Clinical pilot study of different hand positions during manual chest compressions monitored with capnography

被引:62
|
作者
Qvigstad, Eric [1 ,2 ]
Kramer-Johansen, Jo [1 ,2 ,3 ]
Tomte, Oystein [4 ]
Skalhegg, Tore [5 ]
Sorensen, Oyvar [5 ]
Sunde, Kjetil [2 ,3 ]
Olasveengen, Theresa M. [1 ,2 ,3 ]
机构
[1] Oslo Univ Hosp, Expt Med Res Inst, Pb 4956 Nydalen, N-0424 Oslo, Norway
[2] Univ Oslo, N-0424 Oslo, Norway
[3] Oslo Univ Hosp, Dept Anesthesiol, N-0424 Oslo, Norway
[4] Drammen Hosp, Dept Anesthesiol, N-3004 Drammen, Norway
[5] Oslo Univ Hosp, Ambulance Dept, N-0424 Oslo, Norway
关键词
Cardiac arrest; Advanced life support; Capnography; Carbon dioxide; Chest compressions; TIDAL CARBON-DIOXIDE; RESUSCITATION-COUNCIL GUIDELINES; HEART-ASSOCIATION GUIDELINES; BASIC LIFE-SUPPORT; CARDIOPULMONARY-RESUSCITATION; CARDIAC-ARREST; PRESSURE; EPINEPHRINE; CPR;
D O I
10.1016/j.resuscitation.2013.03.010
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose of the study: Optimal hand position for chest compressions during cardiopulmonary resuscitation is unknown. Recent imaging studies indicate significant inter-individual anatomical variations, which might cause varying haemodynamic responses with standard chest compressions. This prospective clinical pilot study intended to assess the feasibility of utilizing capnography to optimize chest compressions and identify the optimal hand position. Materials and methods: Intubated cardiac arrest patients treated by the physician manned ambulance between February and December 2011 monitored with continuous end-tidal CO2 (EtCO2) measurements were included. One minute of chest compressions at the inter-nipple line (INL) optimized using EtCO2 feedback, was followed by four 30-s intervals with compressions at four different sites; INL, 2 cm below the INL, 2 cm below and to the left of INL and 2 cm below and to the right of INL. Results: Thirty patients were included. At the end of each 30-s interval median (range) EtCO2 was 3.1 kPa (0.7-8.7 kPa) at INL, 3.5 kPa (0.5-10.7) 2 cm below INL, 3.5 kPa (0.5-10.3 kPa) 2 cm below and to the left of INL, and 3.8 kPa (0.4-8.8 kPa) 2 cm below and to the right of INL (p = 0.4). The EtCO2 difference within each subject between hand positions with maximum and minimum values varied between individuals from 0.2 to 3.4 kPa (median 0.9 kPa). Conclusion: Monitoring and optimizing chest compressions using capnography was feasible. We could not demonstrate one superior hand position, but inter-individual differences suggest optimal hand position might vary significantly among patients. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1203 / 1207
页数:5
相关论文
共 50 条
  • [31] Expert clinical assessment of thorax stiffness of infants and children during chest compressions
    Arbogast, Kristy B.
    Nishisaki, Akira
    Balasubramanian, Sriram
    Nysaether, Jon
    Niles, Dana
    Sutton, Robert M.
    Roberts, Kathryn E.
    Nadkarni, Lauren
    Boulet, John
    Maltese, Matthew R.
    Nadkarni, Vinay M.
    RESUSCITATION, 2009, 80 (10) : 1187 - 1191
  • [32] Expert clinical assessment of thorax stiffness of infants and children during chest compressions
    Arbogast, Kristy
    Niles, Dana
    Nishisaki, Akira
    Sutton, Robert
    Roberts, Kathryn E.
    Nadkarni, Lauren
    Maltese, Matthew
    Balasubramanian, Sriram
    Nadkarni, Vinay M.
    Nysaether, Jon
    CRITICAL CARE MEDICINE, 2007, 35 (12) : A102 - A102
  • [33] Effectiveness of chest compressions after a short training method: a pilot study with future lifeguards
    Ruibal-Lista, Brais
    Hernandez-Gil, Katlyn Marcela
    Palacios-Aguilar, Jose
    Lopez-Garcia, Sergio
    SIGNA VITAE, 2021, 17 (04) : 151 - 156
  • [34] Comparison of effects of different hand positions during cardiopulmonary resuscitation
    Diószeghy, C
    Kiss, D
    Fritúz, G
    Székely, G
    Élo, G
    RESUSCITATION, 2005, 66 (03) : 297 - 301
  • [35] Force distribution across the heel of the hand during simulated manual chest compression
    Baubin, M
    Kollmitzer, J
    Pomaroli, A
    Kraincuk, P
    Kranzl, A
    Sumann, G
    Wiesinger, GF
    Gilly, H
    RESUSCITATION, 1997, 35 (03) : 259 - 263
  • [36] SUPERIOR MYOCARDIAL PERFUSION WITH OPEN CHEST CARDIAC MASSAGE VERSUS RAPID MANUAL EXTERNAL CHEST COMPRESSIONS DURING PROLONGED CARDIOPULMONARY RESUSCITATION
    KERN, KB
    SANDERS, AB
    NELSON, J
    EWY, GA
    CLINICAL RESEARCH, 1990, 38 (02): : A340 - A340
  • [37] ECG Rhythm Analysis During Manual Chest Compressions Using an Artefact Removal Filter and Random Forest Classifiers
    Isasi, Iraia
    Rad, Ali Bahrami
    Irusta, Unai
    Zabihi, Morteza
    Aramendi, Elisabete
    Eftestol, Trygve
    Kramer-Johansen, Jo
    Wik, Lars
    2018 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2018, 45
  • [38] Mountain rescue cardiopulmonary resuscitation: a comparison between manual and mechanical chest compressions during manikin cardio resuscitation
    Thomassen, Oyvind
    Skaiaa, Sven Christjar
    Assmuss, Jorg
    Osteras, Oyvind
    Heltne, Jon Kenneth
    Wik, Lars
    Brattebo, Guttorm
    EMERGENCY MEDICINE JOURNAL, 2017, 34 (09) : 573 - 577
  • [39] Comparison between manual and mechanical chest compressions during resuscitation in a pediatric animal model of asphyxial cardiac arrest
    Lopez, Jorge
    Fernandez, Sarah N.
    Gonzalez, Rafael
    Solana, Maria A. J.
    Urbano, Javier
    Toledo, Blanca
    Lopez-Herce, Jesus
    PLOS ONE, 2017, 12 (11):
  • [40] Does the use of a chest compression system in children improve the effectiveness of chest compressions? A randomised crossover simulation pilot study
    Szarpak, Lukasz
    Truszewski, Zenon
    Smereka, Jacek
    Czyzewski, Lukasz
    KARDIOLOGIA POLSKA, 2016, 74 (12) : 1499 - 1504