Beam delivery system tuning and luminosity monitoring in the Compact Linear Collider

被引:12
|
作者
Dalena, B. [1 ]
Barranco, J. [1 ]
Latina, A. [1 ]
Marin, E. [1 ]
Pfingstner, J. [1 ]
Schulte, D. [1 ]
Snuverink, J. [1 ]
Tomas, R. [1 ]
Zamudio, G. [1 ]
机构
[1] CERN, Geneva, Switzerland
关键词
D O I
10.1103/PhysRevSTAB.15.051006
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
Emittance preservation in the beam delivery system (BDS) is one of the major challenges in the Compact Linear Collider (CLIC). The fast detuning of the final focus optics requires an on-line tuning procedure in order to keep luminosity close to the maximum. In this paper we discuss different tuning techniques to mitigate the displacement of magnets in the CLIC BDS and in particular in the final focus system. Some of them require a fast luminosity measurement. Here we study the possibility to use beam-beam background processes at CLIC 3 TeV c.m. energy as a fast luminosity signal. In particular, the hadron multiplicity in the detector region is investigated.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Electron beam deceleration measurements using the decelerator test beam line in the Compact Linear Collider test facility
    Lillestol, R. L.
    Doebert, S.
    Adli, E.
    Olvegard, M.
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2014, 17 (03):
  • [42] Simulations of the static tuning for the TESLA linear collider
    Schulte, D
    Walker, N
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 2736 - 2738
  • [43] Automatic luminosity optimization of the ILC head-on beam delivery system
    Payet, J.
    Chance, A.
    Napoly, O.
    Uriot, D.
    Auclair, S.
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 3776 - +
  • [44] Beam Position and Energy Monitoring in Compact Linear Accelerators for Radiotherapy
    Ruf, Marcel
    Mueller, Sven
    Setzer, Stefan
    Schmidt, Lorenz-Peter
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (02) : 381 - 387
  • [45] Compact source and beam delivery system for EUV radiation
    Mann, Klaus
    Barkusky, Frank
    Bayer, Armin
    Peth, Christian
    Toettger, Holger
    EMERGING LITHOGRAPHIC TECHNOLOGIES X, PTS 1 AND 2, 2006, 6151 : U575 - U586
  • [46] Physics with an e+e- linear collider at high luminosity
    Zerwas, PM
    PARTICLE PHYSICS: IDEAS AND RECENT DEVELOPMENTS, 2000, 555 : 65 - 93
  • [47] A statistical method for luminosity monitoring in high energy collider experiments
    Bastos, J.
    Carvalho, J.
    Schmelling, M.
    JOURNAL OF INSTRUMENTATION, 2006, 1
  • [48] The impact of synchrotron radiation at the Compact Linear Collider
    Arominski, D.
    Sailer, A.
    Latina, A.
    Schulte, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 983
  • [49] Static beam-based alignment for the Ring-To-Main- Linac of the Compact Linear Collider
    Han, Y.
    Latina, A.
    Ma, L.
    Schulte, D.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [50] Low emittance design of the electron gun and the focusing channel of the Compact Linear Collider drive beam
    Kelisani, M. Dayyani
    Doebert, S.
    Aslaninejad, M.
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2017, 20 (04):