Evaluation of chemical cleaning efficiency of organic-fouled SWRO membrane by analyzing filtration resistance

被引:9
|
作者
Nam, Jong-Woo [1 ]
Hong, Sung-Ho [2 ]
Park, Jun-Young [1 ]
Park, Hyun-Sung [3 ]
Kim, Hyung-Soo [1 ]
Jang, Am [1 ]
机构
[1] Sungkyunkwan Univ, Dept Civil Architectural & Environm Syst Engn, Suwon, South Korea
[2] Cheil Ind Inc, Membrane Dev Grp, Uiwang Si, Gyeonggi Do, South Korea
[3] Mine Reclamat Corp, Inst Mine Reclamat Technol, Seoul 110727, South Korea
关键词
Chemical cleaning; Cleaning in place (CIP); Fouling; Reverse osmosis; Resistance; REVERSE-OSMOSIS MEMBRANES; NANOFILTRATION MEMBRANES; PLANTS;
D O I
10.1080/19443994.2013.780724
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Membrane fouling is an unavoidable phenomenon in the operation of seawater reverse osmosis and a major obstacle to economic and efficient operation. In particular, membrane fouling by organic matter negatively affects productivity, product quality, and process cost. Therefore, a chemical cleaning process is essential to prevent interruptions for an effective RO membrane filtration process. Firstly, this study focused on the proper chemical cleaning condition for commercial polyamide RO membranes purchased from two companies. The flux decline rate of SWC5+ membrane was higher than that of SW39HRLE400 membrane regardless of organic foulants because the initial zeta potential of SWC5+ membrane (-21.17mV) was lower than that of SW30HRLE400 membrane (-30.11mV) and the repulsive force between membrane surface and foulants was also lower. In addition, we attempted to evaluate cleaning efficiency according to the chemical cleaning conditions and investigate the cause of fouling by analyzing membrane resistance fraction after cleaning the organic-fouled membrane. As a result of cleaning in place (CIP), as the concentration and cleaning time increased when NaOH, trisodium phosphate 12, sodium tripolyphosphate, and ethylenediaminetetraacetic acid-4Na were used without sodium dodecylsulfate, cleaning efficiency increased significantly. Subsequently, in the condition of CIP using NaOH at pH 11 for 60min, the cleaning efficiency of membrane fouled by humic acid was higher that of membrane fouled by sodium alginate (SA) due to the strong interaction between hydrophobic membrane and hydrophobic foulants in the case of both membranes. To find the fouling rate and fouling cause, total resistance (R-t) was fractionated by the initial membrane resistance (R-m), resistance removed by flushing (R-c), resistance removed by CIP (R-a), and irreversible resistance (R-i). R-c and R-a in both membranes showed a similar proportion in R-t. The cause of fouling of the membrane fouled by SA was mainly the absorption of membrane surface, and that of membrane fouled by HA was the absorption of membrane surface and pore blocking by cake layer.
引用
收藏
页码:6172 / 6178
页数:7
相关论文
共 50 条
  • [1] Chemical and physical aspects of cleaning of organic-fouled reverse osmosis membranes
    Ang, WS
    Lee, SY
    Elimelech, M
    JOURNAL OF MEMBRANE SCIENCE, 2006, 272 (1-2) : 198 - 210
  • [2] Chemical and physical aspects of chemical cleaning on organic-fouled reverse osmosis membranes.
    Ang, WS
    Lee, S
    Elimelech, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U633 - U633
  • [3] Salt cleaning of organic-fouled reverse osmosis membranes
    Lee, Sangyoup
    Elimelech, Menachem
    WATER RESEARCH, 2007, 41 (05) : 1134 - 1142
  • [4] Osmosis-assisted cleaning of organic-fouled seawater RO membranes
    Ramon, Guy Z.
    The-Vinh Nguyen
    Hoek, Eric M. V.
    CHEMICAL ENGINEERING JOURNAL, 2013, 218 : 173 - 182
  • [5] Osmosis-assisted cleaning of organic-fouled seawater RO membranes
    Hoek, E.M.V. (emvhoek@ucla.edu), 1600, Elsevier B.V., Netherlands (218):
  • [6] Intensified cleaning of organic-fouled reverse osmosis membranes by thermo-responsive polymer (TRP)
    Yu, Sanchuan
    Chen, Zhihai
    Liu, Jingqun
    Yao, Guohua
    Liu, Meihong
    Gao, Congjie
    JOURNAL OF MEMBRANE SCIENCE, 2012, 392 : 181 - 191
  • [7] Mitigation mechanisms of silica scaling on different organic-fouled nanofiltration membrane surface
    Wang, Jiaxuan
    Wang, Xinruo
    Liu, Zhe
    Sun, Peidong
    Hou, Yushi
    Wang, Na
    Wang, Lei
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2024, 686
  • [8] Osmotic backwashing of organic-fouled reverse osmosis membranes: Efficiency and implications for fouling control
    Ramon, Guy Z.
    Hoek, Eric M. V.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [9] Chemical cleaning of reverse osmosis membrane fouled by wastewater
    Madaeni, S. S.
    Samieirad, S.
    DESALINATION, 2010, 257 (1-3) : 80 - 86
  • [10] CHEMICAL CLEANING OF MICROFILTRATION CERAMIC MEMBRANE FOULED BY NOM
    Bazin, Maisarah Mohamed
    Nakamura, Yuzo
    Ahmad, Norhayati
    JURNAL TEKNOLOGI, 2018, 80 (06): : 95 - 103