Estimation of radiation exposure in low-dose multislice computed tomography of the heart and comparison with a calculation program

被引:36
|
作者
Hohl, C.
Muehlenbruch, G.
Wildberger, J. E.
Leidecker, C.
Suss, C.
Schmidt, T.
Guenther, R. W.
Mahnken, A. H.
机构
[1] Univ Technol Aachen, Dept Diagnost Radiol, D-52057 Aachen, Germany
[2] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
[3] Siemens Med Solut Comp Tomog, D-91301 Forchheim, Germany
关键词
dose reduction; MSCT; low-kV scan protocol; calculation program; cardiac;
D O I
10.1007/s00330-005-0124-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the achievable organ dose savings in low-dose multislice computed tomography (MSCT) of the heart using different tube voltages (80 kVp, 100 kVp, 120 kVp) and compare it with calculated values. A female Alderson-Rando phantom was equipped with thermoluminescent dosimeters (TLDs) in five different positions to assess the mean doses within representative organs (thyroid gland, thymus, oesophagus, pancreas, liver). Radiation exposure was performed on a 16-row MSCT scanner with six different routine scan protocols: a 120-kV and a 100-kV CT angiography (CTA) protocol with the same collimation, two 120-kV Ca-scoring (CS) protocols with different collimations and two 80-kV CS protocols with the same collimation as the 120-kV CS protocols. Each scan protocol was repeated five times. The measured dose values for the organs were compared with the values calculated by a commercially available computer program. Directly irradiated organs, such as the esophagus, received doses of 34.7 mSv (CTA 16x0.75 120 kVp), 21.9 mSv (CTA 16x0.75 100 kVp) and 4.96 mSv (CS score 12x1.5 80 kVp), the thyroid as an organ receiving only scattered radiation collected organ doses of 2.98 mSv (CTA 16x0.75 120 kVp), 1.97 mSv (CTA 16x0.75 100 kVp) and 0.58 mSv (CS score 12x1.5 80 kVp). The measured relative organ dose reductions from standard to low-kV protocols ranged from 30.9% to 55.9% and were statistically significant (P < 0.05). The comparison with the calculated organ doses showed that the calculation program can predict the relative dose reduction of cardiac low photon-energy protocols precisely.
引用
收藏
页码:1841 / 1846
页数:6
相关论文
共 50 条
  • [1] Estimation of radiation exposure in low-dose multislice computed tomography of the heart and comparison with a calculation program
    C. Hohl
    G. Mühlenbruch
    J. E. Wildberger
    C. Leidecker
    C. Süß
    T. Schmidt
    R. W. Günther
    A. H. Mahnken
    [J]. European Radiology, 2006, 16 : 1841 - 1846
  • [2] Cone beam computed tomography and low-dose multislice computed tomography in orthodontics and dentistry A comparative evaluation on image quality and radiation exposure
    Hofmann, Elisabeth
    Schmid, Matthias
    Lell, Michael
    Hirschfelder, Ursula
    [J]. JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2014, 75 (05): : 384 - 398
  • [3] Radiation dose exposure in multislice computed tomography of the coronaries in comparison with conventional coronary angiography
    Dill, Thorsten
    Deetjen, Anja
    Ekinci, Okan
    Moellmann, Susanne
    Conradi, Guido
    Kluge, Alexander
    Weber, Christoph
    Weber, Michael
    Nef, Holger
    Hamm, Christian W.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 124 (03) : 307 - 311
  • [4] Multislice computed tomography of the coronaries: intraindividual comparison of radiation dose exposure with conventional coronary angiography
    Deetjen, A.
    Moellmann, S.
    Conradi, G.
    Ekinci, O.
    Hansel, J.
    Kluge, A.
    Hamm, C. W.
    Dill, T.
    [J]. EUROPEAN HEART JOURNAL, 2005, 26 : 437 - 437
  • [5] Intraindividual comparison of radiation dose exposure between multislice computed tomography and conventional coronary angiography
    Möllmann, S
    Deetjen, A
    Conradi, G
    Weber, M
    Hamm, CW
    Dill, T
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 128A - 128A
  • [6] Low-Dose Computed Tomography for the Optimization of Radiation Dose Exposure in Patients with Crohn's Disease
    Kavanagh, Richard G.
    O'Grady, John
    Carey, Brian W.
    McLaughlin, Patrick D.
    O'Neill, Siobhan B.
    Maher, Michael M.
    O'Connor, Owen J.
    [J]. GASTROENTEROLOGY RESEARCH AND PRACTICE, 2018, 2018
  • [7] Comparative study of image quality and radiation dose of cone beam and low-dose multislice computed tomography - an in-vitro investigation
    Hofmann, Elisabeth
    Schmid, Matthias
    Sedlmair, Martin
    Banckwitz, Rosemarie
    Hirschfelder, Ursula
    Lell, Michael
    [J]. CLINICAL ORAL INVESTIGATIONS, 2014, 18 (01) : 301 - 311
  • [8] Comparative study of image quality and radiation dose of cone beam and low-dose multislice computed tomography - an in-vitro investigation
    Elisabeth Hofmann
    Matthias Schmid
    Martin Sedlmair
    Rosemarie Banckwitz
    Ursula Hirschfelder
    Michael Lell
    [J]. Clinical Oral Investigations, 2014, 18 : 301 - 311
  • [9] Low-dose multislice spiral computed tomography in acute lung injury -: Animal experience
    Wildberger, JE
    Max, M
    Wein, BB
    Mahnken, AH
    Weiss, C
    Dembinski, R
    Katoh, M
    Schaller, S
    Rossaint, R
    Günther, RW
    [J]. INVESTIGATIVE RADIOLOGY, 2003, 38 (01) : 9 - 16
  • [10] Radiation Exposure to Low-Dose Computed Tomography for Lung Cancer Screening: Should We Be Concerned?
    Pozzessere, Chiara
    von Garnier, Christophe
    Beigelman-Aubry, Catherine
    [J]. TOMOGRAPHY, 2023, 9 (01) : 166 - 177