groups in the number of samples that demonstrated complete bacterial penetration was not significant (p > 0.05).
机构:
Univ Illinois, Vet Med Teaching Hosp 174, Dept Vet Clin Med, Urbana, IL 61802 USAUniv Illinois, Vet Med Teaching Hosp 174, Dept Vet Clin Med, Urbana, IL 61802 USA
Stein, KE
Marretta, SM
论文数: 0引用数: 0
h-index: 0
机构:
Univ Illinois, Vet Med Teaching Hosp 174, Dept Vet Clin Med, Urbana, IL 61802 USAUniv Illinois, Vet Med Teaching Hosp 174, Dept Vet Clin Med, Urbana, IL 61802 USA
Marretta, SM
Siegel, A
论文数: 0引用数: 0
h-index: 0
机构:
Univ Illinois, Vet Med Teaching Hosp 174, Dept Vet Clin Med, Urbana, IL 61802 USAUniv Illinois, Vet Med Teaching Hosp 174, Dept Vet Clin Med, Urbana, IL 61802 USA
Siegel, A
Vitoux, J
论文数: 0引用数: 0
h-index: 0
机构:
Univ Illinois, Vet Med Teaching Hosp 174, Dept Vet Clin Med, Urbana, IL 61802 USAUniv Illinois, Vet Med Teaching Hosp 174, Dept Vet Clin Med, Urbana, IL 61802 USA