A validated enantioselective LC-MS/MS assay for the simultaneous determination of carvedilol and its pharmacologically active 4′-hydroxyphenyl metabolite in human plasma: Application to a clinical pharmacokinetic study

被引:26
|
作者
Furlong, Michael T. [1 ]
He, Bing [2 ]
Mylott, William [3 ]
Zhao, Song [3 ]
Mariannino, Thomas [3 ]
Shen, Jim [1 ]
Stouffer, Bruce [1 ]
机构
[1] Bristol Myers Squibb Co, Res & Dev, Analyt & Bioanalyt Dev, Princeton, NJ 08543 USA
[2] Bristol Myers Squibb Co, Res & Dev, Discovery Med & Clin Pharmacol, Princeton, NJ 08543 USA
[3] PPD, Res & Dev, Richmond, VA 23230 USA
关键词
Carvedilol; Metabolite; LC-MS/MS; Assay; Enantiomer; Derivatization; PERFORMANCE LIQUID-CHROMATOGRAPHY; HEART-FAILURE PATIENTS; STEREOSELECTIVE DISPOSITION; CHIRAL DERIVATIZATION; ENANTIOMERS; CYP2D6;
D O I
10.1016/j.jpba.2012.05.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carvedilol is widely prescribed for the treatment of hypertension, heart failure and left ventricular dysfunction following myocardial infarction. A sensitive and reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed and validated to enable reliable and efficient bioanalysis of the (R)- and (S)-enantiomers of carvedilol and its pharmacologically active 4'-hydroxyphenyl metabolite in human plasma. Following plasma extraction using supported liquid extraction (SLE) in a 96-well plate format, extracted samples were derivatized with 2,3,4,6-tetra-O-acetyl-beta-D-glucopyranosyl isothiocyanate (GITC). Chromatographic separation was achieved by gradient elution on an ACQUITY UPLC MSS T3 analytical column. The impact of several potentially interfering isobaric metabolites on the quantification of the 4'-hydroxyphenyl metabolite (R)- and (S)-enantiomers was minimized by implementation of a combination of chromatographic and mass spectrometric techniques. Derivatized analytes and stable-labeled internal standards were detected by positive ion electrospray tandem mass spectrometry. The assay was validated over concentration ranges of 0.200-100 ng/mL for (R)- and (S)-carvedilol and 0.0200-10.0 ng/mL for (R)- and (S)-4'-hydroxyphenyl carvedilol. Intra- and inter-assay precision values for replicate quality control samples were within 11.9% for all analytes during the assay validation. Mean quality control accuracy values were within +/-9.4% of nominal values for all analytes. Assay recoveries were high (>76%) and internal standard normalized matrix effects were minimal. The four analytes were stable in human plasma for at least 24h at room temperature, 89 days at -20 degrees C and -70 degrees C, and following at least five freeze-thaw cycles. The validated assay was successfully applied to the quantification of the (R)- and (S)-enantiomers of both carvedilol and its pharmacologically active 4'-hydroxyphenyl metabolite in human plasma in support of a human pharmacokinetic study. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:574 / 579
页数:6
相关论文
共 50 条
  • [41] Determination of lacosamide in human plasma by LC-MS/MS and its application to a human pharmacokinetic study
    Yadlapalli, Siva Sankara Rao
    Katari, Naresh Kumar
    Surya, Surendra Babu Manabolu
    SEPARATION SCIENCE PLUS, 2020, 3 (06): : 216 - 224
  • [42] Simultaneous determination and determination of sildenafil and its active metabolite in human plasma using LC-MS/MS method
    Li, Lin-ling
    Zhang, Xiu-jin
    Zheng, Chao
    Fan, Ming-xia
    Xu, Hao-yun
    Yi, Jin-ling
    Feng, Yan
    Luo, Xi
    Li, Wei-hua
    Cheng, Ze-neng
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (10)
  • [43] Simultaneous determination of simvastatin, lovastatin and niacin in human plasma by LC-MS/MS and its application to a human pharmacokinetic study
    Pilli, Nageswara Rao
    Mullangi, Ramesh
    Inamadugu, Jaswanth Kuamr
    Nallapati, Indira Kumari
    Rao, J. V. L. N. Seshagiri
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (04) : 476 - 484
  • [44] Simultaneous determination of atorvastatin, metformin and glimepiride in human plasma by LC-MS/MS and its application to a human pharmacokinetic study
    Polagani, Srinivasa Rao
    Pilli, Nageswara Rao
    Gajula, Ramakrishna
    Gandu, Venkateswarlu
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2013, 3 (01) : 9 - 19
  • [45] Simultaneous determination of atorvastatin,metformin and glimepiride in human plasma by LC-MS/MS and its application to a human pharmacokinetic study
    Srinivasa Rao Polagani
    Nageswara Rao Pilli
    Ramakrishna Gajula
    Venkateswarlu Gandu
    JournalofPharmaceuticalAnalysis, 2013, 3 (01) : 9 - 19
  • [46] A Rapid and Sensitive LC-MS/MS Assay for the Determination of Saxagliptin and its Active Metabolite 5-hydroxy Saxagliptin in Human Plasma and its Application to a Pharmacokinetic Study
    Batta, N.
    Pilli, N. R.
    Derangula, V. R.
    Vurimindi, H. B.
    Damaramadugu, R.
    Yejella, R. P.
    DRUG RESEARCH, 2015, 65 (03) : 133 - 140
  • [47] A simple LC-MS/MS method for pharmacokinetic study of carvedilol and 4/-hydroxyphenyl carvedilol at a low dose
    Eiamart, Wanna
    Prompila, Nantaporn
    Jumroen, Yaowatree
    Sayankuldilok, Nonlanee
    Chariyavilaskul, Pajaree
    Wittayalertpanya, Supeecha
    RESEARCH IN PHARMACEUTICAL SCIENCES, 2022, 17 (03) : 231 - 241
  • [48] Validated LC-MS/MS method for quantification of agomelatine in human plasma and its application in a pharmacokinetic study
    Patil, Satish R.
    Nerurkar, Ketan K.
    Kalamkar, Ashok M.
    Pukale, Vishwas
    Mangaonkar, Kiran V.
    Pingale, Satish G.
    JOURNAL OF MASS SPECTROMETRY, 2012, 47 (01): : 23 - 28
  • [49] Simultaneous quantification of naproxcinod and its active metabolite naproxen in rat plasma using LC-MS/MS: Application to a pharmacokinetic study
    Shi, Xiaowei
    Shang, Weiding
    Wang, Shuang
    Xue, Na
    Hao, Yanxia
    Wang, Yabo
    Sun, Mengmeng
    Du, Yumin
    Cao, Deying
    Zhang, Kai
    Shi, Qingwen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 978 : 157 - 162
  • [50] Simultaneous Determination of Carvedilol, Enalaprilat, and Perindoprilat in Human Plasma Using LC–MS/MS and Its Application to a Pharmacokinetic Pilot Study
    Andre Joubert
    Tracy Kellermann
    Anton Joubert
    Marthinus van der Merwe
    Jennifer Norman
    Sandra Castel
    Karen Sliwa
    Gary Maartens
    Phumla Sinxadi
    Lubbe Wiesner
    Chromatographia, 2022, 85 : 455 - 468