共 25 条
Partition efficiencies of newly fabricated universal high-speed counter-current chromatograph for separation of two different types of sugar derivatives with organic-aqueous two-phase solvent systems
被引:15
|作者:
Shinomiya, Kazufusa
[1
]
Sato, Kazuki
[1
]
Yoshida, Kazunori
[2
]
Tokura, Koji
[2
]
Maruyama, Hiroshi
[2
]
Yanagidaira, Kazuhiro
[2
]
Ito, Yoichiro
[3
]
机构:
[1] Nihon Univ, Sch Pharm, Funabashi, Chiba 2748555, Japan
[2] Nihon Univ, Coll Sci & Technol, Funabashi, Chiba 2748501, Japan
[3] NHLBI, Lab Bioseparat Technol, Biochem & Biophys Ctr, NIH, Bethesda, MD 20892 USA
关键词:
Counter-current chromatography;
Instrumentation;
Sugar derivatives;
COIL PLANET CENTRIFUGE;
POLYMER PHASE SYSTEMS;
COLUMN;
PURIFICATION;
PERFORMANCE;
PROTEINS;
D O I:
10.1016/j.chroma.2013.10.096
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
A new design of universal high-speed counter-current chromatograph (HSCCC) was fabricated in our laboratory. It holds a set of four column holders symmetrically around the rotary frame at a distance of 11.2 cm from the central axis. By engaging the stationary gear on the central axis of the centrifuge to the planetary gears on the column holder shaft through a set of idle gears, two pairs of diagonally located column holders simultaneously rotate about their own axes in the opposite directions: one forward (type-J planetary motion) and the other backward (type-I planetary motion) each synchronously with the revolution. Using the eccentric coil assembly, partition efficiencies produced by these two planetary motions were compared on the separation of two different types of sugar derivatives (4-methylumbelliferyl and 5-bromo-4-chloro-3-indoxyl sugar derivatives) using organic-aqueous two-phase solvent systems composed of n-hexane/ethyl acetate/1-butanol/methanollwater and aqueous 0.1 M sodium tetraborate, respectively. With lower phase mobile, better peak resolution was obtained by the type-J forward rotation for both samples probably due to higher retention of the stationary phase. With upper phase mobile, however, similar peak resolutions were obtained between these two planetary motions for both sugar derivatives. The overall results indicate that the present universal HSCCC is useful for counter-current chromatographic separation since each planetary motion has its specific applications: e.g., vortex CCC by the type-I planetary motion and HSCCC by the type-J planetary motion both for separation of various natural and synthetic products. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:74 / 80
页数:7
相关论文