Clinical pilot study of different hand positions during manual chest compressions monitored with capnography

被引:62
|
作者
Qvigstad, Eric [1 ,2 ]
Kramer-Johansen, Jo [1 ,2 ,3 ]
Tomte, Oystein [4 ]
Skalhegg, Tore [5 ]
Sorensen, Oyvar [5 ]
Sunde, Kjetil [2 ,3 ]
Olasveengen, Theresa M. [1 ,2 ,3 ]
机构
[1] Oslo Univ Hosp, Expt Med Res Inst, Pb 4956 Nydalen, N-0424 Oslo, Norway
[2] Univ Oslo, N-0424 Oslo, Norway
[3] Oslo Univ Hosp, Dept Anesthesiol, N-0424 Oslo, Norway
[4] Drammen Hosp, Dept Anesthesiol, N-3004 Drammen, Norway
[5] Oslo Univ Hosp, Ambulance Dept, N-0424 Oslo, Norway
关键词
Cardiac arrest; Advanced life support; Capnography; Carbon dioxide; Chest compressions; TIDAL CARBON-DIOXIDE; RESUSCITATION-COUNCIL GUIDELINES; HEART-ASSOCIATION GUIDELINES; BASIC LIFE-SUPPORT; CARDIOPULMONARY-RESUSCITATION; CARDIAC-ARREST; PRESSURE; EPINEPHRINE; CPR;
D O I
10.1016/j.resuscitation.2013.03.010
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose of the study: Optimal hand position for chest compressions during cardiopulmonary resuscitation is unknown. Recent imaging studies indicate significant inter-individual anatomical variations, which might cause varying haemodynamic responses with standard chest compressions. This prospective clinical pilot study intended to assess the feasibility of utilizing capnography to optimize chest compressions and identify the optimal hand position. Materials and methods: Intubated cardiac arrest patients treated by the physician manned ambulance between February and December 2011 monitored with continuous end-tidal CO2 (EtCO2) measurements were included. One minute of chest compressions at the inter-nipple line (INL) optimized using EtCO2 feedback, was followed by four 30-s intervals with compressions at four different sites; INL, 2 cm below the INL, 2 cm below and to the left of INL and 2 cm below and to the right of INL. Results: Thirty patients were included. At the end of each 30-s interval median (range) EtCO2 was 3.1 kPa (0.7-8.7 kPa) at INL, 3.5 kPa (0.5-10.7) 2 cm below INL, 3.5 kPa (0.5-10.3 kPa) 2 cm below and to the left of INL, and 3.8 kPa (0.4-8.8 kPa) 2 cm below and to the right of INL (p = 0.4). The EtCO2 difference within each subject between hand positions with maximum and minimum values varied between individuals from 0.2 to 3.4 kPa (median 0.9 kPa). Conclusion: Monitoring and optimizing chest compressions using capnography was feasible. We could not demonstrate one superior hand position, but inter-individual differences suggest optimal hand position might vary significantly among patients. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1203 / 1207
页数:5
相关论文
共 50 条
  • [1] Changing Hand Position During Manual Chest Compressions in Cardiac Arrest Affects the Hemodynamic Response: A Clinical Pilot Study
    Qvigstad, Eric
    Tomte, Oystein
    Sunde, Kjetil
    Skalhegg, Tore
    Sorensen, Oyvard
    Kramer-Johansen, Jo
    Olasveengen, Theresa Mariero
    CIRCULATION, 2011, 124 (21)
  • [2] Assessment of the Quality of Manual Chest Compressions and Rescuer Fatigue in Different Cardiopulmonary Resuscitation Positions
    Li, Beibei
    Zhang, Pan
    Xu, Shuang
    Liu, Qian
    Ma, Yannan
    Zhou, Siyi
    Xu, Li
    Sun, Peng
    PREHOSPITAL AND DISASTER MEDICINE, 2024, 39 (06) : 415 - 420
  • [3] Hand placement during chest compressions in parturients: a pilot study to identify the location of the left ventricle using transthoracic echocardiography
    Delgado, C.
    Dawson, K.
    Schwaegler, B.
    Zachariah, R.
    Einav, S.
    Bollag, L.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2020, 43 : 31 - 35
  • [4] Early survival after cardiac arrest in a pilot study using the LUCAS device compared to manual chest compressions during CPR
    Rubertsson, Sten
    Huzevka, Tibor
    Smelkal, David
    Johansson, Jakob
    CIRCULATION, 2007, 116 (16) : 386 - 386
  • [5] Comparison of Effects of Different Hand Positions During Chest Compression: A Randomized, Controlled, Crossover Mannequin Study
    Fei, Han
    ANESTHESIA AND ANALGESIA, 2024, 139 (06):
  • [6] Three Methods of Manual External Chest Compressions During Microgravity Simulation
    Rehnberg, Lucas
    Ashcroft, Alexandra
    Baers, Justin H.
    Campos, Fabio
    Cardoso, Ricardo B.
    Velho, Rochelle
    Gehrke, Rodrigo D.
    Dias, Mariana K. P.
    Baptista, Rafael R.
    Russomano, Thais
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2014, 85 (07): : 687 - 693
  • [7] A Method to Evaluate the Quality of Chest Compressions During Manual Cardiopulmonary Resuscitation
    Sun, Mingze
    Pan, Chang
    Pang, Jiaojiao
    Wang, Jiali
    Li, Ke
    Xu, Feng
    Chen, Yuguo
    2022 INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS AND MECHATRONICS (ICARM 2022), 2022, : 325 - 330
  • [8] Chest Compressions During Cardiopulmonary Resuscitation Produce Oscillations in Capnography Associated With Return of Spontaneous Circulation
    Bhandari, S.
    Coult, J.
    Counts, C.
    Kwok, H.
    Sayre, M.
    Rea, T.
    Johnson, N.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [9] Effectiveness of mechanical versus manual chest compressions in out-of-hospital cardiac arrest resuscitation: A pilot study
    Dickinson, ET
    Verdile, VP
    Schneider, RM
    Salluzzo, RF
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1998, 16 (03): : 289 - 292
  • [10] No difference in autopsy detected injuries in cardiac arrest patients treated with manual chest compressions compared with mechanical compressions with the LUCAS™ device-A pilot study
    Smekal, David
    Johansson, Jakob
    Huzevka, Tibor
    Rubertsson, Sten