Isothermal Microcalorimetry as a Tool for Studying Oxidation Stability of Insulating Liquids

被引:2
|
作者
Tronstad, Ingvild [1 ]
Blekkan, Edd A. [1 ]
Ese, Marit-Helen G. [2 ]
机构
[1] Norwegian Univ Sci & Technol NTNU, Dept Chem Engn, N-7491 Trondheim, Norway
[2] Sintef Energy Res, Dept Elect Power Technol, Trondheim, Norway
关键词
Dielectric liquids; calorimetry; power transformers; oxidation stability;
D O I
10.1109/TDEI.2012.6311497
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The application of an isothermal microcalorimeter for the investigation of the oxidation stability of insulating liquids has been studied. We propose that the total integral heat signal (area below the calorimeter curves) is a good indicator of the degree of oxidation taking place in the sample during the experiment. Known and unknown insulating liquids have been used in this study, and the amount of available oxygen in the samples has been varied. The results show that isothermal microcalorimetry is well suited for characterizing the oxidation stability of insulating liquids.
引用
收藏
页码:1528 / 1536
页数:9
相关论文
共 50 条
  • [21] Use of isothermal microcalorimetry for prediction of oxidative stability of several amino acids
    Roskar, R.
    Vivoda, M.
    Kmetec, V.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2008, 92 (03) : 791 - 794
  • [22] Thermal - Oxidation Stability of Insulating Fluids
    Semancik, P.
    Cimbala, R.
    Zalis, K.
    ACTA POLYTECHNICA, 2008, 48 (04) : 30 - 33
  • [23] Measuring antibiotic resistance in mixed cultures: Isothermal microcalorimetry as a novel analytical tool
    von Ah, Ueli
    Shani, Noam
    Chollet, Magali
    Solokhina, Anna
    Braissant, Olivier
    INTERNATIONAL DAIRY JOURNAL, 2018, 77 : 73 - 79
  • [24] Kinetic analysis on low-temperature oxidation of wood pellets by isothermal microcalorimetry
    Yao, Can
    Sheng, Changdong
    FIRE AND MATERIALS, 2025, 49 (01) : 116 - 124
  • [25] ELECTROHYDRODYNAMIC STABILITY OF INSULATING LIQUIDS SUBMITTED TO UNIPOLAR INJECTION
    ATTEN, P
    MOREAU, R
    JOURNAL DE MECANIQUE, 1972, 11 (03): : 471 - &
  • [26] Feasibility of using isothermal microcalorimetry to evaluate the physical stability of amorphous nifedipine and phenobarbital
    Aso, Y
    Yoshioka, S
    Kojima, S
    THERMOCHIMICA ACTA, 2001, 380 (02) : 199 - 204
  • [27] Compatibility and stability tests of risperidone with soft-drinks by isothermal titration microcalorimetry
    H. Aki
    Y. Okamoto
    T. Kimura
    Journal of Thermal Analysis and Calorimetry, 2006, 85 : 681 - 684
  • [28] Compatibility and stability tests of risperidone with soft-drinks by isothermal titration microcalorimetry
    Aki, H.
    Okamoto, Y.
    Kimura, T.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2006, 85 (03) : 681 - 684
  • [29] The CATBOOST as a tool to predict the isothermal compressibility of ionic liquids
    Postnikov, Eugene B.
    Jasiok, Bernadeta
    Chorazewski, Miroslaw
    JOURNAL OF MOLECULAR LIQUIDS, 2021, 333 (333)
  • [30] A novel isothermal microcalorimetry tool to assess drug effects on Ancylostoma ceylanicum and Necator americanus
    Flores, Dayana
    Panic, Gordana
    Braissant, Olivier
    Keiser, Jennifer
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2016, 100 (02) : 837 - 846