CO2 stripping from ionic liquid at elevated pressures in gas-liquid membrane contactor

被引:30
|
作者
Bazhenov, Stepan [1 ]
Malakhov, Alexander [1 ]
Bakhtin, Danila [1 ]
Khotimskiy, Valery [1 ]
Bondarenko, Galina [1 ]
Volkov, Vladimir [1 ]
Ramdin, Mahinder [2 ]
Vlugt, Thijs J. H. [2 ]
Volkov, Alexey [1 ]
机构
[1] AV Topchiev Inst Petrochem Synth RAS, Leninsky Prospect 29, Moscow 119991, Russia
[2] Delft Univ Technol, Proc & Energy Dept, Leeghwaterstr 39, NL-2628 CB Delft, Netherlands
关键词
Membrane contactor; Room-temperature ionic liquid; PTMSP; Carbon dioxide; Stripping; CARBON-DIOXIDE CAPTURE; OF-THE-ART; ABSORPTION PROCESS; REGENERATION; SOLUBILITY; MONOETHANOLAMINE; POLYMER; PERMEABILITY; SELECTIVITY; PERMEATION;
D O I
10.1016/j.ijggc.2018.03.001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, the gas-liquid membrane contactor was considered for regeneration of the room-temperature ionic liquids (RTIL) that can be used as physical solvents for carbon dioxide capture process at elevated pressures. Poly [1-(trimethylsilyl)-1-propyne] (PTMSP) was selected as a membrane material due to its high mass transport characteristics and good mechanical properties. Nine different RTILs, such as [Emim][DCA], [Emim][BF4], [Emim][DEP], [Bmim][BF4], [Bmim][Tf2N], [Hmim][TCB], [P66614][DCA], [P66614][Br] and [P66614] [Phos], were used to evaluate the solvent-membrane compatibility. The long-term sorption tests (40+ days) revealed that the solvent-membrane interaction is mainly determined by the liquid surface tension regardless of viscosity and molecular size of RTILs. For instance, [Emim][BF4] and [Emim][DCA], having the surface tension of 60.3 and 54.0 mN/m, demonstrated a very low affinity to the bulk material of PTMSP (sorption as low as 0.02 g/g; no swelling); while for the next ionic liquid [Bmim][BF4] with surface tension of 44.4 mN/m, the sorption and swelling of PTMSP was 0.79 g/g and 21%, respectively. The long-term RTIL permeation test (Delta p=40 bar, T=50 degrees C, t > 400 h) confirmed that there is no hydrodynamic flow through PTMSP for [Emim] [DCA] and [Emim][BF4]. The concept of CO2 stripping from RTIL with the membrane contactor by the pressure (Delta p=10 bar) and temperature (Delta T=20 degrees C) swing was proved by using dense PTMSP membrane and [Emim] [BF4]. The overall mass transfer coefficient value was equal to (1.6-3.8) x10(-3) cm/s with respect to liquid flow rate. By using the resistance-in-series model, it was shown that the membrane resistance contribution to the gas transfer was estimated to be approximately 8%.
引用
收藏
页码:293 / 302
页数:10
相关论文
共 50 条
  • [21] CO2 absorption property of ionic liquid and CO2 permselectivity for ionic liquid membrane
    National Institute of Advanced Industrial Science and Technology, 4-2-1 Nigatake, Miyagino-ku
    Sendai
    983-8551, Japan
    [J]. J. Jpn. Pet. Inst., 4 (109-117):
  • [22] CO2 Absorption Property of Ionic Liquid and CO2 Permselectivity for Ionic Liquid Membrane
    Makino, Takashi
    Kanakubo, Mitsuhiro
    [J]. JOURNAL OF THE JAPAN PETROLEUM INSTITUTE, 2016, 59 (04) : 109 - 117
  • [23] CFD investigation of CO2 separation from anesthesia gaseous stream applying novel cholinium lysinate amino acid-based ionic liquid inside the gas-liquid membrane contactor
    Cao, Yan
    Nakhjiri, Ali Taghvaie
    Ghadiri, Mahdi
    [J]. EUROPEAN PHYSICAL JOURNAL PLUS, 2022, 137 (09):
  • [24] Biogas upgrading by CO2 removal with a highly selective natural amino acid salt in gas-liquid membrane contactor
    Yan, Shuiping
    He, Qingyao
    Zhao, Shuaifei
    Wang, Yuanyuan
    Ai, Ping
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2014, 85 : 125 - 135
  • [25] Pushing the limits of intensified CO2 post-combustion capture by gas-liquid absorption through a membrane contactor
    Chabanon, E.
    Bounaceur, R.
    Castel, C.
    Rode, S.
    Roizard, D.
    Favre, E.
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2015, 91 : 7 - 22
  • [26] Surface modification of polypropylene hollow fiber membranes using fluorosilane for CO2 absorption in a gas-liquid membrane contactor
    Kim, Kwanghwi
    Lee, Heejun
    Park, Hyun Sic
    Song, Hojun
    Kim, Suhan
    [J]. HELIYON, 2023, 9 (09)
  • [27] An electrolytic bubble column with an external hollow fiber membrane gas-liquid contactor for effective microbial electrosynthesis of acetate from CO2
    Cui, Kai
    Guo, Kun
    Carvajal-Arroyo, Jose M.
    Arends, Jan
    Rabaey, Korneel
    [J]. CHEMICAL ENGINEERING JOURNAL, 2023, 471
  • [28] CO2 absorption at elevated pressures using a hollow fiber membrane contactor
    Dindore, VY
    Brilman, DWF
    Feron, PHM
    Versteeg, GF
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2004, 235 (1-2) : 99 - 109
  • [29] Improved CO2 Absorption in a Gas-Liquid Countercurrent Column Using a Ceramic Foam Contactor
    Wang, Zhen
    Gupta, Mayank
    Warudkar, Sumedh S.
    Cox, Kenneth R.
    Hirasaki, George J.
    Wong, Michael S.
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2016, 55 (05) : 1387 - 1400
  • [30] Development of robust fluorinated TiO2/PVDF composite hollow fiber membrane for CO2 capture in gas-liquid membrane contactor
    Lin, Yuqing
    Xu, Yilin
    Loh, Chun Heng
    Wang, Rong
    [J]. APPLIED SURFACE SCIENCE, 2018, 436 : 670 - 681