Amperometric determination of inositol based on electrocatalytic oxidation on a glass carbon electrode modified by nickel hexacyanoferrate films

被引:9
|
作者
Yang, YH [1 ]
Zhao, QR
Wang, ZJ
Yang, MH
机构
[1] Yunnan Normal Univ, Coll Chem & Chem Engn, Kunming 650092, Peoples R China
[2] Hunan Univ, State Key Lab Chemobiosensing & Chemometr, Changsha, Peoples R China
关键词
amperometric; inositol; electrocatalytic oxidation; nickel hexacyanoferrate;
D O I
10.1080/00032710500477118
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method to determinate inositol based on the electrocatalytic oxidation of inositol on the surface of a nickel hexacyanoferrate (NiHCF)-modified electrode was reported. The determination of inositol can be performed in the range of 1.0 x 10(-4) to 5.8 x 10(-3) mol/L with a detection limit of 5.0 x 10(-5) mol/L.
引用
收藏
页码:361 / 372
页数:12
相关论文
共 50 条
  • [41] Electrocatalytic oxidation of hydrazine at a chromium hexacyanoferrate/single-walled carbon nanotube modified glassy carbon electrode
    Fang, Bin
    Shen, Rongxing
    Zhang, Wei
    Wang, Guangfeng
    Zhang, Cuihong
    MICROCHIMICA ACTA, 2009, 165 (1-2) : 231 - 236
  • [42] Electrocatalytic oxidation of hydrazine at the poly(glutamic acid) chemically modified electrode and its amperometric determination
    Yu, AM
    Chen, HY
    ANALYTICAL LETTERS, 1997, 30 (03) : 599 - 607
  • [43] Electrocatalytic oxidation of hydrazine at a chromium hexacyanoferrate/single-walled carbon nanotube modified glassy carbon electrode
    Bin Fang
    Rongxing Shen
    Wei Zhang
    Guangfeng Wang
    Cuihong Zhang
    Microchimica Acta, 2009, 165 : 231 - 236
  • [44] Evaluation of a mechanically immobilized nickel hexacyanoferrate electrode as an amperometric sensor for thiosulfate determination
    Shankaran, DR
    Narayanan, SS
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (08): : 663 - 665
  • [45] Evaluation of a mechanically immobilized nickel hexacyanoferrate electrode as an amperometric sensor for thiosulfate determination
    D. R. Shankaran
    S. S. Narayanan
    Fresenius' Journal of Analytical Chemistry, 1999, 365 : 663 - 665
  • [46] Amperometric determination of L-dopa by nickel hexacyanoferrate film modified gold nanoparticle graphite composite electrode
    Prabhu, P.
    Babu, R. Suresh
    Narayanan, S. Sriman
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 156 (02): : 606 - 614
  • [47] Amperometric determination of hydrazine using a surface modified nickel hexacyanoferrate graphite electrode fabricated following a new approach
    Prabakar, S. J. Richard
    Narayanan, S. Sriman
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 617 (02) : 111 - 120
  • [48] Amperometric nonenzymatic determination of glucose based on a glassy carbon electrode modified with nickel(II) oxides and graphene
    Xiaohua Zhu
    Qifang Jiao
    Chuyi Zhang
    Xiaoxi Zuo
    Xin Xiao
    Yong Liang
    Junmin Nan
    Microchimica Acta, 2013, 180 : 477 - 483
  • [49] Electrocatalytic oxidation of captopril using a carbon-paste electrode modified with copper-cobalt hexacyanoferrate
    Jalali, Fahimeh
    Ranjbar, Sedigheh
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (05) : 482 - 489
  • [50] Amperometric nonenzymatic determination of glucose based on a glassy carbon electrode modified with nickel(II) oxides and graphene
    Zhu, Xiaohua
    Jiao, Qifang
    Zhang, Chuyi
    Zuo, Xiaoxi
    Xiao, Xin
    Liang, Yong
    Nan, Junmin
    MICROCHIMICA ACTA, 2013, 180 (5-6) : 477 - 483