Coexistence of coarctation of aorta and anomalies of aortic arch arteries on the basis of vascular examinations in 64-slice computed tomography

被引:0
|
作者
Glowacki, Jan [1 ]
Maslanka, Patrycja [2 ]
Miszalski-Jamka, Karol [1 ]
Szkutnik, Malgorzata [3 ]
Wasilewski, Jaroslaw [1 ]
Jarski, Piotr [1 ]
Bialkowski, Jacek [3 ]
机构
[1] Slaskie Ctr Chorob Serca, Pracownia Tomog Komputerowej, PL-41800 Zabrze, Poland
[2] Szpital Rejonowy, Zaklad Diagnostyki & Terapii, Raciborz, Poland
[3] Slaskie Ctr Chorob Serca, Oddzial Klin Wrodzonych Wad Serca & Kardiol Dziec, Zabrze, Poland
来源
KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA | 2008年 / 5卷 / 03期
关键词
aortic coarctation; aortic arch anomalies; multislice computed tomography;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Aortic coarctation is an aortic stenosis at the level of the isthmus, next to the ductus arteriosus or attachment of the ligament arteriosus, below the beginning of the left subclavian artery This defect occurs as an isolated stenosis or associated with other failures. Aim: The aim of the study was to compare the occurrence frequency of aortic coarctation and anomalies of aortic arch arteries. Material and Methods: Retrospective analysis included 53 patients with diagnosed coarctation of aorta with 64-slice CT in the Silesian Centre of Heart Diseases in the last 13 months. Results: The structure of aortic arch arteries was typical in 37 cases, brachio-cephalic trunk, left common carotid artery and left subclavian artery. Anomalies of aortic arch arteries were observed in 15 cases (28.85%). Conclusions: Multislice computed tomography proved to be very useful in the evaluation of coarctation and coexisting anatomic structures. A diagnostic examination can significantly influence the choice of treatment type (angioplasty, stenting, surgery); the analyses of CT examinations can indicate an increased frequency of the coexistence of aortic coarctation and anomalies of aortic arch arteries in comparison to normal aorta.
引用
收藏
页码:328 / 331
页数:4
相关论文
共 50 条
  • [21] Intimal flap movement in aortic Stanford type-A dissection visualized by 64-slice computed tomography
    Probst, Chris
    Schiller, Wolfgang
    Welz, Armin
    Kovacs, Attila
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 34 (02) : 452 - 452
  • [22] Gated cardiac imaging of the aortic valve on 64-slice multidetector row computed tomography: Preliminary observations
    Pannu, HK
    Jacobs, JE
    Lai, SH
    Fishman, EK
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (03) : 443 - 446
  • [23] Evaluation of coronary artery bypass grafts and native coronary arteries using 64-slice multidetector computed tomography
    Onuma, Yoshinobu
    Tanabe, Kengo
    Chihara, Ruri
    Yamamoto, Hirosada
    Miura, Yujiro
    Kigawa, Ikutaro
    Fukuda, Sachito
    Miyairi, Takeshi
    Nakajima, Hiroyoshi
    Hara, Kazuhiro
    AMERICAN HEART JOURNAL, 2007, 154 (03) : 519 - 526
  • [24] Prevalence and predictors of bridging of coronary arteries in a large Indonesian population, as detected by 64-slice computed tomography scan
    J. Wirianta
    M. Mouden
    J. P. Ottervanger
    J. R. Timmer
    Y. B. Juwana
    M.-J. de Boer
    H. Suryapranata
    Netherlands Heart Journal, 2012, 20 : 396 - 401
  • [25] Prevalence and predictors of bridging of coronary arteries in a large Indonesian population, as detected by 64-slice computed tomography scan
    Wirianta, J.
    Mouden, M.
    Ottervanger, J. P.
    Timmer, J. R.
    Juwana, Y. B.
    de Boer, M. -J.
    Suryapranata, H.
    NETHERLANDS HEART JOURNAL, 2012, 20 (10) : 396 - 401
  • [26] Accuracy of 64-slice computed tomography for the preoperative detection of coronary artery disease in patients with chronic aortic regurgitation
    Scheffel, Hans
    Leschka, Sebastian
    Plass, Andr
    Vachenauer, Robert
    Gaemperli, Oliver
    Garzoli, Elisabeth
    Genoni, Michele
    Marincek, Borut
    Kaufmann, Philipp
    Alkadhi, Hatem
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (04): : 701 - 706
  • [27] Diagnostic accuracy of 64-slice computed tomography for diagnosis of aortic regurgitation in patients referred to coronary CT angiography
    Feuchtner, Gudrun
    Friedrich, Guy
    Bonatti, Johannes
    Mueller, Silvana
    Schachner, Thomas
    Jodocy, Daniel
    Pachinger, Otmar
    Laufer, Guenther
    zur Nedden, Dieter
    Dichtl, Wolfgang
    CIRCULATION, 2007, 116 (16) : 410 - 410
  • [28] Papillary fibroelastoma of the aortic valve - Appearance in 64-slice spiral computed tomography, magnetic resonance imaging, and echocardiography
    Lembcke, Alexander
    Meyer, Rudolf
    Kivelitz, Dietmar
    Thiele, Holger
    Barho, Christian
    Albes, Johannes M.
    Hotz, Holger
    CIRCULATION, 2007, 115 (01) : E3 - E6
  • [29] Diagnostic accuracy of 64-slice multidetector computed tomography for the evaluation of aortic root in patients selected for transcatheter aortic valve implantation
    Pontone, G.
    Andreini, D.
    Bertella, E.
    Mushtaq, S.
    Annoni, A. D.
    Tamborini, G.
    Fusari, M.
    Ballerini, G.
    Bartorelli, A. L.
    Pepi, M.
    EUROPEAN HEART JOURNAL, 2010, 31 : 292 - 292
  • [30] Diagnostic accuracy of 64-slice multidetector computed tomography for the evaluation of aortic root in patients selected for transcatheter aortic valve implantation
    Pontone, G.
    Andreini, D.
    Bertella, E.
    Mushtaq, S.
    Annoni, A. D.
    Tamborini, G.
    Fusari, M.
    Ballerini, G.
    Bartorelli, A. L.
    Pepi, M.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A4 - A4