Evaluation of chemical cleaning efficiency of organic-fouled SWRO membrane by analyzing filtration resistance

被引:9
|
作者
Nam, Jong-Woo [1 ]
Hong, Sung-Ho [2 ]
Park, Jun-Young [1 ]
Park, Hyun-Sung [3 ]
Kim, Hyung-Soo [1 ]
Jang, Am [1 ]
机构
[1] Sungkyunkwan Univ, Dept Civil Architectural & Environm Syst Engn, Suwon, South Korea
[2] Cheil Ind Inc, Membrane Dev Grp, Uiwang Si, Gyeonggi Do, South Korea
[3] Mine Reclamat Corp, Inst Mine Reclamat Technol, Seoul 110727, South Korea
关键词
Chemical cleaning; Cleaning in place (CIP); Fouling; Reverse osmosis; Resistance; REVERSE-OSMOSIS MEMBRANES; NANOFILTRATION MEMBRANES; PLANTS;
D O I
10.1080/19443994.2013.780724
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Membrane fouling is an unavoidable phenomenon in the operation of seawater reverse osmosis and a major obstacle to economic and efficient operation. In particular, membrane fouling by organic matter negatively affects productivity, product quality, and process cost. Therefore, a chemical cleaning process is essential to prevent interruptions for an effective RO membrane filtration process. Firstly, this study focused on the proper chemical cleaning condition for commercial polyamide RO membranes purchased from two companies. The flux decline rate of SWC5+ membrane was higher than that of SW39HRLE400 membrane regardless of organic foulants because the initial zeta potential of SWC5+ membrane (-21.17mV) was lower than that of SW30HRLE400 membrane (-30.11mV) and the repulsive force between membrane surface and foulants was also lower. In addition, we attempted to evaluate cleaning efficiency according to the chemical cleaning conditions and investigate the cause of fouling by analyzing membrane resistance fraction after cleaning the organic-fouled membrane. As a result of cleaning in place (CIP), as the concentration and cleaning time increased when NaOH, trisodium phosphate 12, sodium tripolyphosphate, and ethylenediaminetetraacetic acid-4Na were used without sodium dodecylsulfate, cleaning efficiency increased significantly. Subsequently, in the condition of CIP using NaOH at pH 11 for 60min, the cleaning efficiency of membrane fouled by humic acid was higher that of membrane fouled by sodium alginate (SA) due to the strong interaction between hydrophobic membrane and hydrophobic foulants in the case of both membranes. To find the fouling rate and fouling cause, total resistance (R-t) was fractionated by the initial membrane resistance (R-m), resistance removed by flushing (R-c), resistance removed by CIP (R-a), and irreversible resistance (R-i). R-c and R-a in both membranes showed a similar proportion in R-t. The cause of fouling of the membrane fouled by SA was mainly the absorption of membrane surface, and that of membrane fouled by HA was the absorption of membrane surface and pore blocking by cake layer.
引用
收藏
页码:6172 / 6178
页数:7
相关论文
共 50 条
  • [41] Consecutive chemical cleaning of fouled PVC membrane using NaOH and ethanol during ultrafiltration of river water
    Tian, Jia-yu
    Chen, Zhong-lin
    Yang, Yan-ling
    Liang, Heng
    Nan, Jun
    Li, Gui-bai
    WATER RESEARCH, 2010, 44 (01) : 59 - 68
  • [42] Effects of Chemical Cleaning on the Ageing of Polyvinylidene Fluoride Microfiltration and Ultrafiltration Membranes Fouled with Organic and Inorganic Matter
    Chheang, Mariny
    Hongprasith, Narapong
    Ratanatawanate, Chalita
    Lohwacharin, Jenyuk
    MEMBRANES, 2022, 12 (03)
  • [43] Chemical cleaning of a tubular ceramic microfiltration membrane fouled with a whey protein concentrate suspension-Characterization of hydraulic and chemical cleanliness
    Blanpain-Avet, P.
    Migdal, J. F.
    Benezech, T.
    JOURNAL OF MEMBRANE SCIENCE, 2009, 337 (1-2) : 153 - 174
  • [44] Chemical cleaning effects on properties and separation efficiency of an RO membrane
    Tu, Kha L.
    Chivas, Allan R.
    Nghiem, Long D.
    MEMBRANE WATER TREATMENT, 2015, 6 (02) : 141 - 160
  • [45] EVALUATION OF CHEMICAL CLEANING - A KEY TO PLANT MAINTENANCE EFFICIENCY
    GALLINGE.CT
    MATERIALS PROTECTION, 1966, 5 (01): : 39 - &
  • [46] Physico-chemical pretreatment to seawater reverse osmosis (SWRO): organic characterization and membrane autopsy
    Shon, H. K.
    Vigneswaran, S.
    Zareie, M. H.
    Ben Aim, R.
    Lee, E.
    Lee, J.
    Cho, J.
    Kim, In S.
    DESALINATION, 2009, 236 (1-3) : 282 - 290
  • [47] Efficiency of various chemical cleanings for nanofiltration membrane fouled by conventionally-treated surface water
    Liikanen, R
    Yli-Kuivila, J
    Laukkanen, R
    JOURNAL OF MEMBRANE SCIENCE, 2002, 195 (02) : 265 - 276
  • [48] An impact of membrane resistance on the filtration efficiency at the protein fractionation along micro filtration modules
    Kuehnl, Wolfgang
    Piry, Alexander
    Kulozik, Ulrich
    CHEMIE INGENIEUR TECHNIK, 2008, 80 (08) : 1199 - 1205
  • [49] Chemical cleaning of algae-fouled ultrafiltration (UF) membrane by sodium hypochlorite (NaClO): Characterization of membrane and formation of halogenated by-products
    Ding, Jiaqi
    Wang, Songlin
    Xie, Pengchao
    Zou, Yujia
    Wan, Ying
    Chen, Yongsheng
    Wiesner, Mark R.
    JOURNAL OF MEMBRANE SCIENCE, 2020, 598
  • [50] Comparison of PES membrane chemical cleaning efficiency using different protocols
    Skorvan, O.
    Holba, M.
    Bodik, I.
    Mikulasek, P.
    EUROMEMBRANE CONFERENCE 2012, 2012, 44 : 1860 - 1863