Partition efficiencies of newly fabricated universal high-speed counter-current chromatograph for separation of two different types of sugar derivatives with organic-aqueous two-phase solvent systems

被引:15
|
作者
Shinomiya, Kazufusa [1 ]
Sato, Kazuki [1 ]
Yoshida, Kazunori [2 ]
Tokura, Koji [2 ]
Maruyama, Hiroshi [2 ]
Yanagidaira, Kazuhiro [2 ]
Ito, Yoichiro [3 ]
机构
[1] Nihon Univ, Sch Pharm, Funabashi, Chiba 2748555, Japan
[2] Nihon Univ, Coll Sci & Technol, Funabashi, Chiba 2748501, Japan
[3] NHLBI, Lab Bioseparat Technol, Biochem & Biophys Ctr, NIH, Bethesda, MD 20892 USA
关键词
Counter-current chromatography; Instrumentation; Sugar derivatives; COIL PLANET CENTRIFUGE; POLYMER PHASE SYSTEMS; COLUMN; PURIFICATION; PERFORMANCE; PROTEINS;
D O I
10.1016/j.chroma.2013.10.096
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new design of universal high-speed counter-current chromatograph (HSCCC) was fabricated in our laboratory. It holds a set of four column holders symmetrically around the rotary frame at a distance of 11.2 cm from the central axis. By engaging the stationary gear on the central axis of the centrifuge to the planetary gears on the column holder shaft through a set of idle gears, two pairs of diagonally located column holders simultaneously rotate about their own axes in the opposite directions: one forward (type-J planetary motion) and the other backward (type-I planetary motion) each synchronously with the revolution. Using the eccentric coil assembly, partition efficiencies produced by these two planetary motions were compared on the separation of two different types of sugar derivatives (4-methylumbelliferyl and 5-bromo-4-chloro-3-indoxyl sugar derivatives) using organic-aqueous two-phase solvent systems composed of n-hexane/ethyl acetate/1-butanol/methanollwater and aqueous 0.1 M sodium tetraborate, respectively. With lower phase mobile, better peak resolution was obtained by the type-J forward rotation for both samples probably due to higher retention of the stationary phase. With upper phase mobile, however, similar peak resolutions were obtained between these two planetary motions for both sugar derivatives. The overall results indicate that the present universal HSCCC is useful for counter-current chromatographic separation since each planetary motion has its specific applications: e.g., vortex CCC by the type-I planetary motion and HSCCC by the type-J planetary motion both for separation of various natural and synthetic products. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 25 条
  • [1] Separation of Proteins in Aqueous Two-Phase Systems with High-Speed Counter-Current Chromatography
    Zhi Wenbo
    Deng Qiuyun
    Song Jiangnan
    Gu Ming
    Ouyang Fan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (01) : 12 - 17
  • [2] Versatile two-phase solvent system for alkaloid separation by high-speed counter-current chromatography
    Yuan, LM
    Zi, M
    Ai, P
    Chen, XX
    Li, ZY
    Fu, RN
    Zhang, TY
    JOURNAL OF CHROMATOGRAPHY A, 2001, 927 (1-2) : 91 - 96
  • [3] Design of a coil satellite centrifuge and its performance on counter-current chromatographic separation of 4-methylumbelliferyl sugar derivatives with polar organic-aqueous two-phase solvent systems
    Shinomiya, Kazufusa
    Tokura, Koji
    Kimura, Emiru
    Takai, Midori
    Harikai, Naoki
    Yoshida, Kazunori
    Yanagidaira, Kazuhiro
    Ito, Yoichiro
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1392 : 48 - 55
  • [4] Organic high ionic strength aqueous two-phase solvent system series for separation of ultra-polar compounds by spiral high-speed counter-current chromatography
    Zeng, Yun
    Liu, Gang
    Ma, Ying
    Chen, Xiaoyuan
    Ito, Yoichiro
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (48) : 8715 - 8717
  • [5] Effect of inorganic salt on partition of high-polarity parishins in two-phase solvent systems and separation by high-speed counter-current chromatography from Gastrodia elata Blume
    Dong, Hongjing
    Yao, Xue
    Liu, Dahui
    Zhou, Tao
    Wu, Guozhen
    Zheng, Xiuhua
    Wang, Xiao
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (04) : 871 - 877
  • [6] Countercurrent chromatographic separation of biotic compounds with extremely hydrophilic organic-aqueous two-phase solvent systems and organic-aqueous three-phase solvent systems
    Shinomiya, K
    Ito, Y
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (05) : 733 - 750
  • [7] Separation of nucleobases and their derivatives with organic-high ionic strength aqueous phase systems by spiral high-speed counter-current chromatography
    Shibusawa, Yoichi
    Yanagida, Akio
    Ogihara, Atsushi
    Ma, Ying
    Chen, Xiaoyuan
    Ito, Yoichiro
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 891 : 94 - 97
  • [8] Study of the applicability of non-conventional aqueous two-phase systems in counter-current and centrifugal partition chromatography
    Bezold, Franziska
    Goll, Johannes
    Minceva, Mirjana
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1388 : 126 - 132
  • [9] Hydrophilic organic/salt-containing aqueous two-phase solvent system for counter-current chromatography: A novel technique for separation of polar compounds
    Liu, Dan
    Zou, Xiaowei
    Gao, Mingzhe
    Gu, Ming
    Xiao, Hongbin
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1356 : 157 - 162
  • [10] Modeling and optimization of two phase system for recycling high-speed counter-current chromatographic separation of ketoconazole enantiomers
    Zhang, Panliang
    Xie, Na
    Tang, Kewen
    Chen, Xiaoming
    Xu, Weifeng
    SEPARATION AND PURIFICATION TECHNOLOGY, 2016, 164 : 41 - 48