REAL-TIME MONITORING OF HIGH-INTENSITY FOCUSED ULTRASOUND TREATMENT USING AXIAL STRAIN AND AXIAL-SHEAR STRAIN ELASTOGRAMS

被引:14
|
作者
Xia, Rongmin [1 ]
Thittai, Arun K. [1 ]
机构
[1] Univ Texas Houston, Sch Med, Dept Diagnost & Intervent Imaging, Ultrason Lab, Houston, TX 77030 USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2014年 / 40卷 / 03期
关键词
Axial strain; Axial- shear strain; Cavitation bubbles; Elastography; High-intensity focused ultrasound; Multiple lesions; Real time; Single lesion; Strain; Stress; Treatment monitoring; Ultrasound; HIFU-INDUCED LESIONS; INDUCED ECHO-STRAIN; IN-VIVO; THERMAL LESIONS; TISSUE; VISUALIZATION; FEASIBILITY; ABLATION; SURGERY; FIELDS;
D O I
10.1016/j.ultrasmedbio.2013.10.006
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Axial strain elastograms (ASEs) have been found to help visualize sonographically invisible thermal lesions. However, in most studies involving high-intensity focused ultrasound (HIFU)-induced thermal lesions, elastography imaging was performed separately later, after the lesion was formed. In this article, the feasibility of monitoring, in real time, tissue elasticity variation during HIFU treatment and immediately thereafter is explored using quasi-static elastography. Further, in addition to ASEs, we also explore the use of simultaneously acquired axial-shear strain elastograms (ASSEs) for HIFU lesion visualization. Experiments were performed on commercial porcine liver samples in vitro. The HIFU experiments were conducted at two applied acoustic power settings, 35 and 20 W. The experimental setup allowed us to interrupt the HIFU pulse momentarily several different times during treatment to perform elastographic compression and data acquisition. At the end of the experiments, the samples were cut along the imaging plane and photographed to compare size and location of the formed lesion with those visualized on ASEs and ASSEs. Single-lesion and multiple-lesion experiments were performed to assess the contribution of ASEs and ASSEs to lesion visualization and treatment monitoring tasks. At both power settings, ASEs and ASSEs provided accurate location information during HIFU treatment. At the low-power setting case, ASEs and ASSEs provide accurate lesion size in real-time monitoring. Lesion appearance in ASEs and ASSEs was affected by the cavitation bubbles produced at the high-power setting. The results further indicate that the cavitation bubbles influence lesion appearance more in ASEs than in ASSEs. Both ASEs and ASSEs provided accurate size information after a waiting period that allowed the cavitation bubbles to disappear. The results indicate that ASSEs not only improve lesion visualization and size measurement of a single lesion, but, under certain conditions, also help to identify untreated gaps between adjacent lesions with high contrast. (C) 2014 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:485 / 495
页数:11
相关论文
共 50 条
  • [1] Detection of gaps between high-intensity focused ultrasound (HIFU)-induced lesions using transient axial shear strain elastograms
    Liu, Chenhui
    Zhou, Yufeng
    [J]. MEDICAL PHYSICS, 2018, 45 (08) : 3831 - 3847
  • [2] Importance of Axial Compression Verification to Correct Interpretation of Axial-Shear Strain Elastograms in Breast Lesions
    Thittai, Arun K.
    Galaz, Belfor
    Ophir, Jonathan
    [J]. ULTRASONIC IMAGING, 2010, 32 (03) : 190 - 198
  • [3] Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging
    Vaezy, S
    Shi, XG
    Martin, RW
    Chi, E
    Nelson, PI
    Bailey, MR
    Crum, LA
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (01): : 33 - 42
  • [4] Fluorescence imaging for real-time monitoring of high-intensity focused ultrasound cardiac ablation
    Deng, CRX
    Qu, FJ
    Nikolski, VP
    Zhou, Y
    Efimov, IR
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (10) : 1352 - 1359
  • [5] Fluorescence Imaging for Real-Time Monitoring of High-Intensity Focused Ultrasound Cardiac Ablation
    Cheri X. Deng
    Fujian Qu
    Vladimir P. Nikolski
    Yun Zhou
    Igor R. Efimov
    [J]. Annals of Biomedical Engineering, 2005, 33 : 1352 - 1359
  • [6] REAL-TIME MONITORING OF HIGH-INTENSITY FOCUSED ULTRASOUND THERMAL THERAPY USING THE MANIFOLD LEARNING METHOD
    Rangraz, Parisa
    Behnam, Hamid
    Sobhebidari, Pooya
    Tavakkoli, Jahan
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (12): : 2841 - 2850
  • [7] IMPORTANCE OF THE ULTRASOUND PROBE ANGLE ON THE ROTATION FILL-IN SIGNATURE IN ULTRASOUND AXIAL-SHEAR STRAIN IMAGING
    Galaz, Belfor
    Donoso, Esteban
    Trejo, Miguel
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (02): : 345 - 354
  • [8] Real-time monitoring of high-intensity focused ultrasound ablations with photoacoustic technique: An in vitro study
    Cui, Huizhong
    Yang, Xinmai
    [J]. MEDICAL PHYSICS, 2011, 38 (10) : 5345 - 5350
  • [9] REAL-TIME MONITORING OF HIGH-INTENSITY FOCUSED ULTRASOUND LESION FORMATION USING ACOUSTO-OPTIC SENSING
    Lai, Puxiang
    McLaughlan, James R.
    Draudt, Andrew B.
    Murray, Todd W.
    Cleveland, Robin O.
    Roy, Ronald A.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (02): : 239 - 252
  • [10] In Vivo Classification of Breast Masses Using Features Derived From Axial-Strain and Axial-Shear Images
    Xu, Haiyan
    Varghese, Tomy
    Jiang, Jingfeng
    Zagzebski, James A.
    [J]. ULTRASONIC IMAGING, 2012, 34 (04) : 222 - 236