High intense positron beam at the new Munich research reactor FRM-II

被引:10
|
作者
Hugenschmidt, C
Kögel, G
Schreckenbach, K
Sperr, P
Springer, M
Strasser, B
Triftshäuser, W
机构
[1] Tech Univ Munich, Projektgrp FRM 2, Reaktorstn, D-85747 Garching, Germany
[2] Univ Bundeswehr Munchen, Inst Nukl Festkorperphys, D-85577 Neubiberg, Germany
关键词
intense source; positron beam; neutron capture; pair production; research reactor;
D O I
10.1016/S0169-4332(99)00163-4
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The Munich Intense POsitron Source (MIPOS) facility for producing a high intense positron beam at the new Munich research reactor (Forschungs-Reaktor Munchen II) FRM-II is presented. Positrons are generated by pair production of high energy prompt gamma-rays from neutron capture in cadmium: Cd-113(n,gamma)Cd-114. A cadmium cap will be located inside a beamtube at an undisturbed thermal neutron flux of 2 x 10(14) n cm(-2) s(-1). Model calculation showed that this would lead to a mean capture rate of 1.7 x 10(13) n cm(-2) s(-1). Thermal load resulting from absorbed gamma-rays is expected to be less than 4 W cm(-2). Inside the cadmium cap a structure of platinum and a stack of tungsten foils is placed for converting the gamma-rays into positron-electron pairs. Platinum is used as converting material, since the cross section for pair production is even higher (+11%) than in tungsten. The maximum of the energy spectrum of the positrons produced is about 800 keV. The tungsten foils also act as moderator. The positrons will be accelerated by electric lenses and guided by magnetic fields. Various arrangements are tested to improve the efficiency of the system. After remoderation of the positron beam an intensity of about 10(9) slow positrons per second is expected. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:7 / 10
页数:4
相关论文
共 50 条
  • [41] The new single crystal diffractometer RESI at FRM-II
    Pedersen, Bjorn
    Frey, Friedrich
    Scherer, Wolfgang
    Gille, Peter
    Meisterernst, Goetz
    PHYSICA B-CONDENSED MATTER, 2006, 385-86 (1046-1048) : 1046 - 1048
  • [42] The new structure powder diffractometer at the FRM-II in Garching
    Gilles, R
    Artus, G
    Saroun, J
    Boysen, H
    Fuess, H
    PHYSICA B, 2000, 276 : 87 - 88
  • [43] Concept of the new thermal single crystal diffractometer at FRM-II
    Artus, GRJ
    Gilles, R
    Frey, F
    Scherer, W
    PHYSICA B, 2000, 276 : 77 - 78
  • [44] Comparison Radiography and Tomography Possibilities of FRM-II (20 MW) and Budapest (10 MW) Research Reactor
    Balasko, M.
    Kuba, A.
    Tanacs, A.
    Kiss, Z.
    Nagy, A.
    Schillinger, B.
    NEUTRON RADIOGRAPHY, 2008, : 18 - +
  • [45] Germany's Garching FRM-II high-flux neutron research reactor goes into operation for the first time.
    不详
    NUCLEAR ENERGY-JOURNAL OF THE BRITISH NUCLEAR ENERGY SOCIETY, 2004, 43 (03): : 130 - 130
  • [46] Design of the triple-axis spectrometer PANDA at the high-flux reactor FRM-II of Garching
    Loewenhaupt, M
    Pyka, NM
    PHYSICA B-CONDENSED MATTER, 1999, 267 : 336 - 340
  • [47] The ultrahigh flux polarized cold neutron spectrometer PANDA of the FRM-II reactor
    Loewenhaupt, M
    Pyka, NM
    JOURNAL OF APPLIED PHYSICS, 1999, 85 (08) : 5145 - 5147
  • [49] Optimization of a partially non-magnetic primary radiation shielding for the triple-axis spectrometer PANDA at the Munich high-flux reactor FRM-II
    Pyka, NM
    Noack, K
    Rogov, A
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2002, 74 (Suppl 1): : S277 - S279
  • [50] The new Single Crystal Diffractometer HEiDi at the FRM-II and its Applications
    Meven, Martin
    Hutanu, Vladimir
    Heger, Gernot